| | | The MVB-E and MVB-E-FLC flanged vibrator series have been designed for use in industrial processes with screens and sieves in environments with a potentially explosive atmosphere, caused by gas and dusts, in compliance with ATEX Directive (94/9/CE). These vibrators can be supplied in B, C, D versions (see page 86) according to the eccentric weights supplied with the vibrator and to be mounted by the user. | | In particular, these vibrators can be used in areas 1 and 2 (gas) and in areas 21 and 22 (dusts) according to the layout and the following features: Category: II 2 G,D Level of protection: Ex e II, tD A21 IP66 Temperature class: Gas: T3 (200°C) or T4 (135°C) Dusts: 150°C EC certificate: LCI E 06 ATEX Areas of use: 1, 2, 21, 22 | | |
| | | Power supply Three-phase voltage from 220V to 690V, 50Hz or 60Hz; suitable for use with an inverter from 20Hztothe base frequency with constant torque load profile. Polarity 4 poles. Conformity with European Directives ATEX 94/9/CE; Electromagnetic Compatibility 89/336/CE Reference Regulations I EC/EN 60079-0, IEC/EN 60079-7, IEC/EN 61241-0, IEC/EN 61241-1, EN 60034-1, EN 50081-1, EN 50081-2, EN 50082-1, EN 50082-2. Controls The components that affect protection are 100% accurately controlled and recorded. The vibrators undergo 100% dynamic tests on the bench. Functioning Continual service (SI) at maximum declared centrifugal force and electric power. Centrifugal force 1500 Kgf. (14.7 KN), adjustable with variation of the eccentric weights. Mechanical protection IP 66 according to IEC 529, EN 60529. | | Shock-proof protection IK08 according to IEC 68, EN 50102. Insulation class ClassF(155°C). Tropicalization Standard with "drop by drop" trickle system. Environmental temperature From -10°C to +40°C, on request it is possible to have vibrators for max. environmental temperatures 55°C. On request special greases for temperatures less than -10°C. Vibrator heat protection Standard PTC rated thermistor heat detectors 130°C (DIN 44081 -44082) from size 80, on request for smaller sizes. Also on request thermistors with different temperatures and anti-condensation heaters. In all positions and therefore without restriction. Lubrication All vibrators are lubricated in the factory and do not require further lubrication if used in normal operating conditions. In heavy duty operating conditions periodical re-lubrication may be applied. | | Terminal box Large fixed electrical connections. Special shaped terminals allow to fix the power supply cable, protecting it from loosening. Electric motor Three-phase asynchronous type. Insulated windings using "drop by drop" trickle system with class H resin. The rotor is die cast aluminium. Casing In ductile cast iron to have high strength and optimal elasticity. An external earthing screw is located on the casing as prescribed by Regulation IEC/EN 60079-0. Bearing flange Constructed in ductile cast iron. The geometry of the flange transmits the load to the casing uniformly. Bearings Custom made with particulargeometry, especially designed for Italvibras, suitable to support both high radial and axial loads. Motor shaft In treated steel alloy (Isothermic hardening) resistant to stress. | | Eccentric weights Lamellar for clamped centric weigh have an ample possibility of adjustment: the particular adjustment system adopted allows to obtain phase shift from 0 to 180° of the group of upper weights with respect to the group of lower weights and to have ample adjustment of the centrifugal force within the same group of weights. Weight covers Not envisioned in the MVB-E and MVB-E-FLC | | |