AKKUTEC 2410-0 - 2 Pages

  1. P. 1

  2. P. 2

Catalogue excerpts

Battery- buffered power supply in Parallel operation (On-Line) without battery for ext. battery manufacturer: J. Schneider type : AKKUTEC 2410-0 Art.-No. : NBPAN33G1M01 1. Short description The battery buffered DC power supply of the series AKKUTEC is working according the stand-by parallel mode and ensures in connection with a lead-acid accumulator a safe continuous DC power supply in case of mains failure. The power supply has the following features: • • • • • Primary switched power supply with I/U-charging characteristics active power factor correction (PFC) Battery management by micro-controller Battery voltage tracking of the charging voltage by external sensor module (optional) Display- and control panel for mount in cabinet door or module (optional) Nominal input voltage Nominal frequency Nominal output voltage Depending of state of charge of the battery Nominal output current Protective system Secure separation (safe separation between input and output ) Operational temperature Short circuit protection battery Battery fuse Back-up time Charging characteristics Final charging voltage Charging current at 100% load Charging current at 0% load Deep discharge protection of the battery LED-display Control inputs referring to earth on +24VDC 230 V AC -15% +10% 50/60 Hz 24 V DC ± 0,5% 19,8...26,4 V DC 10 A bei 100% ED IP 20 According to EN61558-2-17 0 - 40 ° C optimal storage temperature for battery 20° Durin g C. storage charge battery each 6 month. electronic, short-circuit-proof output external external Depending on battery I/U DIN 41773 part 1 Opt. Battery voltage tracking Boost-charge via controla contact ( til 28,6V ) 26,4 V DC 1,5 A 11,5 A load rejection at a battery voltage ≤ 19,8 V mains / battery operation 'Netz OK' green LED illuminates general error 'Fehler' yellow LED illuminates battery voltage within green LED illuminates battery voltage above green LED illuminates mains/UPS-operation 0,5 A /30 V DC general error 0,5 A /30 V DC battery voltage above 0,5 A /30 V DC battery voltage within 0,5 A /30 V DC Shut-down

 Open the catalogue to page 1

Special features expendable active PFC Battery management Battery circuit control Real battery power control Type of construction connection dimensions boost charge Active current division at Master – Slave respectively redundant operation via CS-Bus Time function (load rejection after adjustable back-up time) In 10A steps Master/Slave Harmonic ripple at input according to EN 61000-3-2 PF ∼ 0,99 Battery management via internal Microcontroller, control battery circuit / battery fuse each 60sec Battery load test during mains operation (load of the battery with simultaneous voltage measurement )...

 Open the catalogue to page 2

All J. Schneider Elektrotechnik catalogues and technical brochures

  1. SPS Advance RT

    2 Pages

    En
  2. MLT C 10 - 20

    10 Pages

    En
  3. UCC - TEC 450

    2 Pages

    En
  4. NCBG1115G01002

    4 Pages

    En
  5. NCBG1138G01001

    2 Pages

    En
  6. AKKUTEC 2403C

    5 Pages

    En
  7. AKKUTEC 2412C

    4 Pages

    En
  8. C-TEC 1203-1

    1 Pages

    En
  9. UNOTEC 2420

    2 Pages

    En
  10. UNOTEC 2405N

    2 Pages

    En
  11. CEM12V12

    1 Pages

    En
  12. CEM1

    1 Pages

    En
  13. AC-C-TEC 2403-05

    1 Pages

    En
  14. C-TEC 2408-20

    1 Pages

    En
  15. AKKUTEC 2403

    2 Pages

    En
  16. AKKUTEC 2403 DC

    2 Pages

    En
  17. C-TEC 2403-05

    1 Pages

    En
  18. AKKUTEC 2405

    2 Pages

    En

Archived catalogues

  1. DC-UPS systems

    16 Pages

    En
  2. Focus on

    16 Pages

    En