COMBILINE
28Pages

{{requestButtons}}

Catalog excerpts

COMBILINE - 2

Introduction Mains EMC compatibility Mains chokes Harmonic filters Standard HF filters Low-leakage current IT-HF filters Central HF filters, E6 series Comprehensive EMC services Motor chokes Sinusoidal filters NHF-filters I/O-filtesr

Open the catalog to page 2
COMBILINE - 3

SYSTEM OVERVIEW Automation with Drive stands as a synonym for optimally selected combinations of control and automation solutions with the drive level at the end it is the key to ­successful machine concepts. Let the following pages inspire you with regards to the diversity and ­performance of the EMC COMBILINE, and help you to find a solution that reliably meets your requirements. SOFTWARE COMBIVIS studio HMI COMBIVIS studio 6 COMBIVIS connect COMBIVIS studio HMI COMBIVIS studio 6 COMBIVIS connect CONNECT ROUTER RESET RUN / STOP COM Rx CONNECT ROUTER RESET POWER REMOTE CONNECT COM Tx Input...

Open the catalog to page 3
COMBILINE - 4

EMC COMPATIBILITY plays an important role in the operating safety of machines and equipment. Manufacturers and operators are required to implement the installed systems so as to achieve electrical compliance with the limits (for emissions) and requirements (for fault-free operations) set out in the standards and regulations! To this end, the following standards must be applied as per the order below: Product standard: This standard applies to an exactly defined application area that generally meets the special requirements of a product family. Example: The so-called „power drives systems"...

Open the catalog to page 4
COMBILINE - 5

FILTERS AND CHOKES The operation of variable-speed drives with intermediate voltage circuits puts stress on the mains and motor, which can be optimised with the following additional measures (depending on the place of use and type of application): MAINS  Mains chokes reduce harmonics and in-rush current to the mains and increase the service life of components in the devices.  Harmonics filters reduce the harmonics resulting in sinusoidal current consumption without the voltage losses that occur with mains chokes. • HF filters for high-frequency interference suppression of single and...

Open the catalog to page 5
COMBILINE - 6

MAINS CHOKES optimise the harmonics to the mains power supply which result from the pulse-shaped charging of uncontrolled rectifiers and reduce the effective input current. This decrease in stress has the direct effect of significantly increasing the service life of the link voltage capacitors in inverters and servo drives and reducing the stress on the input rectifier. Chokes for 1-phase or 3-phase units are universally designed for a frequency range of 45 - 65 Hz. Nominal inductance is determined by the 4 % short circuit voltage at nominal current and frequency. With respect to the...

Open the catalog to page 6
COMBILINE - 7

MAINS CHOKES KEB MAINS CHOKE 3-PHASES 400 V AC (U = 550 V), 50/60 Hz ' max ”

Open the catalog to page 7
COMBILINE - 8

COMBILINE MAINS-SIDE EN 61000-3-4 G5/4 Engineering Recommendation (GB) COP, supply rules (Hong Kong) EN 61000-3-12; 16 A up to 75 A EN 12015 (Standard for lifts, escalators and passenger conveyors, Europe) • Quality of Electric Energy Supply, Harmonics in Public Supply Network (China)

Open the catalog to page 8
COMBILINE - 9

HARMONIC FILTER KEB HARMONIC FILTER 3-PHASES 400 V AC (Umax = 440 V), 50 Hz - THDI < 15 % / PWHD < 39 %

Open the catalog to page 9
COMBILINE - 10

COMBILINE MAINS-SIDE STANDARD HF-FILTER are filters which are installed on the mains side for the purpose of complying with statutory limits for mains-bound high-frequency interference. The filters consist of an LC grid which ensures maximum mismatch between the high-frequency interference source and the mains. Mechanically adapted for the COMBIVERT F5 frequency inverters, these filters have been designed for mains-side interference suppression with especially high attenuation over a wide frequency range. These all-purpose filters can be used with all available switching frequencies. They...

Open the catalog to page 10
COMBILINE - 11

znnm EMC-FILTER 1-PHASE 230 V AC (Umax = 264 V), 50/60 Hz ±10 %

Open the catalog to page 11
COMBILINE - 12

COMBILINE MAINS-SIDE LOW-LEAKAGE CURRENT IT-HF FILTERS In insulated grids, insulation resistance is continuously monitored against ground. During this monitoring process, the discharge resistors used in the filters falsify this measurement and they must be suppressed during normal operations. The space-saving IT-HF filters meet this requirement internally and also offer small leakage currents in addition to providing the appropriate damping. The enclosure design has been implemented so as to be compatible with the COMBIVERT F5 inverters, depending on its function as a footprint or...

Open the catalog to page 12
COMBILINE - 13

RADIO INTERFERENCE SUPPRESSION FILTERS ENCLOSURE SYSTEM FOR COMBIVERT F5 The mechanical configuration of the HF filters has been designed for minimal space requirements in the switch cabinet and directly optimised for the enclosure design of the COMBIVERT F5 inverter and servo drive series. Mechanical designs configured as footprint versions also offer directly mountable enclosures for powers up to 75 kW, which require no or only minimally larger areas on the mounting plate and provide extensive ground connections with the accessory kit for the shield clamps. More extensive enclosure...

Open the catalog to page 13
COMBILINE - 14

CENTRAL HF FILTERS, E6 SERIES The E6 high-frequency (HF) filter can be used as central switch cabinet filters, collection filters and for the suppression of individual devices. • Large rated voltage range 0 - 550 V. • Rated currents from 12 - 330 A, in eight sizes. • Compact design in book form with small footprint. • High saturation resistance. Shielded motor cable lengths up to 100 m and 500 m. • An especially wide damping area due to newly developed filter components. • With respect to operations with frequency inverters, the filters have been designed for a low leakage current. With the...

Open the catalog to page 14
COMBILINE - 15

CENTRAL HF FILTERS, E6 SERIES THREE-WIRE HF-FILTER 3-PHASES 400/480 V AC (Umax = 550 V), 50/60 Hz ± 10 % IN [A] 12 22 43 65 100 150 200 330 FOUR-WIRE HF-FILTER 3-PHASES 400/480 V AC (Umax = 550 V), 50/60 Hz ± 10 % IN [A] 22 43 65 100 150 Scan Graph dBµV 80.0 AC/DC sensitive RCCB (residential current circuit breaker) Comparison leakage currents

Open the catalog to page 15
COMBILINE - 16

COMBILINE ADVISORY AND TESTING KEB PROVIDES SECURITY! DRIVES, EMC ADVISORY AND EMC FILTERS WITH DELIVERIES FROM ONE SOURCE. EC DIRECTIVE 2004/108/EC requires all equipment manufacturers to design the installation of electrical systems in compliance with EMC legislation. In many cases, this means that individual CE-labelled components must be inspected for their interaction in the equipment or machine. For this purpose, KEB offers a service that includes advisory services and the testing of electrical equipment. Our extensive experience in the development and application of drive controllers...

Open the catalog to page 16

All KEB Automation KG catalogs and technical brochures

  1. COMBIVERT F6

    18 Pages

  2. 13F6A12-3A11

    1 Pages

  3. 12F6K1D-3AMA

    1 Pages

  4. 12F6A12-3A11

    1 Pages

  5. MP IE4 MOTORS

    44 Pages

  6. C6 ROUTER

    10 Pages

  7. I/O System

    19 Pages

  8. C6 AMM

    6 Pages

  9. C6 Monitor

    6 Pages

  10. C6 P34 BM

    6 Pages

  11. C6 E22 BM

    6 Pages

  12. C6 P34 Box

    6 Pages

  13. C6 E22 Box

    6 Pages

  14. C6 P34 Panel

    6 Pages

  15. C6 E22

    6 Pages

  16. C6 SMART

    6 Pages

  17. C6 COMPACT

    6 Pages

  18. C6 S14

    6 Pages

  19. C6 HMI-LC

    6 Pages

  20. C6 HMI

    6 Pages

  21. COMBIVERT F6-K

    12 Pages

  22. Servo Motors

    16 Pages

  23. COMBIVERT R6

    8 Pages

  24. COMBIVERT F5

    32 Pages

  25. COMBIVERT G6

    16 Pages

  26. COMBIVERT H6

    24 Pages

  27. COMBIVERT F6

    16 Pages

  28. COMBIVERT S6

    24 Pages

  29. KEB DRIVE

    130 Pages

Archived catalogs