Hydrosteel 7000 Brochure - ION Science - #2

/ 2


catalogue search
P. 01
P. 02
Pages:


See other catalogues for ION Science

Text version of the page
teCHniCAl speCiFiCAtion MeAsUreMent prinCiple Continuous hydrogen collection and analysis stAndArd CoMponents Hydrosteel 7000 analyser: includes all sensing, pneumatic, electrical and diagnostic circuits. Solid impact resistant GRP IP66 rated enclosure with support holes for racking, gland connectors for power input, thermocouple input, 2 x 4-20 mA output. Flux and ambient gas and thermocouple inputs. Non-intrusive probes: Hydrostell AT-F for use on steel from -40 oC to 500 oC, includes magnetic and banding attachment means for attachment to steel >4” diameter. Conduit: Incorporates ambient and flux sample and K-type thermocouple, up to 20 ft or 6 m. Software: Enabling downloading of internally stored data via RS-232 in a safe area or with a permit in hazardous areas. CertiFiCAtions Ingress protection rating IP66 II 2G EEx ia IIC T4 Baseefa 04ATEX0205 -20 oC < = T ambient < = +60 oC US Equivalent NEC 505 Class 1, Zone 1, Gas Group B, T4 NEC 500 Class 1, Division 1, Gas Group B, T4 ACCUrACy Logged and output data: ± 10% logged reading ± resolution response < 3 minutes resolUtion 1 pl/cm2/s (AT-S probe) (note 1 pl = 10.12 Litres at s.t.p) dynAMiC rAnGe AT-F probe: 0 to 2000 pl/cm2/s dAtA loGGinG Via analog outputs or internally CAliBrAtion At factory. Checked with CalCheck Hydrogen operAtion 24 V (accepts 15 – 26 V) d.c. teMperAtUre Analyser: -20 oC to 55 oC (-4 oF to 131 oF) Probe: steel surface up to 500 oC diMensions Analyser (excluding ports): 4” x 7” x 10”, or 10 x 16 x 26 cm AT-F probe: 6” or 15 cm diameter WeiGHt Analyser: less than 5.75 lb or 2.6 kg Conduit and collector: less than 5.75 lb or 2.6 kg ION SCIENCE is ISO9001:2008 certified Part number HS7 V2.2 This publication is not intended to form the basis of a contract and specifications can change without notice. EMC tested to EN61000-6-3 & EN61000-6-1 2001 Designed to function in the harshest of environments, Hydrosteel 7000 is operational in dust storms, heavy wind and rainfall and ambient temperatures varying between –20 oC to 55 oC, -4 oF to 131 oF . The instrument is also suitable for use in environments containing ambient variable levels of volatile organic compounds (VOCs), hydrogen and humidity. The need for a fixed hydrogen flux monitor emerged from findings that corrosion is often highly episodic and continuous monitoring is required at most high criticality sites, especially at times of high flux incidents which often occur during process upsets when inspection staff are not available. Hydrogen flux measurements relates directly to active sour and HF corrosion and any acid corrosion (e.g. sulfidic-naphthenic acid) at higher temperatures, and is designed for fixed monitoring. Typical locations for monitoring include: • Sour gas lines • Amin treatment plants • HF alkylation units • Delsufurisation units • Distillation outlets and heat exchangers • Distillation and cracking unit overheads Applications include: • Corrosion control • Feedstock blending • HIC damage reduction and control • Sour, HF acid and high temperature corrosion monitoring • Risk based inspection of prospective hydrogen damage For further information and ordering please call: tel: +44 (0) 1763 208 503 email: info@ionscience.com www.ionscience.com ION SCIENCE LIMITED The Way, Fowlmere, Cambs. SG8 7UJ, UK

pageCatalog pdf di En 2012-05-22-30