06.04.201_Maxi-M-8-30 - 1

Industrial motor controller for brushed DC motors 24 VDC Design for output currents up to 8 A Control with the following functions: - overload shut-down - short circuit detection - dynamic brake To snap onto the DIN rail EN 50022 Unit width: 22,5 mm Control inputs Quiescent current Technical data: load circuit 09.01.2020 KL - Errors and technical modification subject to change. All rights reserved. KALEJA GmbH Strubelweg 14 D-73553 Alfdorf Tel.: +49 7172 93711 0 info@kaleia.com

Open the catalog to page 1
06.04.201_Maxi-M-8-30 - 2

Housing, terminal, printed circuit board _UL94-HB The module MAXI-M-8-30 is a one-quadrant DC motor control for use in an industrial environment. It guarantees the switching on and off of motors. The motor stops always with dynamic braking. | Typical applications: "" 09.01.2020 KL - Errors and technical modification subject to change. All rights reserved. © KALEJA GmbH

Open the catalog to page 2
06.04.201_Maxi-M-8-30 - 3

| Overload/over temperature switch off | Continuous load current / total current When operating one motor, the continuous load current specified in the technical data applies. When operating 2 motors the total current depends on various factors that must be determined depending on the application. E.g.: ambient temperature, duty cycle, installation situation. The maximum specified total current must not be exceeded. The device has an integrated overload and over temperature detection. If an event occurs, the motor will be switched off. After cooling down of the device the motor restarts...

Open the catalog to page 3
06.04.201_Maxi-M-8-30 - 4

Datasheet MAXI-M-8-30 06.04.201 Safety notes Maximum operational data The maximum operating data may not be exceeded. Installation The installation and start-up must be performed by specialist personnel exclusively. All affected components must be disconnected from the mains. Start-up For the first start-up, the motor should be operated without load. Risk of death Do not touch live parts after switching on! The assembly must be operated exclusively on safety extra-low voltage. With operation on extra-low voltage (e.g. via autotransformer), death or injury can occur. Fire protection The...

Open the catalog to page 4

All KALEJA GmbH catalogs and technical brochures

  1. M-MWS-6-30

    1 Pages

  2. M-MRI-3-30

    2 Pages

  3. M-BL-5-30

    2 Pages

  4. M-MZ-4-30

    2 Pages

  5. Maxi-1Q-4-30

    2 Pages

  6. M-1Q-6-30

    2 Pages

  7. M-4Q-6-30

    2 Pages

  8. M-2Q-6-30

    2 Pages

  9. M-S-6-30

    2 Pages

  10. Maxi-S-4-30

    2 Pages

  11. MAXI-MW-8-30

    4 Pages

  12. M2-MR-5-30

    6 Pages

  13. 06.04.202

    4 Pages

  14. M2-3DR-5-30

    8 Pages

  15. M2-MWS-6-30

    7 Pages

  16. M2-MWI-6-30

    7 Pages

  17. M3-2QB-5-12

    7 Pages

  18. M3-4Q-5-30

    7 Pages

  19. Maxi-IM-5-60

    3 Pages

  20. MB-12

    1 Pages

  21. USV-S-9-B

    1 Pages

  22. USV-S-25-S

    1 Pages

  23. M3-2QB-5-30

    7 Pages

  24. M2-MWT-6-30

    7 Pages

  25. 06.34.008

    2 Pages

  26. 06.04.032

    2 Pages

  27. 06.34.006

    7 Pages

  28. 06.34.002

    6 Pages

  29. 01.01.212

    1 Pages

  30. 01.01.213

    1 Pages

  31. 02.01.104

    1 Pages

  32. 02.01.116

    1 Pages

  33. 02.01.117

    1 Pages

  34. 02.01.130

    1 Pages

  35. 02.03.226

    1 Pages

  36. 02.06.201

    1 Pages

  37. 04.08.001

    1 Pages

  38. 06.04.007

    2 Pages

  39. 06.04.008

    2 Pages

  40. 06.04.012

    1 Pages

  41. 06.04.014

    1 Pages

  42. 06.04.016

    2 Pages

  43. 06.04.019

    2 Pages

  44. 06.04.021

    2 Pages

  45. 06.04.025

    2 Pages

  46. 06.04.031

    2 Pages

  47. 06.04.039

    2 Pages

  48. 06.04.046

    2 Pages

  49. 06.04.048

    2 Pages

  50. 06.04.049

    2 Pages

  51. 06.04.051

    2 Pages

  52. 06.04.054

    2 Pages

  53. 06.04.056

    2 Pages

  54. 06.04.059

    2 Pages

  55. 06.04.066

    2 Pages

  56. 06.04.075

    2 Pages

  57. 06.04.078

    1 Pages

  58. 06.04.083

    2 Pages

  59. 06.04.085

    2 Pages

  60. 06.04.093

    2 Pages

  61. 06.34.001

    5 Pages

  62. 01.01.012

    1 Pages

  63. 01.01.011E

    1 Pages

  64. 01.01.007

    1 Pages