See other catalogues for JUMO
You may also be interested in
Text version of the page
| | | | | | | | | | | | | | | 7 8 S LI N | | | | | | | | | | | | | | | | | | | | | | | | Type | (S)TBOw(t)-54 | 701140/... (TB / TW) | | | | Dimensions (L x W x H) | 54mmx70mmx110mm | 22.5 mmx109mmx124.8 mm | | | | Connections | screw connections | screw terminals | | | | Enclosure protection | IP20 (EN 60529) | IP20 | | | | Function | safety temperature monitor, safety temperature limiter | temperature limiter, temperature monitor | | | | Measurement inputs | Pt100 resistance thermometer, thermocouples type K, S, B, L | freely configurable for resistance thermometer, thermocouple, current and voltage signals | | | | Setpoint adjustment | analog rotary knob with lead-sealable cap | - | | | | Output | relay with changeover contact 2A/230V | relay output (changeover contact) logic output (voltage/current 4.5V/20mA) | | | | Supply | 24 V AC +10/-15%, 48 - 63 Hz 115V AC +10/-15%, 48 - 63Hz 230 V AC +10/-15 %, 48 - 63 Hz | 20 - 53 V AC/DC, 48 - 63 Hz 110 - 240V AC +10/-15%, 48 - 63Hz | | | | Features/extra functions | internal or external reset button, minimum/maximum function, DIN rail mounting, lead-sealable cover | freely configurable through setup program or keys, only one instrument for TB and TW, alphanumerical LC display, 17 linearization options, pre-alarm can be set as absolute or relative to limit value, differential measurement and monitoring | | | | Approvals | DIN 3440, GL, GL, (S)TB/(S)TW with thermocouples as per IEC 61 508, SIL 3, (S)TB /(S)TW or TB /TW with resistance elements as per IEC 61 508, SIL 2 | DIN 3440, UL | | | | Additional information | Data Sheet 70.1130 | Data Sheet 70.1140 | | | | | | | | | | | | | | | | | | | | | | |
|