OPC Server Modbus on TCP
The OPC Server Modbus on TCP may be used for all devices and
Supplier of plcs, that support the Modbus on TCP protocol. These are PLCs from Schneider Electric as well as interface connections from different manufacturers e.g. Beckhoff, Wago, Phoenix etc. It can be used also to access S7 PLCs, that use an Ethernet-MPI/PPI
professional gateway (e.g. netLINK) instead of a communication processor (CP). â–º For various Modbus on TCP interface connections â–º For INAT CPs ( ONLY Modbus- and Send / Receive communication) â–º Works with IBH Link and netLINK â–º Easy import of Step >
® 7 symbolic names directly from the Step >
® 7 project TRANSPORT PROTOCOLS:APPLICATION PROTOCOLS: TCP/IP, TCP/IP with PLC HeaderModbus on TCP, Send / Receive, netLINK / netLINK Plus Other: FOR: Devices with Send / Receive interface INAT: S5-TCP/IP-100, echolink (e.g. with S5-95U) Modbus on TCP interfaces: All interfaces, that support the following Modbus on TCP func-tion codes : 01 Read coil 02 Read discrete input
03 Read holding register
04 Read input register
05 Write single coil
06 Write single register
15 Write multiple coils
16 Write multiple registers Operating systems:Windows NT / 2000 / XP / 2003 / Vista >
OPC Client OPC Client OPC Server Modbus on TCP
Modbus on TCPSend / Receive Modbus on TCP Devices with
Ethernet Interface Modbus Devices INAT Test fi rst, then license! At www.inat.de a 72h version of all OPC Servers is available Order data:Single user license Order number: 100-3140-01 Single user license incl. USB dongle Order number: 100-3140-20 Upgrade Order number: 100-3140-Upg Upgrade incl. USB dongle Order number: 100-3140-Dgl – OPC Server Page 6 –