PCi is a compact benchtop photon counting spectrofïuorimeterfor research applications de­manding the highest sensitivity.
PCi optical design and automatic instrument control are state-of-the-art for steady-state fluorescence measurements.
Key Features
■ A compact footprint and short optical pathlength for maximum sensitivity and efficient light cou-plinginto thesample
■ T-format and parallel beam design for fast and precise polarization measurements
■ Full automation of instrument components including: cuvette holder, polarizers, shutters, filterwheel, monochromators and stirrers
■ PC-controlled integration oftemperature bath, titrator, stopped-flow apparatus and pressure pump
■ Fast kinetic measurements with one millisecond resolution in photon counting mode
■ 80 MHz pre-amplifier discriminators delivering linearity up to eight million counts per second on each channel
■ Upgradable for time-resolved measurements with picosecond resolution
Ready-to-Use & User-Friendly Software
PCi includes Vinci-Multidimensional Fluorescence Spectroscopy, a powerful software package that provides several ready-to-use routines for reliable, user-friendlyacquisition of complexfluorescence data:
■ Spectra (excitation, emission, synchronous, time-resolved and polarization)
■ Measurements at fixed wavelengths (intensity and polarization)
■ Measurementofkinetics
■ Time-resolved measurements (lifetimes and rotational correlation times)
Fully Automated for Steady-State Applications
■ Corrected excitation and emission spectra
■ Polarization (anisotropy) measurements
■ Slowandfastkinetics
■ Synchronous luminescence spectra
■ Intensity measurements at fixed wavelengths
■ Dual-wavelength excitation (emission) ratiometric measurements
User-Defined Acquisition Protocols
One-dimensional and multi-dimensional data acquisition with user-defined protocols. The user can select any ofthe following experimental combinations:
Excitation (Emission) Wavelength and/oranyofthefollowing:
■ Emission (Excitation) Wavelength
■ SampleConcentration.pH, Pressure and Temperature
Fluorescence Intensity Polarization/Anisotropy Ratiometric Measurements
Vinci, the Complete Software Solution for Steady-State and Time-Resolved Applications
Apowerfulandflexiblemultidimensionalfluorescence spectroscopysoftware with ready-to-use routinesfor data acquisition and analysis.
Innovations in Fluorescence

pageCatalog pdf di En 2012-05-22-30