KEE GATE
20Pages

{{requestButtons}}

Catalog excerpts

KEE GATE - 1

Single and Double Gates Operation & Maintenance Manual

Open the catalog to page 1
KEE GATE - 2

System Overview SAFETY GATES KEE GATE is a complete range of safety gates designed specifically to provide permanent hazard protection for internal or external applications. KEE GATE can provide permanent protection for any openings, ladder/stair access points, roof hatches and restricted areas, where regular access for maintenance & inspection is required. The gates have been specifically designed to provide a “retro-fit” solution to existing fixed structures where opening protection is required. The U-bolt connection allows each gate to be connected to posts from 33.7 – 48.3mm (1” – 1.5”...

Open the catalog to page 2
KEE GATE - 3

System Overview TESTING & CERTIFICATION Tested in accordance with the following (See Specification Section for full details) :-EN 13374 Class A. EN ISO 14122 : 2016 Part 3 OSHA ANSI Ontario Building Code, NBC and British Columbia Building Code Canadian Standards Association Canada Occupational Health and Safety LIFE CYCLE TESTING - BS 6375-2:2009 Clause 6.5 - Opening and closing of Gate through 90 degrees. SALT SPRAY TESTING - ASTM B117 - 11 - 55 over 200 hours to assess performance of coating to resist corrosion. OFFICIAL DOCUMENTATION All Systems comply with the following:-Work at Height...

Open the catalog to page 3
KEE GATE - 4

Compliance PRODUCT SPECIFICATION – EUROPEAN – USA - CANADIAN FEATURES:- Spring Loaded, self-closing safety gate. GENERAL DOUBLE GATE LAYOUT EUROPE Recommended installed height of KEE GATE is 1.1m in Europe and Canada depending on the structure it is fixed to and National Regulations. Double gate width 900mm. Internal gap between top and bottom guardrail 634mm. Top rail to mid rail centre to centre 500mm. KEE GATE systems require physical fixing to the buildings structure. The complete system’s design, manufacture, testing and installation have been externally assessed and tested to European...

Open the catalog to page 4
KEE GATE - 5

Single Gate Components - Europe European Gate - Galvanised - SGEU600GV Spring Loaded, self-closing safety gate. Manufactured from steel to EN 10255. 33.7mm diameter tube x 3.2mm wall thickness to meet requirements of EN 13374 & EN 14122:2016. Complete with fixing pack. Material : Galvanised steel to BS EN ISO 1461. Net weight : 14kg (30lb 10oz). European Gate – Powder Coated - SGEU600PC Spring Loaded, self-closing safety gate. Manufactured from steel to EN 10255 33.7mm diameter tube x 3.2mm wall thickness to meet requirements of EN 13374 & EN 14122:2016. Complete with fixing pack. Powder...

Open the catalog to page 5
KEE GATE - 6

Single Gate Components - North America Powder Coated USA - AAMA 2603-2605 Galvanised Powder Coated SGNA030PC 30" Gate - Powder Coated Galvanised Powder Coated Galvanised Powder Coated

Open the catalog to page 6
KEE GATE - 7

Double Gate Components - Europe and North America European Double Gate - Galvanised - SGEUDP2GV SAFETY GATE EUROPEAN FIXING PACK 2 - SGEUFXPK2 Spring Loaded, self-closing safety gate. Manufactured from steel to EN 10255. 33.7mm diameter tube x 3.2mm wall thickness to meet requirements of EN 13374 & EN 14122:2016. Complete with fixing pack. Material : Galvanised steel to BS EN ISO 1461 ASTM A53. Net weight : 28kg (61lb 12oz). Supplied for the European market to fit posts 33.7mm, 42.4mm and 48.3 mm diameter. Fixing pack contains 3No. U Bolts for each size complete with M8 and M10 nuts and...

Open the catalog to page 7
KEE GATE - 8

Mounting and tensioning single gate spring TOOLS REQUIRED You will need the following in order to install the Kee Gate: • Marker Pen • Tape Measure • 1No 24mm Ring Spanner • 1No 13mm socket • 1No 17mm socket • 1No 24mm socket • 1No W Hex Key Socket • 1No 6mm Hex Key Socket • Torque Wrench 10- 60 Nm approx • Hacksaw or Similar • Small Magnetic Level A. Align the fixing plate on internal face of the opening, so B. Using a M8 or M10 flat washer and nut connect the U bolt to Mounting Gate to Upright Establish that the gate will close in direction of hazard!! Failure to do so could result in...

Open the catalog to page 8
KEE GATE - 9

Mounting and tensioning single gate spring F. To cut the gate to the correct size simply place a straight edge/magnetic level as shown and measure the distance to the point where the outside edge of the vertical tube meets the supporting structure as shown. (DO NOT CUT AT THIS MARK!) G. Disconnect the tubular gate from the hinge assembly by loosening the top & bottom cast clamp grub screw using a hex head socket as shown. H. Measure the distance recorded in point (f) and mark the gate top and bottom tubes and mid rail as shown. I. Using a hacksaw or similar, carefully cut through the top,...

Open the catalog to page 9
KEE GATE - 10

Mounting and tensioning single gate spring Caution! Over tensioning of the spring assembly will result in failure of the product!! L. Manually open the gate at 45 degrees from its closed position. O. Mount clamp on lower part of gate, just above the bend and insert mid rail. Use 6mm hex head socket to tighten supplied M10 bolts into coupling nut. M. Using the 24mm socket & ring spanner start to tighten the bolt until the gate completely closes. (Note:- You may have to hold the socket whilst using the ratchet). N. Once the gate is completely closed tighten the locking nut to hold the...

Open the catalog to page 10
KEE GATE - 11

Mounting and tensioning single gate spring Note:- Installing Kee Gate When installing Kee Gate on a pitched roof it is essential that the gate is mounted vertically level to the horizontal. This can be accommodated by using standard 90 degree Elbows (15-8) (4No required per gate). The elbows permit adjustment allowing the Kee Gate to be orientated to the correct angle. If the gate is not set at the correct angle the hinge cannot be tensioned correctly and the gate may not close as required.

Open the catalog to page 11
KEE GATE - 12

Mounting and tensioning single gate spring TOOLS REQUIRED You will need the following in order to install the Kee Gate: • Marker Pen • Tape Measure • 1 No 15/16” Ring Spanners • 3/16” Allen Key • 1 No %” socket • 1 No 11/16”socket • 1 No 15/16” socket • Torque Wrench 10- 60 Nm approx • Small Magnetic Level Mounting Gate to Upright Establish that the gate will close in direction of hazard!! Failure to do so could result in Death or serious injury. A. Align the fixing plate on internal face of the opening, so B. Using a 11/16” or V2" flat washer and nut connect the U bolt that the rails of...

Open the catalog to page 12

All KEE SAFETY catalogs and technical brochures

  1. Kee Lite

    2 Pages

  2. Kee Cover

    4 Pages

  3. KEE DOME

    2 Pages

  4. Kee i-bolt

    2 Pages

  5. Pallet Gates

    28 Pages

  6. Kee Modules

    1 Pages

  7. Kee Anchor

    3 Pages