teChniCal SPeCiFiCation ConStrUCtion All stainless steel including sinter 1/8 BSP inlet and outlet threads aCCUraCY ± 2 % of certified leak rate inlet PreSSUre Maximum 20 bar Minimum 20 mbar leak rate SPeCiFiCationS Maximum 10 l/min Minimum 1 x 10-4 ml/sec By using a concentration of the target gas in an inert background minimum leak rates of 1 x 10-7 ml/sec are obtainable inForMation reQUired When orderinG Leak rate required in ml/sec, mm/min or ml/hr Inlet pressure in mb, bar or psig Gas to be used with leak e.g. air, helium etc. ION SCIENCE is ISO9001:2008 certified Part number CalLeak V1.3 This publication is not intended to form the basis of a contract and specifications can change without notice. Ion Science calibrated leaks are produced in order for a known leak to be presented to a test system. Should the leak be detected by your gas / leak detector at the correct value then the system is within calibration, giving you confidence in the accuracy of the instruments upon which you depend. At Ion Science we can produce calibrated leaks that are made to your individual pressure and leak rate specification. Each leak is supplied in its own storage box with a certificate of calibration traceable to our ISO9001:2000 procedures, using equipment, which is traceable UKAS / NIST. By ensuring our own quality standards we can help you to meet yours. For exeptional stability over time and resistance to corrosion and contamination, all leaks are made from stainless steel. The body has a standard 1/8 BSP inlet and outlet thread and can be supplied with a quick fit staubli fitting, for use with leak testers. The simple screw in screw out functionality of the calibrated leak is ideal when returning your leak to Ion Science for annual calibration as the leak can be easily removed, placed in its storage box and sent in the post. Ion Science calibrated leaks can be used in conjunction with our CalCheck accessory, an easy to use self calibration instrument. Multiple calibrated leaks can be ordered for use with a CalCheck. Simply unscrew your leak from the base and replace it with a different leak rate. This allows you to conveniently calibrate your instruments to a wide variety of leak rates and gases. For further information and ordering please call: tel: +44 (0) 1763 208 503 email: info@ionscience.com www.ionscience.com ION SCIENCE LIMITED The Way, Fowlmere, Cambs. SG8 7UJ, UK

pageCatalog pdf di En 2012-05-22-30