Desiccant dryers DC series - 7 Pages

  1. P. 1

  2. P. 2

  3. P. 3

  4. P. 4

  5. P. 5

  6. P. 6

  7. P. 7

Catalogue excerpts

Desiccant Dryers DC Series (Heatless regenerated) – Air flow rates 0.15 to 154.53 m³/min www.kaeser.com

 Open the catalogue to page 1

Pre-filter Inlet valve Desiccant tank Desiccant Check valve, Regulating valve (not visible) Desiccant tank Dust filter 1 2 3 4 5 6 7 1 2 3 4 5 6 7 Why is it necessary to dry compressed air? The atmospheric air drawn into a compressor is a mixture of gases that always contains water vapour. However, the amount of water vapour that air can carry depends on the temperature. As air temperature rises – as happens during compression – the air's capability to hold moisture increases also. When the air is cooled, its capacity to hold moisture reduces which causes the water vapour to condense. This condensate...

 Open the catalogue to page 2

– – – – – – Compact design with impressive performance DC 1.5 to 7.5 Compact and reliable With space saving design and easy installation, small DC desiccant dryers from KAESER provide outstanding performance and efficiency. They are constructed from components of the highest quality and sustain dependable low-pressure dew point performance even with continuous operation. As with all KAESER desiccant dryers, compact DC units operate in long, energy-saving cycles that are gentle on components and consequently require little maintenance. Furthermore, their high efficiency design ensures minimal purge...

 Open the catalogue to page 3

DC133: A saving of nearly 50 % of the investment cost through a 5 % saving in purge air. Compared with a model requiring 18.5 % purge air Compared with a model requiring 16.5 % purge air 100,000 € 10,000 € 1,000 € 100 € DC Series – Powerful, Compact and Reliable DC 12 to 1545 Minimal Operating and Service Costs As with the smaller DC desiccant dryers from KAESER KOMPRESSOREN, compact and large desiccant dryer models alike are also easy to transport, simple to install and provide outstanding performance. Meticulous design and high quality durable components ensure minimal operating and service...

 Open the catalogue to page 4

www.kaeser.com ECO CONTROL p3 p1 p2 V V V V V V V V www.kaeser.com ECO CONTROL p3 p1 p2 www.kaeser.com ECO CONTROL p3 p1 p2 www.kaeser.com ECO CONTROL p3 p1 p2 www.kaeser.com ECO CONTROL BASIC ISO CLASS 1 2 3 4 -94°F -40°F -4°F +38°F -70°C -40°C -20°C +3°C 30% 40% 50% 60% 70% 80% 90% V max 100% V min KW - + p3 p1 p2 ECO CONTROL Efficient – Service-friendly – Versatile A choice of two demand-oriented, energy-saving control systems is available for DC 12 dryer models upwards. As you might expect from KAESER products, each features a user-friendly control panel that combines comprehensive functionality...

 Open the catalogue to page 5

H H W W D D W H D DC 1.5 (E) 0.15 R 3/8 37 796 x 778 x 170 50 DC 2.8 (E) 0.28 R 3/8 54 796 x 778 x 170 50 DC 4.2 (E) 0.42 R 3/8 62 796 x 778 x 170 50 DC 5.8 (E) 0.58 R 3/8 78 792 x 930 x 217 50 DC 7.5 (E) 0.75 R 1/2 89 792 x 930 x 217 50 DC 12 (E) 1.2 R 1/2 165 2000 x 800 x 800 202 2000 x 800 x 800 50 DC 18 (E) 1.8 R 3/4 210 2000 x 800 x 800 247 2000 x 800 x 800 50 DC 27 (E) 2.7 R 3/4 260 2000 x 800 x 800 297 2000 x 800 x 800 50 DC 33 (E) 3.3 R 1 310 2000 x 1200 x 800 354 2000 x 1200 x 800 50 DC 50 (E) 5.0 R 1 320 2000 x 1200 x 800 364 2000 x 1200 x 800 50 DC 75 (E) 7.5 R 1 1/2 460 2000 x 1200...

 Open the catalogue to page 6

Diff erent applications require diff erent grades of air treatment Choose the required grade of treatment according to your fi eld of application: Compressed air treatment with a desiccant dryer (down to -70 °C pressure dew point) Explanation: THNF = bag filter Cleans dusty intake air to the compressor room ZK = Centrifugal separator Separates accumulating condensate ED = Eco Drain Electronic level-controlled condensate drain FB = Pre-filter + Solids – + Water/Condensate – + Oil – + Bacteria – Contaminants: Pharmaceuticals, dairies, breweries Solids Water Oil Bacteria Microchip production, optics,...

 Open the catalogue to page 7

All KAESER catalogues and technical brochures

  1. HPC plc

    7 Pages

    En
  2. breaker

    1 Pages

    En
  3. Genuine

    3 Pages

    En
  4. MOBILAIR 50

    3 Pages

    En
  5. Air receivers

    7 Pages

    En
  6. PREMIUM series

    8 Pages

    En
  7. Current issue

    17 Pages

    En
  8. Omega

    7 Pages

    En
  9. BB – HB series

    13 Pages

    En
  10. Compact series

    5 Pages

    En
  11. Air receivers

    3 Pages

    En
  12. Dental series

    5 Pages

    En
  13. Boosters series

    5 Pages

    En
  14. EUROCOMP series

    5 Pages

    En
  15. PREMIUM series

    8 Pages

    En
  16. CLASSIC series

    6 Pages

    En

Archived catalogues