ACCURACY - (MAX ERROR)
Nonlinearity-% FS..............................±0.05
Hysteresis-% FS................................±0.03
Nonrepeatability % RO......................±0.02
Creep, in 20 min-%............................±0.025
TEMPERATURE
Compensated Range-'F......................0 to 150
Compensated Range-'C......................-15 to 65
Operating Range-'F............................-65 to 200
Operating Range-'C ..........................-55 to 90
Effect on Output-%/'F - MAX..............±0.0008
Effect on Output-%/'C - MAX..............±0.0015
Effect on Zero-% RO/'F - MAX............±0.0015
Effect on Zero-% RO/'C - MAX............±0.0027
ELECTRICAL
Rated Output-mV/V (Nominal)............3
Zero Balance % RO............................±1
Bridge Resistance-Ohm (Nominal) ....350
Excitation Voltage - MAX....................15 VDC
Insulation Resistance-Megohm..........> 5000
MECHANICAL
Calibration..........................................Tension
Safe Overload % CAP ........................150
Cable length-ft....................................10
Natural Frequency/Deflection:
Ibf N Deflection Nat. Freq.
(inches) (Hertz)
50 200 .003 1500
100 500 .004 1850
150 500 .004 1850
250 1000 .006 2350
500 2kN .005 2150
750 n/a .005 2350
1000 5kN .005 3350
2000 10kN .005 2400
3000 n/a .005 3000
5000 20kN .005 2520