9.11/4
KALLER
Step 6 Bleeding the Power Unit
Pump until the oil pressure is 50 bar, open the valve (9) and bleed the Power Unit. Close the valve (9). Repeat this until the oil is free from air bubbles.
Step 7 air
Check that the oil is free from
First make sure that the oil pressure is 0 bar, ie. pressureless. Try to push the piston down by hand. If it is possible to push it down a little there is some air left in the system. Repeat step 5 and 6 until the oil is totally free from air or the piston can not be moved.
A
Step 8 Check for any leakage
APump until oil pressure is 50 bar and look for any leakage from the adapters and the units. Make sure that the oil pressure is 0 bar by opening the bleed valve (9).
111 Step 9 Disconnect the pump unit
Uncouple the oil filling armature and the transparent hose. Fit the plug on the top of the Power Cylinder by using the hook spanner to hold the piston. Tighten the bleed valve on the Cam Unit/ Force Cylinder and clean the area.
Step 10 Charge the Accumulator with nitrogen
After the oil filling procedure, the Accumulator has to be charged with nitrogen up to 150 bar or to the required gas pressure for the operation. Maximum pressure is 180 bar. See also page 9.7/2.
The system is now ready for operation.
9^ ^ MM ^^^^.^B^J^mu^mmMMm^Lm^Lm^^^L\ We reserve the right to add, delete or modify
■ 11/4 components without notification.
Edition 7 / May 2007 bY Stromsholmen AB
+46 140 571 00»www.kaller.com