You may also be interested in
Magnetic pump, Dosing unit, Damper, Pump, Bellow pump
Text version of the page
Standard Product Capabilities
Pump solutions from a World Leader
FF Series
Low to medium temperature bellows pump
Iwaki America’s FF Series pumps are economical solutions for
low to medium temperature liquid applications (5 to 100°C).
PTFE bellows and liquid end share the same proven design and
manufacturing quality as the rest of the F Series family,
ensuring high purity and long service life. All metal parts
are fully encapsulated.
The FF-10/20CT2 has a PVC housing coated with fluoroplastic,
suitable for liquids up to 50°C; a fluoroplastic encapsulated
housing allows the FF-10/20BT2 to pump fluids up to
100°C.
Integral PFA tube connections mean there are no crevices
or seams where particles can accumulate. A wide variety
of fittings can be easily attached.
Intelligent sensor technology is a standard FF series feature:
pressure, stroke and speed are optimized, maintaining accurate
chemical delivery and extending pump life. Leak detection
ensures immediate response to hazards.
2 SIZES to 22 LPM , LOW and MEDIUM
TEMPERATURE RATED
Specifications
AIR CHAMBER “B”
SUCTION VALVE
ASSEMBLY
LIQUID CHAMBER “B”
LEAK DETECTOR “B”
LEAK DETECTOR “A”
BELLOWS “A” BELLOWS “B”
CONNECTING ROD
SHAFT SYSTEM
PROXIMITY
SENSOR
“B”
AIR SUPPLY
PORT “B”
AIR SUPPLY
PORT “A”
PROXIMITY
SENSOR
“A”
AIR CHAMBER “A”
LIQUID CHAMBER “A”
DISCHARGE PORT (TUBING)
DISCHARGE
VALVE ASSEMBLY
Model FF-10BT2 FF-10CT2 FF-20BT2 FF-20CT2
Maximum discharge
capacity1 2.6 gal/min (10 L/min) 5.8 gal/min (22 L/min)
Maximum stroke speed 120 spm
Maximum stroke length 0.7 in. (18 mm) 0.9 in. (24 mm)
Self-priming ability 2 3.28 ft. (1 m) 6.56 ft. (2m)
Liquid temperature range
41-212°F
(5-100°C)
41-122°F
(5-50°C)
41-212°F
(5-100°C)
41-122°F
(5-50°C)
Maximum air supply
pressure 43 PSi (3 kg/cm2)
Liquid contacting material PFA/PTFE
Pump connection size PFA ½” tubing PFA ¾” tubing
Supply air connection size* ¼” PT
Maximum air consumption 90 NL/min (3.2 CFM) 180 NL/min (6.4 CFM)
Ambient temperature 32-104°F (0-40°C)
* NPT conversion fittings are available.
1 The maximum discharge volume is based on pure water at room temperature.
2 The self-priming value is based on the maximum stroke rate with pure water at
room temperature.
|
|