Flanged Electric Vibrators MVB - Italvibras - #1

/ 2


catalogue search
Flanged Electric Vibrators MVB - Italvibras
P. 01
Flanged Electric Vibrators MVB - Italvibras
P. 02
Pages:
Flanged Electric Vibrators MVB - Italvibras


See other catalogues for Italvibras
You may also be interested in

Vibrator, Electric vibrator


Text version of the page
muB-
The MVB-E and MVB-E-FLC flanged vi­brator series have been designed for use in industrial processes with screens and sieves in environments with a potentially explosive atmosphere, caused by gas and dusts, in compliance with ATEX Directive (94/9/CE).
These vibrators can be supplied in B, C, D versions (see page 86) according to the ec­centric weights supplied with the vibrator and to be mounted by the user.
In particular, these vibrators can be used in areas 1 and 2 (gas) and in areas 21 and 22 (dusts) according to the layout and the following features:
Category: II 2 G,D
Level of protection: Ex e II, tD A21 IP66
Temperature class:
Gas: T3 (200°C) or T4 (135°C) Dusts: 150°C
EC certificate: LCI E 06 ATEX Areas of use: 1, 2, 21, 22
Technical features
Certifications
Power supply
Three-phase voltage from 220V to 690V, 50Hz or 60Hz; suitable for use with an inverter from 20Hztothe base frequency with constant torque load profile.
Polarity
4 poles.
Conformity with European Directives
ATEX 94/9/CE; Electromagnetic Compatibility
89/336/CE
Reference Regulations
I EC/EN 60079-0, IEC/EN 60079-7, IEC/EN 61241-0, IEC/EN 61241-1, EN 60034-1, EN 50081-1, EN 50081-2, EN 50082-1, EN 50082-2.
Controls
The components that affect protection are 100% accurately controlled and recorded. The vibrators undergo 100% dynamic tests on the bench.
Functioning
Continual service (SI) at maximum declared centrifugal force and electric power.
Centrifugal force
1500 Kgf. (14.7 KN), adjustable with variation of the eccentric weights.
Mechanical protection
IP 66 according to IEC 529, EN 60529.
Shock-proof protection
IK08 according to IEC 68, EN 50102.
Insulation class
ClassF(155°C).
Tropicalization
Standard with "drop by drop" trickle system.
Environmental temperature
From -10°C to +40°C, on request it is possible to have vibrators for max. environmental tem­peratures 55°C. On request special greases for temperatures less than -10°C.
Vibrator heat protection
Standard PTC rated thermistor heat detectors 130°C (DIN 44081 -44082) from size 80, on request for smaller sizes. Also on request thermistors with different temperatures and anti-condensation heaters.
Fixing of the vibrator
In all positions and therefore without restric­tion.
Lubrication
All vibrators are lubricated in the factory and do not require further lubrication if used in normal operating conditions. In heavy duty operating conditions periodical re-lubrication may be applied.
Terminal box
Large fixed electrical connections. Special shaped terminals allow to fix the power supply cable, protecting it from loosening.
Electric motor
Three-phase asynchronous type. Insulated windings using "drop by drop" trickle system with class H resin. The rotor is die cast aluminium.
Casing
In ductile cast iron to have high strength and optimal elasticity.
An external earthing screw is located on the casing as prescribed by Regulation IEC/EN 60079-0.
Bearing flange
Constructed in ductile cast iron. The geometry of the flange transmits the load to the casing uniformly.
Bearings
Custom made with particulargeometry, especially designed for Italvibras, suitable to support both high radial and axial loads.
Motor shaft
In treated steel alloy (Isothermic hardening) resistant to stress.
Eccentric weights
Lamellar for clamped centric weigh have an ample possibility of adjustment: the particular adjustment system adopted allows to obtain phase shift from 0 to 180° of the group of upper weights with respect to the group of lower weights and to have ample adjustment of the centrifugal force within the same group of weights.
Weight covers
Not envisioned in the MVB-E and MVB-E-FLC
II 2 G, D - Class Ex e II T4/T3 tD A21 IP 66. IEC/EN 60079-0, IEC/EN 60079-7, IEC/EN 61241-0, IEC/EN 61241-1. Certificate n° LCIE 06 ATEX
<£>„ICiE
GGTN Permit and Gost-R certificate for increased safety Ex e: GOST R 51330.0-99, GOST R 51330.8-99, GOSTR IEC 61241-1-1-99.
Comply with the applicable European Union directives
Painting
Electrostatic surface treatment based on poly­merised epoxy polyester powder in oven at 200°C. Tested in salt spray for 500 hours.
Other features
The MVB-E and MVB-E-FLC series are equipped with special cable-holders in compliance with ATEX Ex e II Regulations and are characterised by two plates.
italvibras g.siungarai
84
85

pageCatalog pdf di En 2012-05-22-30