EWN-Y-A & EFS
2Pages

{{requestButtons}}

Catalog excerpts

EWN-Y-A & EFS - 1

IWAKI ANTI-GAS LOCK PUMP UNIT The Auto-air vent valve eliminates the gas-lock problem with continuance bleeding liquid and gas constructions. A precise flow measuring per stroke and a feed back control enable precise chemical dosing, mean while the bleeding system is normally difficult to keep precise dosing. The system can also bleed gas out as short time as possible, even if setting discharge flow is small. Philosophy of the Non-Gas Lock system Flow Measured flow 10 mL/min Measured flow 0 mL/min Measured flow 0 mL/min 10 mL/min Set = operating pump speed 10 mL/min Gas with liquid The bleeding system takes gas and liquid out from the pump chamber. However, dosing capacity is kept setting volume due to feed back control with the flow signal. Set = operating pump speed 10 mL/min Set = operating pump speed Max. speed When large volume of gas comes into the pump chamber, pump discharge capacity will be "zero" until bleeding the gas out. The feed back control increase pump operating speed, thus gas bleeding time will be in short time. When the gas bleeding is completed, the pump discharge volume returns to the setting valve immediately by the feed back control with the flow signal.

Open the catalog to page 1
EWN-Y-A & EFS - 2

IWAKI ELECTROMAGNETIC METERING PUMPS Wet-end materials VC 1 Pump head 2 Valve 3 Valve seat 4 Diaphragm 5 Gasket 6 O ring 7 EFS body 8 EFS electrode 9 Separate pin PVC Alumina ceramic HastelloyC276 FKM EPDM PTFE+EPDM PTFE FKM EPDM PVDF Hastelloy C22 Titanium or equivalent Titanium Hasteroy C276 Auto control 6 O ring 2 Valve 9 Separate pin Operational mode EXT control 1 Pump head 4 Diaphragm 5 Gasket 3 Valve seat Specifications of pump Model Capacity Discharge capacity per shot Rated discharge pressure Stroke length adjustable range Stroke rate Standard connection (Hose dia) Current Average...

Open the catalog to page 2

All IWAKI Europe GmbH catalogs and technical brochures

  1. TC-X

    28 Pages

  2. IX-B

    8 Pages

  3. MEK

    5 Pages

  4. MMP

    2 Pages

  5. MP series

    2 Pages

  6. MTFO

    2 Pages

  7. IX-C/D

    12 Pages

  8. NRD/RD

    4 Pages

  9. SMX-F

    8 Pages

  10. EJ-R

    2 Pages

  11. EWN-W

    2 Pages

  12. V

    8 Pages

  13. Serie MDW

    8 Pages

  14. MDE

    8 Pages

  15. MDM

    5 Pages

  16. MXM

    5 Pages

  17. SMX

    8 Pages

  18. RD-40

    2 Pages

  19. EWN-Y

    8 Pages

  20. EWN-A

    2 Pages

  21. MX

    8 Pages

  22. MD-F, MD-V

    10 Pages

  23. HRP

    2 Pages

  24. MDM NP

    8 Pages

  25. FW/-H

    12 Pages

  26. Serie YMD

    8 Pages

  27. Serie CFD

    12 Pages

  28. Serie FA

    12 Pages

  29. Air pumps

    8 Pages

  30. Serie MDT

    2 Pages

Archived catalogs

  1. RD

    4 Pages

  2. Hicera pumps

    4 Pages