AKKUTEC 2403 - 2 Pages

Add to MyDirectIndustry favorites
AKKUTEC 2403

Catalog excerpts

J. Schneider Elektrotechnik UPS - System Battery-buffered power supply manufacturer: J. Schneider Elektrotechnik GmbH type    : AKKU TEC 2403 Short description The battery buffered DC power supply of the series AKKU TEC is working according the stand-by parallel mode and ensures in connection with a lead-acid accumulator a safe continuous DC power supply in case of mains failure. The back-up time is depending from the state of charge of the accumulator and of the discharge current. The power supply has the following features: • Battery charger with I/U-charging characteristics • Battery management by micro-controller • Battery voltage tracking of the charging voltage by external sensor module (optional) Nominal input voltage Nominal frequency System voltage Output voltage (depending of state of charge of the battery) - with temperature sensor    19,8V DC-27,8V DC - without temperature sensor    19,8V DC-26,8V DC Nominal output current Protective system Secure separation (safe separation between input and output) Operational temperature Short circuit protection Battery Type of battery Battery fuse Back-up time Charging characteristics Charge voltage without temperature sensor with temperature sensor at 25° 2,85 A at 100% ED current limiting at 1,1 x I Nenn IP 20 According to EN61558-2-17 (VDE 0570 2-17) 0 - 40 °C optimal storage temperature for battery 20°C. During storage charge battery each 6 month. electronic, short-circuit-proof output External Pb-Akku, maintenance free Pb- Akku maintenance free (Option with modified characteristic curve) External Depending on battery I/U DIN 41773 Teil 1 Opt. Battery voltage tracking 26,8 V DC ± 0,4% 27,1V DC ± 0,4% Adresse: Helmholtzstrasse 13 D-77652 Offenburg Postfach 2327 D-77656 Offenburg Geschaftsfuhrer: Bettina Schneider Dipl.Betriebswirt (BA) Rolf Anti Dipl.-Wirt.-Ing.(FH) Amtsgericht Offenburg HRB 758

 Open the catalog to page 1

Charging current at 100% load    0.25 A Charging current at 0% load    2,85 A Deep discharge protection of the battery    Load rejection at a battery voltage < 19,8 V Relais-outputs Control input referring to earth 24 V Shut down terminal (emergency stop) Battery management Battery circuit control Real battery power control Type of construction Connection Dimensions Weight Options Shut down Software Battery voltage tracking Net OK green input voltage is present Battery OK green expires at: -battery circuit interruption (battery fuse damaged) -voltage in UPS operation < 21,6 V (Battery...

 Open the catalog to page 2

All J. Schneider Elektrotechnik catalogs and technical brochures

  1. CEM 24-8

    2 Pages

  2. CEM 24-2

    2 Pages

  3. UCC-TEC

    2 Pages

  4. UCC-TEC 450

    2 Pages

  5. CEM 24-1

    2 Pages

  6. AKKUTEC 2403 DC

    3 Pages

  7. AKKUTEC 2405

    2 Pages

  8. AKKUTEC 2403 DC

    3 Pages

  9. UPSO 2420

    2 Pages

  10. DC-UPS

    3 Pages

  11. MLM 10 - 20

    11 Pages

  12. AKKUTEC SVC

    2 Pages

  13. SPS Advance RT

    2 Pages

  14. MLT C 10 - 20

    10 Pages

  15. UCC - TEC 450

    2 Pages

  16. NCBG1115G01002

    4 Pages

  17. NCBG1138G01001

    2 Pages

  18. AKKUTEC 2403C

    5 Pages

  19. AKKUTEC 2412C

    4 Pages

  20. C-TEC 1203-1

    1 Pages

  21. UNOTEC 2420

    2 Pages

  22. UNOTEC 2405N

    2 Pages

  23. CEM12V12

    1 Pages

  24. CEM1

    1 Pages

  25. C-TEC 2408-20

    1 Pages

  26. AKKUTEC 2410-0

    2 Pages

  27. AKKUTEC 2403

    2 Pages

  28. AKKUTEC 2403 DC

    2 Pages

  29. C-TEC 2403-05

    1 Pages

  30. AKKUTEC 2405

    2 Pages

Archived catalogs

  1. DC-UPS systems

    16 Pages

  2. Focus on

    16 Pages