Group: Instron
Catalog excerpts
Environmental Chambers 3119-600 Series
Open the catalog to page 13119 Series Environmental Chambers
Open the catalog to page 2Integration 3119-600 Series Environmental Chambers are designed to fit between the columns of a materials testing machine on a suitable mounting. Ports located in the upper and lower surfaces of the chamber allow pull rods to be inserted to which grips and fixtures are attached for operation within the chamber. Both fixed and roller mountings are available for the Instron range of Static and Dynamic Testing Machines. Chambers can also be fitted to other makes of testing machines, with custom mountings if desired. ®
Open the catalog to page 3Challenges in Non-Ambient Testing How 3119-600 Series Chambers can Help You How can Your Lab be More Efficient? • Rapid heat-up and recovery times mean you can test more specimens per day • Dual window heaters ensure optimum clarity at low temperatures giving more useful test time when using non-contacting extensometers or other optical devices • Automated soak time control - via software - allows you to perform other tasks while the system reaches set-point • Removable wedge-ports and roller mountings ensure simple and rapid changes of test configurations How can My Lab Become Safer? •...
Open the catalog to page 4How can I make Testing Easier for My Operators? • Just enter the desired set-point and go • Auto-tuning temperature controller gets you to set-point quickly without the need to adjust other parameters • Integration with Bluehill® 3 (v3.xx and above), Bluehill Universal, and WaveMatrix™ Software programs allows the chamber to be controlled directly from the same PC as your testing system • No need to manually re-enable after changing specimens; closing the chamber door automatically re-starts the fan and heating/cooling functions • Instrumentation slot in the wedge-ports makes using...
Open the catalog to page 5Temperature Control Heating is achieved by passing air over an electrically heated element. All chambers in the range come with heating as standard. Cooling is achieved by blowing cryogenic gas (either CO2 or LN2) into the chamber via an optional cooling valve. The cryogenic gas is normally stored in cylinders (liquid CO2) or a self-pressurizing Dewar (liquid N2). Waste cryogenic gas is exhausted to the rear of the chamber through a dedicated port to which a silicone rubber pipe can be attached and vented outside the laboratory environment. Specimen Access Access to the specimen and grips...
Open the catalog to page 6Optional Accessories for a Complete Testing Solution Power Supply & Temperature Control Equipment The 3119-600 chamber range provides reliable and enduring performance over a vast range of testing applications where non-ambient testing conditions are needed. However, a chamber alone is not sufficient. Instron ® offers a comprehensive line of grips, fixtures, extensometers, and pull rods to ensure a complete solution to your test requirements. Chamber Impeller Operating Principles • Full range of pull rods, push rods, extensometers, grips, and fixtures for use at high and low temperatures...
Open the catalog to page 7Great Features with Real Benefits Enhance Ease of Use, Safety, and Applications Coverage Temperature Ramp 1 Starting Setpoint Start Advanced functions include 8-segment Ramp/Dwell, USB interface, and Analog DC output capability Program Running Internal light makes test area easily visible when the door is closed. Removable wedge ports provide quick and easy loadstring setup and incorporate instrumentation cut-outs for extensometer cables without interfering with the pull rods. Dedicated cryogen exhaust port makes safe venting simple.
Open the catalog to page 8• Full 3-term PID temperature controller with auto-tune combines simplicity and flexibility to cover a range of testing requirements. • Selectable slow fan speed improves testing of delicate specimens at low forces by reducing air turbulence. • Interlock switch on floor model chambers for water-cooled grips shuts chamber down automatically if water flow is interrupted. Triple-pane, optical quality borosilicate glass window with twin cartridge heaters for minimizing frosting and misting when testing at low temperatures. Fully compatible with Instron ® non-contacting video extensometers for...
Open the catalog to page 9TABLE MODELS FLOOR MODELS Maximum Temperature Minimum Temperature (Requires Cooling Option) Heat-Up Time to Maximum or Stated Temperature from Ambient Including Typical Load String Better than 50 Minutes (120/240V) Better than 100 Minutes (100/200V) Better than 50 Minutes (120/240V) Better than 100 Minutes (100/200V) Better than 25 Minutes (240V) Better than 35 Minutes (200V) Better than 60 Minutes (240V) Typically 120 Minutes to 250°C (Depending on load string) Typically 120 Minutes to 250°C (Depending on load string) Typically 120 Minutes to 250°C (Depending on load string) Heating Method...
Open the catalog to page 10TABLE MODELS FLOOR MODELS Internal Height External Width Internal Width External Depth Internal Depth Pull Rod Port Diameter Pull Rod Port Center to Inside Rear Pull Rod Port Center to Inside Front Window Height Window Width Weight Working Space TABLE MODELS Overall System Accuracy Notes: 1. Includes reducer to 67 mm FLOOR MODELS Working Space
Open the catalog to page 11“True innovation occurs when product designers and developers show relentless curiosity towards the needs of their customers. This builds an understanding that allows them to anticipate and create a new suite of solutions that are Simpler, Smarter, and Safer.” Yahya Gharagozlou Group President ITW Test & Measurement Instron is a registered trademark of Illinois Tool Works Inc. (ITW). Other names, logos, icons and marks identifying Instron products and services referenced herein are trademarks of ITW and may not be used without the prior written permission of ITW. Other product and company...
Open the catalog to page 12All Instron catalogs and technical brochures
-
Composites Testing Solutions
20 Pages
-
2580 Series Load Cells
3 Pages
-
HDX Models
2 Pages
-
DX MODELS
4 Pages
-
INDUSTRIAL SERIES DX MODELS
4 Pages
-
DAMPER TEST SYSTEMS BI-7080
2 Pages
-
HIGH STRAIN RATE VHS SYSTEM
4 Pages
-
Automated XY Testing System
3 Pages
-
CEAST 9400 Series
20 Pages
-
COMPRESSION PLATENS
2 Pages
-
LOW CYCLE FATIGUE
11 Pages
-
ElectroPuls™
10 Pages
-
Pneumatic Side-Action Grips
4 Pages
-
CEAST MF Series
20 Pages
-
HDT AND VICAT TESTING SYSTEMS
16 Pages
-
AlignPRO™ Alignment System
2 Pages
-
CEAST Melt Flow Series
20 Pages
-
CEAST SmartRheo Series
16 Pages
-
CEAST 9000 Series
20 Pages
Archived catalogs
-
CEAST HDT Vicat Series
9 Pages