TX Series Thermal Dispersion Flow / Level / Temperature Switch (Standard Response) - K-TEK - #2

/ 2


catalogue search
P. 01
P. 02
Pages:


See other catalogues for K-TEK

Text version of the page
Optional Configurations:
• REMOTE MOUNTING
The electronics can be remote mounted in applications where high temperature, high vibration, or access to switch point adjustment is needed. Distances up to 2000' can be specified.
• EXTENDED SENSOR
For larger line sizes the TX, TQ or TS user can specify a custom insertion length to any dimension, placement of the sensor 1/3 of the way into the line is ideal in most applications.
• DUAL SWITCHBOARD OPTION All Thermal Dispersion series switches can be configured, with an additional board, to function as a window comparator. The switch can detect between two different flow rates, two different tempera­tures, flow rate and temperature, or can monitor for a combination of temperature and level.
• FLANGE MOUNTING
This option is available on the TX and TQ Series in many different sizes, ratings and face configurations. The sensor insertion length is custom specified by the user.
• HIGH FLOW OPTION
By placing a shroud over the sensor head, the desired set-point of the instrument is extended to higher flow rates. This option is recommended in clean liquids and gases.
Process Capabilities:
• Full Vacuum to 10,000 PSIG (690bar)
• -320 to 900°F / -195 to 482°C
• Any Dielectric
• Any Specific Gravity
The TX, TQ, and TS Switches are Field Selectable for:
• Gas Flow
• Liquid Flow
• Temperature
• Liquid Level
- Adjustable for: Total Level Interface Level Foam Level
Liquid Solid Interface
• Solids Level
Available Materials:
• 316 / 316L SS
• Alloy 20
• Hastelloy C-276
• Titanium
• Mechanical or electro-polished 316 SS for sanitary & high purity service
• Other materials:
- Consult factory
Industries:
• Petrochemical
• Oil and Gas
• Power Utilities
• Pharmaceutical
• Food and Beverage
• Ships / Marine
• Biotechnology
K-TEK Thermal Dispersion Switches for Flow / Level / Temperature Applications
Typical Flow Applications for Thermal Dispersion Switches
• Pump Protection — Automatic shut-off on low/no flow
• Bearing Lubrication — Detects loss of lubricant flow
• Seal Leakage — Verifies positive seal flow or detects excessive leakage indicating maintenance required
• Energy Management — Pump shut-off on loss of
product to conserve energy
• Chemical Feed — Indicates low/no flow of chemical additives to process
• Metering Pumps — Senses loss of product flow avoiding incorrect measurement
tx series -STANDARD
flow I level I TEMPERATURE switch
• One Switch for Gas or Liquid Flow, Liquid Level, Interface Level, Temperature, or Granular Solids
• No moving parts
• Type 316L Stainless Steel, welded (std)
• Explosion-proof
• Exotic alloys for corrosive applications
• Temperature Range -320°F to +900°F / -195°C to 482°C
• Pressures to 10,000 PSIG / 690bar
Our standard flow/level/temperature switches are the most durable instruments available. They are ideally suited for detecting the increase or decrease in flow or level of virtually all liquids, gases, slurries and granular solids. The "no moving parts" principle of operation offers extremely reliable and repeatable operation with no vanes or linkage to stick, and no paddles to break off. This series of flow switches offers simple, reliable, and cost effective operation in the most severe industrial applications.
A wide selection of threaded and flanged process connections is available and probe length can be made to customer specified length. Numerous circuit board options are available.
ts series - SANITARY FLOW / LEVEL / TEMPERATURE SWITCH
• One Switch for Gas or Liquid Flow, Liquid Level, Interface Level, Temperature, or Granular Solids
• Designed to 3A requirements
• Type 316L Stainless Steel, welded (std)
• Temperature Range -50°F to +350°F / -45°C to 117°C
• Pressures to 500 PSIG / 34.5bar
• Simple, reliable, cost effective
The TS Series flow/level/temperature switch is designed to provide reliable detection in the food and pharmaceutical industries. These highly polished instruments, featuring quick disconnect fittings, can be used to detect the increases or decreases of flow, level or temperature in virtually all liquids, gases, slurries and granular solids.
ix series
IN-LINE FLOW / TEMPERATURE SWITCH
im series
LOW-COST IN LINE FLOW / TEMPERATURE SWITCH
Control Rooms — Verifies flow when pumps or valves are energized
Purge Air — Detects loss of flow for process or Plant safety
Safety Shower — Indicates Safety Shower use and potential danger to Plant personnel
Analyzer/Gas Chromatograph — Proves
continuous sample flow to instruments
Spray Nozzles — Detects nozzle blockage in paint or paper coating equipment
Relief Valve/Rupture Disc — Alarms on flow
or leakage of valve or rupture discs
tq series -FAST RESPONSE
flow I level I TEMPERATURE switch
• One Switch for Gas or Liquid Flow, Liquid Level, Interface Level, Temperature, or Granular Solids
• No moving parts
• Response time from 1 second
• Type 316L Stainless Steel
• Temperature Range -50°F to +350°F / -45°C to 117°C
• Pressures to 2000 PSIG / 138bar
• Explosion-proof
CONVERSION TABLE
These fast response flow/level/temperature switches are used when the response time in detecting the increase or decrease of flow or level is critical. With no moving parts exposed to the process they will provide extremely reliable and repeatable operation in virtually all liquids, gases, slurries, and
granular solids.
The QX Series has a wide selection of threaded and flanged process connections with customer selectable probe length. The varied electronic circuit board options offer the user a wide selection of power inputs and relay outputs.
Volumetric (G.P.M. Or C.F.M.) to Velocity (F.P.S.)
Response time from 1 second
316L Stainless Steel, (std), wetted parts
Explosion proof enclosure optional
Pressures to 4,000 PSIG / 276bar
Temperature Range
-50°F to +350°F / -45°C to 117°C)
LINE SIZE
1/0"
1/4"
3/0"
1/2"
3/4"
1"
1-1/4"
1-1/2"
Liquid Multiplia
3.08
1.68
1.06
0.37'
0.215
0.158
5.65
0.602
23.06
42.19
12.57
1.61
1.18
7.909
4.5
2.776
Gas Multiplier
• Response time from 1 second
• 316L Stainless Steel, (std), wetted parts
• Explosion proof
• Pressures to 10,000 PSIG / 690bar
• Temperature Range
50°F to +350°F / -46°C to 177°C
The IX Series is ideally suited for applications such as chemical injection, cooling lines, sampling lines, lubrication and other smaller flow rate situations.
LINE SIZE
2"
2-1/2"
3"
3-1/2"
4"
5"
6"
0"
Liquid Multiplier
Gas Multiplier
0.0434
0.0325
0.016
0.0111
0.0252
0.006
0.0956
0.067
CONVERSION CHART
TO cc / sec or ml / sec
From:
Multiply by:
From:
Multiply by:
Gal. / Min.
63.1
L/ Hr.
.278
Gal. / Hr.
1.05
L/ Day
0.0116
Gal. / Day
0.0438
Ft3 / Min.
472.0
L/ Min.
16.7
M3/ Hr.
278.0
0.7161
0.519
0.3248
0.2427
0.1884
0.12
0.083
0.048
10"
12"
14"
16"
10"
20"
24"
LINE SIZE
Liquid Multiplier
0.00237
0.001815
0.001434
0.001154
0.00407
0.00287
0.000798
0.0304
0.0177
0.0136
0.0107
0.00863
0.0209
0.00597
Gas Multiplier
EXAMPLES:
Example 1: 100 CFM in 4" line = 100 x .1004 = 10.04 F.P.S. Example 2: 10 G.P.M. in 3" line = 10 x .0434 = .434 F.P.S.
Test Conditions: 60°F, 14.7PSIA, SCH. 40 LINE
INSTRUMENT RANGEABILITY: IX & IM SERIES
PED CERTIFIED
ISO 9001 REGISTERED FIRM
WATER
0539 0036 ATEX Certified
OIL
AIR
Chiller Protection — Automatically turns off chiller at no flow to prevent compressor failure due to slugging
Heater Burn-out Prevention — Heater shut-down on
loss of flow to prevent overheating elements
Tank Car Loading — Senses dry line or phase change from liquid to nitrogen gas flow
Drain Line Sensor — Capable of detecting flow in partially filled lines
Energy Management — Turns off pumps, heaters, chillers, heat exchanger on loss of flow
Agitation Monitor — Positive indication of agitation in vessels
Factory Mutual System
ASME
1.0
10
100
1,000
10,000
(g
Range Tube #1 IX / 1875
Range Tube #2
IX / 2575
IX / 7575
IM / 2525
Flow Rate
cc / sec or ml / sec
CSA

pageCatalog pdf di En 2012-05-21-24