catalogue search
|
You may also be interested in
Filter, Transducer, Data-logger, Residual current circuit breaker, Network synchronization unit
Text version of the page
19
Contactors
MAIN CIRCUIT
Type KNL9 KNL12 KNL16 KNL18 KNL22 KNL30
Rated motor power
single-phase
115 V
Pe HP
1 1 1˝ 1˝ 2 2
according to UL 230 V 2 2 3 3 3 5
three-phase
230 V 3 3 5 5 7˝ 10
460 V 5 5 7˝ 7˝ 15 20
575 V 7˝ 7˝ 10 10 15 20
Electrical endurance of contacts AC-3 / AC-4 op.c. diagram 2 / diagram 3
Rated operational current at
24/110/220 V
DC-1
1 1)
Ie A
15 / 6 / 4 28 / 7 / 4
2 1) 18 / 12 / 8 30 / 23 / 13
3 1) 20 / 15 / 10 32 / 25 / 20
1) Number of poles in series DC-3 - DC-5
1 1) 12 / 2 / 0.75 18 / 2 / 1
2 1) 15 / 8 / 1.5 23 / 13 / 2
3 1) 18 / 12 / 6 28 / 18 / 9
Max. back-up fuse for short-circuit protection gL
Coordination type 2 Iv A 25 25 35 35 50 50
Terminal capacity
rigid
S mm2 0.75 … 6 2.5 … 10
flexible 0.5 … 6 1.5 … 10
Screw M3.5 M4
Screw head PZ2 PZ2
Tightening torque Nm 1.4 1.8
AUXILIARY CIRCUIT
Rated insulation voltage Ui V 690 -
Thermal current Ith A 20 -
Rated operational current 230 V
Ie A
6 -
400 V 4 -
AC-15 500 V 2 -
690 V 1 -
Rated operational current 24 V
Ie A
10 -
60 V 4 -
DC-13 110 V 0.9 -
220 V 0.4 -
Max. back-up fuse for short-circuit protection gL
Coordination type 2 Iv A 20 -
Terminal capacity
rigid
S mm2
0.75 … 6 -
flexible 0.5 … 6 -
Screw M3.5 -
Screw head PZ2 -
Tightening torque Nm 1.4 -
MAGNETIC SYSTEM
Coil consumption
switch-on
Pc
VA 66
W 48
operation
VA 8
W 2.5
make
NO
ms
10 - 20 10 - 20
NC 15 - 25 -
Make / Break delay
break
NO 10 - 15 5 - 15
NC 8 - 15 -
Range of control voltage Uc % 85 … 110
Control voltages Uc V 12 … 600
Terminal capacity
rigid
S mm2
0.75 … 4
flexible 0.5 … 2.5
Screw M3.5
Screw head PZ2
Tightening torque Nm 1.4
TECHNICAL DATA MOTOR CONTACTORS
KNL CONTACTORS
KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30
|