six or twelve universal measurement inputs, electrically isolated, test voltage 500V, minimum
industrial sampling rate 125msec for twelve measurement inputs expansion to 36 measurement channels (mTRON, PROFIBUS-DP, MODBus) Ethernet interface 10 Base T (option) data recording in compliance with FDA 21 CFR Part 11 data storage in internal memory and/or on CompactFlash >
® card (64 to 256 Mbyte) batch reports electronic signature Audit Trail Manager for the evaluation of all operator actions Security Manager for the creation of user lists data transfer via PC Communications software configurable via modem or Ethernet interface bezel size 144mm x 200mm, depth behind panel 200mm stainless steel front (on request) designed for use with enhanced safety requirements special
access control via user list further information: Data Sheet 70.6560 six or twelve universal measurement inputs, electrically isolated, test voltage 500V, minimum sampling rate 125msec for twelve measurement inputs expansion to 36 measurement channels (mTRON, PROFIBUS-DP, MODBus) Ethernet interface 10 Base T (option) data storage in internal memory and/or onCompactFlash >
® card (64 to 256Mbyte) life cycle archiving concept batch reports online connection to the SVS-2000N Process
Visualization software configurable via modem or Ethernet interface bezel size 144mm x 200mm, depth behind panel 200mm further information: Data Sheet 70.6570 >