FirstCheck Brochure - ION Science - #4

/ 4


catalogue search
P. 01
P. 02
P. 03
P. 04
Pages:


See other catalogues for ION Science
You may also be interested in

Corrosion gauge, Detector, Leak detector, Analyzer, Gas analyzer


Text version of the page
Feature Detection range 0.1 – 4000 ppm Detection range 0.1 – 10,000 ppm Detection range 1 ppb – 10,000 ppm Intrinsically safe Health & Safety mode for STEL and TWA monitoring IRDA for wireless communications with a PC Auto range ppm/ppb Real-time graph display on screen Simple data store Data logging Date and Time stamp Interactive Ion PC software for instrument configuration and data handling Easy-to-use graphical icon based interface Zone name creator Audible alarm 90 dBA Visual alarm (LED) Gas table of 250+ gases and their individual response factors Selectable mg/m3 or ppm/ppb 1000 1000Ex 2000Ex 3000Ex 5000Ex Features and upgradeability options Key: Standard feature = Upgradeable = Note: Ion PC software runs on Windows XP and Vista FirstCheck+ Sensor Specifications Detector Range Response Time PID (VOC detector) FirstCheck+ 1000 T90 < 1 seconds Ion Science photoionisation & 2000 0.1 to cell fitted with Fence Electrode 4000 ppm Technology FirstCheck+ 3000 10.6 eV Krypton PID Lamp & 5000 0.1 to supplied as standard (others 10,000 ppm available - contact us for alternative lamps) Oxygen, O2 – Electrochemical sensor 0 to 28% T90 < 15 seconds Carbon monoxide, CO – 1 to 1000ppm T90 < 15 seconds Electrochemical sensor Hydrogen sulphide, H2S – 0.1 to 100 ppm T90 < 20 seconds Electrochemical sensor TECHNICAL SPECIFICATION DETECTOR For details of each sensor, its range and response time please see the FirstCheck+ Sensor Specification table. INTRINSICALLY SAFE APPROVALS II2 G Baseefa 03ATEX0742 Ex iad IIC T4 (-20 oC Ta 60 oC) IECEx BAS 04.0033 (world standard) ACCURACY* ± 5% displayed reading at calibration point LINEARITY* ± 5% DATA LOGGING Automatically recording all 5 sensors every second including date and time stamp 8 Mb (expandable) data memory Incorporates a secure storage algorithm to reduce stored data corruption CALIBRATION Via calibration kit accessory OPERATION Dry Cell: Alkaline 4 x AA:11 hours ALARM Flashing LED and 90 dBA (10cm) audible sounder User set and TWA & STEL Pre-programmed 450+ gases and gas mixtures FLOW RATE 220 ml/min or 220 cc/min with flow fail alarm TEMPERATURE Operating: -20 to 60 oC, -4 to 140 oF Humidity: 0-99% RH (non condensing) WEIGHT & DIMENSIONS Instrument without probe 340 x 60 x 49 mm (13.5 x 2.3 x 1.9”) Standard case 420 x 320 x 97 mm (16.5 x 12.5 x 3.8”) Instrument 0.615 kg (1.36 lb) Packed 3.045 kg (6.7 lb) NB: PID specifications relate to an isobutylene 100 ppm in air calibration at 20 oC and 90% RH. LEL specifications relate to a methane (CH4) calibration, other gases available on request. Other gas sensors as specified at appropriate international alarm standards. *Assuming constant environmental conditions Note: Fence Electrode Technology is produced by Ion Science Ltd, and protected by U.S. Patent No. 7,046,012. EP 1474681, other patents pending. 4992 12/08. Part number FCV3.5 This publication is not intended to form the basis of a contract and specifications can change without notice. ION SCIENCE is ISO9001:2008 certified For further information and ordering please call: Tel: +44 (0) 1763 208 503 Email: info@ionscience.com www.ionscience.com ION SCIENCE LIMITED The Way, Fowlmere, Cambs. SG8 7UJ, UK

pageCatalog pdf di En 2012-05-22-30