AKKUTEC 2405 - 2 Pages

  1. P. 1

  2. P. 2

Catalogue excerpts

Battery- buffered power supply manufacturer: J. Schneider Elektrotechnik GmbH type : AkkuTEC 1205 USB Art.-No. : NBPA0616G01004 Short description The battery buffered DC power supply of the series AKKUTEC is working according the stand-by parallel mode and ensures in connection with a lead-acid accumulator a safe continuous DC power supply in case of mains failure. The back-up time depends on the state of charge of the accumulator and of the discharge current. The power supply has the following features: • • • • Battery charger with I/U-charging characteristics Battery management by micro-controller Battery voltage tracking of the charging voltage by external sensor module (optional) USB interface: with corresponding drivers and Schneider TECControl Software message contracts can be controlled and a Shut-Down/Restart can be made. Nominal input voltage Nominal frequency Nominal output voltage at mains operation Depending of state of charge of the battery Nominal output current Protective system Secure separation (safe separation between input and output) Operational temperature Short-circuit protection Battery Battery type Battery fuse Back-up time Charging characteristics Charging current at 100% load Charging current at 0% load Deep discharge protection of the battery 115 - 230 V AC -15% +10% 47 – 63, Hz 12,4 V DC ± 0,4% (without Temp.-Sensor) 13,5 V DC ± 0,4% (with Sensor at 25° C) 9,9...13,2 V DC 5 A bei 100% ED current limiting at 1,1 x I Nenn IP 20 According to EN61558-2-17 (VDE 0570 2-17) 0 - 40 ° C optimal storage temperature for battery 20° Durin g C. storage charge battery each 6 month. Electronic, short-circuit-proof output External Pb-Akku, maintenance free Pb- Akku maintenance free (Option with modified characteristic curve) External Depending on battery I/U DIN 41773 part 1 Opt. Battery voltage tracking 0.5 A 5.5 A Load rejection at a battery voltage ≤ 9,9 V

 Open the catalogue to page 1

Shut down terminal (emergency stop) Battery management Battery circuit control Real battery power control EMC-regulation Type of construction connection dimensions Ua green voltage is present at the output Netz OK green input voltage is present Batterie OK green expires at: -battery circuit interruption (battery fuse damaged) -voltage in UPS operation < 21,6 V (battery low) -battery temperature above 45° C LED is blinking at -battery low (damaged battery) mains/UPS-operation 0,5 A /30 V DC general error 0,5 A /30 V DC for parameterisation for operation with optional TECControl software as shut...

 Open the catalogue to page 2

All J. Schneider Elektrotechnik catalogues and technical brochures

  1. SPS Advance RT

    2 Pages

    En
  2. MLT C 10 - 20

    10 Pages

    En
  3. UCC - TEC 450

    2 Pages

    En
  4. NCBG1115G01002

    4 Pages

    En
  5. NCBG1138G01001

    2 Pages

    En
  6. AKKUTEC 2403C

    5 Pages

    En
  7. AKKUTEC 2412C

    4 Pages

    En
  8. C-TEC 1203-1

    1 Pages

    En
  9. UNOTEC 2420

    2 Pages

    En
  10. UNOTEC 2405N

    2 Pages

    En
  11. CEM12V12

    1 Pages

    En
  12. CEM1

    1 Pages

    En
  13. AC-C-TEC 2403-05

    1 Pages

    En
  14. C-TEC 2408-20

    1 Pages

    En
  15. AKKUTEC 2410-0

    2 Pages

    En
  16. AKKUTEC 2403

    2 Pages

    En
  17. AKKUTEC 2403 DC

    2 Pages

    En
  18. C-TEC 2403-05

    1 Pages

    En

Archived catalogues

  1. DC-UPS systems

    16 Pages

    En
  2. Focus on

    16 Pages

    En