video corpo

Induction heating capacitors
24Pages

{{requestButtons}}

Catalog excerpts

Induction heating capacitors - 1

High Voltage Power Induction Heating

Open the catalog to page 1
Induction heating capacitors - 2

Iskra Kondenzatorji

Open the catalog to page 2
Induction heating capacitors - 3

General information on Iskra Capacitors Type Page Induction heating capacitors KLS 4 WATER COOLED CAPACITORS 180-10000 Hz 7 High voltage power capacitors KLV 13 High voltage power capacitors with two outputs KLV xxx4 18 SINGLE-PHASE CAPACITORS WITH TWO OUTPUTS 19 Iskra Kondenzatorji

Open the catalog to page 3
Induction heating capacitors - 4

Induction heating capacitors KLS loss KLS capacitor units is ALL-FILM capacitor sections environmentally compatible designed for inductive heat generating plants operating at request, these capacitors are designed to comply with the specific requirements of each customer. Most of these capacitors provide for step changes in kvar by virtue of terminated sections within each unit. This allows for the tuning of the circuit for changing inductive loads. polypropylene film and aluminum foil construction with NON- impregnating fluid M/DBT and textured polypropylene film have exceptional...

Open the catalog to page 4
Induction heating capacitors - 5

Quality Assurances following routine tests: • Sealing test on container. • Short circuit discharge test discharge, for internally fused • Capacitance measurements. • Voltage test between terminals • Voltage test terminals to container where applicable. Capacitors comply with EC Iskra Kondenzatorji

Open the catalog to page 5
Induction heating capacitors - 6

1. For output and voltage outside this range, please contact factory. Case sizes are typical and actual sizes will be confirmed at the time of order. Arrangement of bushings shown are for reference only 2. Power at 60 Hz = 1,2 times power at 50 Hz. Iskra Kondenzatorji

Open the catalog to page 6
Induction heating capacitors - 7

WATER COOLED CAPACITORS, 180-10000 Hz Picture 2 - Single Cooling Coil Capacitor (Insulated Poles, "DeacTCase) cooling coils pressure switch Cooling coil Common terminals with

Open the catalog to page 7
Induction heating capacitors - 8

Single cooling coil capacitors (typical sizes) 1. For output, frequency and voltage outside this range, please contact factory. Case sizes are typical and actual sizes will be confirmed 2. Arrangement shown are typical. Arrangements available are from 1 to 8 taps. Iskra Kondenzatorji

Open the catalog to page 8
Induction heating capacitors - 9

Picture 3 - Single Cooling Coils Capacitor ("Live" Case) Picture 4 - Double Cooling Coils Capacitor Iskra Kondenzatorji

Open the catalog to page 9
Induction heating capacitors - 10

Double cooling coil capacitors 1. For output, frequency and voltage outside this range, please contact factory. Case sizes are typical and actual sizes will be confirmed Iskra Kondenzatorji

Open the catalog to page 10
Induction heating capacitors - 11

Internal devices Number of terminals, connection Iskra Kondenzatorji

Open the catalog to page 11
Induction heating capacitors - 12

Ordering data: When ordering, please state: While every care is taken to ensure that the information contained in this publication is correct, no legal reserves the right to alter or modify the information contained herein at any time in the light of technical or other developments. Iskra Kondenzatorji

Open the catalog to page 12
Induction heating capacitors - 13

High voltage power capacitors KLV capacitor sections, improved connections between sections and impregnation with environmentally reactive power compensation of electrical networks and industrial plants. When required voltages are higher then rated voltage of individual capacitor, units are integrated into banks by means of series connection. Fusing is provided according to national requirements. Owing to high partial discharge inception voltage, KLV capacitors networks with higher harmonics and transient voltages. Low temperature- dependent capacitance change makes them particularly...

Open the catalog to page 13
Induction heating capacitors - 14

Single-phase capacitors terminal clamps * Dimensions with an asterisk (*) refer to internally fused capacitors 1) Internal fuses recommended 2) For output and voltage outside this range, please contact factory 3) Case sizes are typical and actual sizes will be confirmed at the time of order 4) Dim A may expand up to 115 % due to thermal flexure Iskra Kondenzatorji

Open the catalog to page 14
Induction heating capacitors - 15

Table I: Single-phase capacitors, 50 Hz standard units Iskra Kondenzatorji

Open the catalog to page 15
Induction heating capacitors - 16

Three-phase capacitors Picture 2 (dimensions in mm) Picture 3 (dimensions in mm) Iskra Kondenzatorji

Open the catalog to page 16
Induction heating capacitors - 17

Table II: Three-phase capacitors, 50 Hz standard units 1) For output and voltage outside this range, please contact factory 2) Case sizes are typical and actual sizes will be confirmed at the time of order 3) Internally fused capacitors on demand 4) Pressure switch on demand 5) Either 2 or 4 fixing brackets are used, depending on the height of the unit. Special bracket positions can be provided if required Please specify at the enquiry stage. 6) Dim A may expand up to 115 % due to thermal flexure Table III : Aplication of standard three-phase 50 Hz units at other operating voltages Values...

Open the catalog to page 17
Induction heating capacitors - 18

High voltage power capacitors capacitor sections, improved connections between sections environmentally compatible in sets of three to provide an economical unbalance detection scheme. This is particularly capacitor banks. Dielectric: All-film Impregnating fluid: Environmentally compatible impregnating oil based on M/DBT Discharge resistor: Built in discharge resistor reduces capacitor from the crest of rated Case material/Finish: Capacitor case is made of stainless steel and coated with primer and top coat. For indoor mounting are available capacitors made of ordinary steel case, coated...

Open the catalog to page 18
Induction heating capacitors - 19

Single-phase capacitors with two outputs Mounting slot Table IV - Power capacitors with two outputs 1) For output and voltage outside this range, please contact factory. 2) Case sizes are typical and actual sizes will be confirmed at the time of order 3) Either 2 (standard) or 4 (on demand) fixing brackets may be used. Special bracket positions can be provided if required Please specify at the enquiry stage. 4) Dim A may expand up to 115 % due to thermal flexure. Iskra Kondenzatorji

Open the catalog to page 19
Induction heating capacitors - 20

Type designation data: Internal devices Case material and finish Number of terminals, connection Production programme - polyester film capacitors, - polypropylene film capacitors, Capacitors and filters for radio interference suppression Spark suppression capacitors for motor cars Motor running &motor starting Lamp capacitors Power factor capacitors and automatic power factor banks Power factor controller Induction heating capacitors Tools and production equipment Iskra Kondenzatorji

Open the catalog to page 20
Induction heating capacitors - 21

Ordering data: When ordering, please state: While every care is taken to ensure that the information contained in this publication is correct, no legal reserves the right to alter or modify the information contained herein at any time in the light of technical or other developments. Iskra Kondenzatorji

Open the catalog to page 21

All Iskra d.d. catalogs and technical brochures

  1. eMis

    27 Pages

  2. ECU

    2 Pages

  3. NEO 3000

    37 Pages

  4. FPC 200

    4 Pages

  5. NFIF

    4 Pages

  6. NFIB

    4 Pages

  7. FI, NFI

    2 Pages

  8. MCE940 SCADA

    4 Pages

  9. Energy Sector

    52 Pages

  10. Product line

    20 Pages

  11. Energy meters

    44 Pages

Archived catalogs