Text version of the page
Text version of the page
| | | | | | | | | | | | | Technical data | | | | | | | | | | | | | | | | | | | | | | Designation | JUMO dTRANS T02 j | JUMO dTRANS T02 PCP | JUMO dTRANS T02 LCD | JUMO dTRANS T02 Ex | | | | | | Type | 707020 | 707021 | 707022 | 707025 | | | | | | Special features | | as 707020, | as 707021, | Ex version | | | | | | | between measurement | in addition: | in addition: | Ce™©ll(l)GD[EEx ia]IIC | | | | | | | input, output and | 2 open collectors, | on-site actual value | | | | | | | | auxiliary voltage, | signal output can also | indication, can be | | | | | | | | compact design | be measured via test | configured without | | | | | | | | | sockets | setup | | | | | | | Housing width | 17.5 mm | 22.5mm | 22.5mm | 22.5mm | | | | | | Display | none | 2 LEDs | 2 LEDs, 1 LC display | 2 LEDs | | | | | | Keys | none | 2 keys | 3 keys | 2 keys | | | | | | Supply | 24V DC + 10%/15% | 20 - 53V AC/DC | 20 - 53V AC/DC | 20 - 53V AC/DC | | | | | | | | 110 - 240V AC | 110 - 240V AC | 230 V AC ±10% | | | | | | Inputs | | thermocouple, | thermocouple, | thermocouple, | | | | | | | Pt100, | Pt100, Pt500, Pt1000 | Pt100, Pt500, Pt1000 | Pt100, Pt500, Pt1000 | | | | | | | Pt500 (restricted) | resistance transmitter, | resistance transmitter, | resistance transmitter, | | | | | | | Pt 1000 (restricted), | | potentiometer, | potentiometer, | | | | | | | current with external | current (up to ± 20 mA), | current (up to ± 20 mA), | current (up to ± 20mA), | | | | | | | shunt, voltage | voltage (up to ± 10 V) | voltage (up to ± 10 V) | voltage (up to ± 10V) | | | | | | | (mV range) | | | | | | | | | Outputs | 0 - 20mA, 4 - 20mA, | 0 - 20mA, 4 - 20mA, | 0 - 20mA, 4 - 20mA, | 0 - 20mA, 4 - 20mA, | | | | | | (can be reversed) | 0 - 10V | 0 - 10 V, | 0 - 10 V, | 0 - 10V | | | | | | | | 2 open collectors | 2 open collectors | | | | | | | Transfer | linear with temperature, | linear with temperature, | linear with temperature, | linear with temperature, | | | | | | characteristic | customized linearization | customized linearization | customized linearization | customized linearization | | | | | | Digital outputs | - | 2 limit comparators or | 2 limit comparators or | - | | | | | | | | 1 limit comparator | 1 limit comparator | | | | | | | | | and 1 frequency output | and 1 frequency output | | | | | | | Operation | can be configured | fine calibration and | entirely configurable | fine calibration from | | | | | | | entirely through | limits from instrument | on site from the | instrument keys, | | | | | | | setup program | keys, instrument | 3 instrument keys, | instrument configuration | | | | | | | | configuration through | or through the setup | through setup program | | | | | | | | setup program | program | | | | | | | | | | | | | | | | | | | | | | | | | | | Further | | | | | | | | | | information | Data Sheet 70.7020 | Data Sheet 70.7020 | Data Sheet 70.7020 | Data Sheet 70.7020 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|