Industrial Products Size 5, 10 up to 315 bar up to 50 L/min Flow Valves Flow Control Valve Two-Way Compensated Type FJC, Series 10 Data Sheet F-1003/06.99 GB Features ◊ Thin blade orifice for accurate temperature compensation. ◊ Stroke limiter can be mounted to stop jumping at start up (optional). ◊ Check valve (optional). ◊ Large selection of maximum flow rates to enable optimum control. ◊ Rotary knob with scale. ◊ Rotary adjusting knob has a lock to stop accidental adjustment. ◊ Porting pattern to din 24340, form G, ISO 6263 and CETOP-RP 121 H. Functional Description (FJC5P-10-3-10Q-V) Type FJC Series 10 Flow Control Valves are used to maintain a constant flow independent of pressure and temperature. Type FJC The valves primarily comprises a housing (1), a setting element (2), an orifice (3), a pressure compensator (4) and a check valve (5). Flow from port A to B is passed through throttle orifice (6) which can be varied by turning the setting element (2). 2 With no flow through the valve, the pressure compensator (4) is kept in the open position by the spring (7). When the fluid flows through the valve, the pressure at the downstream of the throttle position (3) is applied to the spring chamber of the pressure compensator (4) and the pressure at the upstream is applied to the opposite side. 7 1 4 6 5 The pressure compensator (4) moves into the compensating position until the forces balance. As a result the pressure differential between the upstream and the downstream of the throttle position is kept constant, i.e. the flow through the valve is constant. 3 Flow from Port B to A is passed through the check valve(s) freely. Model FJC Page 1.6 A Data Sheet F-1003/06.99 B

Open the catalog to page 1
T - Throttle Valve Pipe Fitting - 2

Flow Valves Industrial Products Ordering Code - Flow Control Valve Flow Control Valve Series Number 3: Lockable Rotary Knob W: Fatty Acid Ester, Water Glycol Pressure Compensator Stroke Limiter No Code: Without pressure compensator stroke limiter. J: With pressure compensator stroke limiter. Maximum Controlled Flow Capacity Data Sheet Hydraulic Products

Open the catalog to page 2
T - Throttle Valve Pipe Fitting - 3

Industrial Products Flow Valves Technical Data For applications outside the following parameters, please consult Kawasaki Precision Machinery (UK) Ltd. Pressure Fluid Mineral oil, phosphate ester, fatty acid ester and water glycol. Phosphate ester is only suitable for use with FPM seals. Pressure Fluid Temperature Range -20°C to +70°C Ambient Temperature Range -30°C to +50°C Degree of Contamination Maximum permissible degree of contamination of fluid is to NAS 1638 Class 9. Kawasaki recommend a filter with a rentention rate of ß10 ≥ 75. Viscosity Range 2.8 to 380cSt Max. Operating Pressure...

Open the catalog to page 3
T - Throttle Valve Pipe Fitting - 4

Flow Valves Industrial Products

Open the catalog to page 4

All Kawasaki Precision Machinery catalogs and technical brochures

  1. HPB Series

    76 Pages

  2. M3X/M3B

    35 Pages

  3. HPC Series

    37 Pages

  4. HMC Series

    43 Pages

  5. K3V/K5V/K7V

    8 Pages

  6. HMB Series

    92 Pages

  7. K3VL Series

    76 Pages

  8. PV series

    2 Pages

  9. ERU series

    2 Pages

  10. HMF Series

    72 Pages

  11. HPC Series

    37 Pages

  12. KPM-PV

    2 Pages

  13. K3VL Series

    72 Pages

  14. HMF Series

    72 Pages

  15. KMP series

    2 Pages

  16. ERU series

    2 Pages

  17. K7VG

    32 Pages

  18. K8V

    36 Pages

  19. K3VLS

    36 Pages

  20. KLSV 18

    24 Pages

  21. KPES

    2 Pages

  22. HPC400

    4 Pages

  23. M-Motor

    35 Pages

  24. K3VG Series

    34 Pages

Archived catalogs

  1. HMB

    70 Pages

  2. HMC CATALOGUE

    60 Pages