| | Peel Test - 3mil PET to Steel. Fusion Systems 300WPI lamp -"D" (doped) bulb @ 4 inches. | |
| | | |
| | | | | | | | | | | | | | | Nominal Thickness -mil inch - pli | | 30 second peel - pound per linear | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | |
| | NOTE: All of these test pieces passed >10 days of creep resistance at ambient and 50C. Peel Force to Various Substrates. PSTM1 Test., 3-mil adhesive on PET film, Cured at 1.2 J/cm2 with Fusion System D bulb. Assembled and then tested at 24 hours. 90° peel test | |
| | | |
| | | |
| | | |
| | Static Shear or "Creep Resistance" Test. To determine the resistance of the adhesive to "creep", the same assembly as for the peel test is prepared except that a one-inch overlap of the Mylar to steel is made. After a 24 hour bond time, a one kilogram weight is hung from the Mylar film and the number of hours recorded to failure. Greater than 10 days is considered a "passing" value. DEVCON UV PSA products undergo a dramatic improvement in static shear with ambient aging after UV cure. This aging occurs if the adhesive has been used to assembly parts or laminates as well as a film under a release liner. Static Shear - PET to Steel, 3-mil adhesive, 1.0J/cm2 doped bulb, 1 sq. in. overlap, 24 hr. bond time, 1 kilogram static load. | |
| | | |
| | | | | | | | | | Time to Failure - minutes | | | | | | | | | | >14,400 min. (test halted @ 10 days | | | | | | | | |
| | | |
| | Order No. Size 18401 25ml syringe | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |