| | | Optional Configurations: REMOTE MOUNTING The electronics can be remote mounted in applications where high temperature, high vibration, or access to switch point adjustment is needed. Distances up to 2000' can be specified. EXTENDED SENSOR For larger line sizes the TX, TQ or TS user can specify a custom insertion length to any dimension, placement of the sensor 1/3 of the way into the line is ideal in most applications. DUAL SWITCHBOARD OPTION All Thermal Dispersion series switches can be configured, with an additional board, to function as a window comparator. The switch can detect between two different flow rates, two different temperatures, flow rate and temperature, or can monitor for a combination of temperature and level. FLANGE MOUNTING This option is available on the TX and TQ Series in many different sizes, ratings and face configurations. The sensor insertion length is custom specified by the user. HIGH FLOW OPTION By placing a shroud over the sensor head, the desired set-point of the instrument is extended to higher flow rates. This option is recommended in clean liquids and gases. Process Capabilities: Full Vacuum to 10,000 PSIG (690bar) -320 to 900°F / -195 to 482°C Any Dielectric Any Specific Gravity | | |
| | | The TX, TQ, and TS Switches are Field Selectable for: Gas Flow Liquid Flow Temperature Liquid Level - Adjustable for: Total Level Interface Level Foam Level Liquid Solid Interface Solids Level Available Materials: 316 / 316L SS Alloy 20 Hastelloy C-276 Titanium Mechanical or electro-polished 316 SS for sanitary & high purity service Other materials: - Consult factory Industries: Petrochemical Oil and Gas Power Utilities Pharmaceutical Food and Beverage Ships / Marine Biotechnology | | |
| | | K-TEK Thermal Dispersion Switches for Flow / Level / Temperature Applications | | |
| | | Typical Flow Applications for Thermal Dispersion Switches | | |
| | | |
| | | |
| | | Pump Protection Automatic shut-off on low/no flow Bearing Lubrication Detects loss of lubricant flow Seal Leakage Verifies positive seal flow or detects excessive leakage indicating maintenance required Energy Management Pump shut-off on loss of product to conserve energy Chemical Feed Indicates low/no flow of chemical additives to process Metering Pumps Senses loss of product flow avoiding incorrect measurement | | |
| | | tx series -STANDARD flow I level I TEMPERATURE switch One Switch for Gas or Liquid Flow, Liquid Level, Interface Level, Temperature, or Granular Solids No moving parts Type 316L Stainless Steel, welded (std) Explosion-proof Exotic alloys for corrosive applications Temperature Range -320°F to +900°F / -195°C to 482°C Pressures to 10,000 PSIG / 690bar Our standard flow/level/temperature switches are the most durable instruments available. They are ideally suited for detecting the increase or decrease in flow or level of virtually all liquids, gases, slurries and granular solids. The "no moving parts" principle of operation offers extremely reliable and repeatable operation with no vanes or linkage to stick, and no paddles to break off. This series of flow switches offers simple, reliable, and cost effective operation in the most severe industrial applications. A wide selection of threaded and flanged process connections is available and probe length can be made to customer specified length. Numerous circuit board options are available. | | |
| | | ts series - SANITARY FLOW / LEVEL / TEMPERATURE SWITCH One Switch for Gas or Liquid Flow, Liquid Level, Interface Level, Temperature, or Granular Solids Designed to 3A requirements Type 316L Stainless Steel, welded (std) Temperature Range -50°F to +350°F / -45°C to 117°C Pressures to 500 PSIG / 34.5bar Simple, reliable, cost effective The TS Series flow/level/temperature switch is designed to provide reliable detection in the food and pharmaceutical industries. These highly polished instruments, featuring quick disconnect fittings, can be used to detect the increases or decreases of flow, level or temperature in virtually all liquids, gases, slurries and granular solids. | | |
| | | |
| | | ix series IN-LINE FLOW / TEMPERATURE SWITCH | | im series LOW-COST IN LINE FLOW / TEMPERATURE SWITCH | | |
| | | |
| | | |
| | | Control Rooms Verifies flow when pumps or valves are energized Purge Air Detects loss of flow for process or Plant safety Safety Shower Indicates Safety Shower use and potential danger to Plant personnel Analyzer/Gas Chromatograph Proves continuous sample flow to instruments Spray Nozzles Detects nozzle blockage in paint or paper coating equipment Relief Valve/Rupture Disc Alarms on flow or leakage of valve or rupture discs | | |
| | | |
| | | tq series -FAST RESPONSE flow I level I TEMPERATURE switch One Switch for Gas or Liquid Flow, Liquid Level, Interface Level, Temperature, or Granular Solids No moving parts Response time from 1 second Type 316L Stainless Steel Temperature Range -50°F to +350°F / -45°C to 117°C Pressures to 2000 PSIG / 138bar Explosion-proof | | |
| | | |
| | | CONVERSION TABLE | | |
| | | These fast response flow/level/temperature switches are used when the response time in detecting the increase or decrease of flow or level is critical. With no moving parts exposed to the process they will provide extremely reliable and repeatable operation in virtually all liquids, gases, slurries, and granular solids. The QX Series has a wide selection of threaded and flanged process connections with customer selectable probe length. The varied electronic circuit board options offer the user a wide selection of power inputs and relay outputs. | | |
| | | Volumetric (G.P.M. Or C.F.M.) to Velocity (F.P.S.) | | |
| | | Response time from 1 second 316L Stainless Steel, (std), wetted parts Explosion proof enclosure optional Pressures to 4,000 PSIG / 276bar Temperature Range -50°F to +350°F / -45°C to 117°C) | | |
| | | |
| | | |
| | | LINE SIZE | | 1/0" | | 1/4" | | 3/0" | | 1/2" | | 3/4" | | 1" | | 1-1/4" | | 1-1/2" | | |
| | | |
| | | Liquid Multiplia | | |
| | | 3.08 | | 1.68 | | 1.06 | | 0.37' | | 0.215 | | 0.158 | | |
| | | 5.65 | | | 0.602 | | |
| | | |
| | | |
| | | 23.06 | | |
| | | 42.19 | | | 12.57 | | 1.61 | | 1.18 | | |
| | | 7.909 | | 4.5 | | 2.776 | | |
| | | Gas Multiplier | | |
| | | | |
| | | |
| | | Response time from 1 second 316L Stainless Steel, (std), wetted parts Explosion proof Pressures to 10,000 PSIG / 690bar Temperature Range 50°F to +350°F / -46°C to 177°C The IX Series is ideally suited for applications such as chemical injection, cooling lines, sampling lines, lubrication and other smaller flow rate situations. | | |
| | | | |
| | | LINE SIZE | | 2" | | 2-1/2" | | 3" | | 3-1/2" | | 4" | | 5" | | 6" | | 0" | | |
| | | |
| | | Liquid Multiplier Gas Multiplier | | |
| | | 0.0434 | | 0.0325 | | 0.016 | | 0.0111 | | |
| | | 0.0252 | | | 0.006 | | |
| | | 0.0956 | | 0.067 | | |
| | | |
| | | |
| | | | | | | | | | | | | CONVERSION CHART | TO cc / sec or ml / sec | | | | From: | Multiply by: | | From: | Multiply by: | | | | Gal. / Min. | 63.1 | | L/ Hr. | .278 | | | | Gal. / Hr. | 1.05 | | L/ Day | 0.0116 | | | | | | | | Gal. / Day | 0.0438 | | Ft3 / Min. | 472.0 | | | | L/ Min. | 16.7 | | M3/ Hr. | 278.0 | | | | | | | | | | | | | | | | |
| | | 0.7161 | | 0.519 | | |
| | | 0.3248 | | 0.2427 | | 0.1884 | | 0.12 | | 0.083 | | 0.048 | | |
| | | |
| | | |
| | | 10" | | 12" | | 14" | | 16" | | 10" | | 20" | | 24" | | |
| | | LINE SIZE | | |
| | | |
| | | |
| | | Liquid Multiplier | | |
| | | 0.00237 | | 0.001815 | | 0.001434 | | 0.001154 | | |
| | | 0.00407 | | 0.00287 | | | 0.000798 | | |
| | | |
| | | |
| | | 0.0304 | | 0.0177 | | 0.0136 | | 0.0107 | | 0.00863 | | |
| | | 0.0209 | | | 0.00597 | | |
| | | Gas Multiplier | | |
| | | |
| | | |
| | | EXAMPLES: Example 1: 100 CFM in 4" line = 100 x .1004 = 10.04 F.P.S. Example 2: 10 G.P.M. in 3" line = 10 x .0434 = .434 F.P.S. | | |
| | | |
| | | |
| | | |
| | | Test Conditions: 60°F, 14.7PSIA, SCH. 40 LINE | | |
| | | |
| | | |
| | | INSTRUMENT RANGEABILITY: IX & IM SERIES | | |
| | | PED CERTIFIED | | |
| | | ISO 9001 REGISTERED FIRM | | |
| | | |
| | | |
| | | |
| | | WATER | | |
| | | |
| | | 0539 0036 ATEX Certified | | |
| | | OIL | | |
| | | |
| | | |
| | | AIR | | |
| | | | Chiller Protection Automatically turns off chiller at no flow to prevent compressor failure due to slugging Heater Burn-out Prevention Heater shut-down on loss of flow to prevent overheating elements Tank Car Loading Senses dry line or phase change from liquid to nitrogen gas flow | | Drain Line Sensor Capable of detecting flow in partially filled lines Energy Management Turns off pumps, heaters, chillers, heat exchanger on loss of flow Agitation Monitor Positive indication of agitation in vessels | | |
| | | Factory Mutual System | | |
| | | ASME | | |
| | | |
| | | |
| | | 1.0 | | 10 | | 100 | | 1,000 | | 10,000 | | |
| | | |
| | | |
| | | (g | | |
| | | Range Tube #1 IX / 1875 | | Range Tube #2 IX / 2575 | | IX / 7575 | | IM / 2525 | | |
| | | |
| | | |
| | | |
| | | |
| | | Flow Rate cc / sec or ml / sec | | |
| | | |
| | | CSA | | |
| | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |