FlowAnalyserTMTechnical DataPF-300 PF-301 PF-302 Flow & Pressure MeasurementsRangeAccuracy 300.718.000 | 08.08 FlowMeasuring directionbidirectional Temperature compensatedyes Pressure compensatedyes Humidity compensatedyes O 2 compensatedyes High± 300 L/min± 1.75 %* or ± 0.1 L/min** Low± 20 L/min± 1.75 %* or ± 0.04 L/min** PressureHigh 0 - 10 bar± 1 %* or ± 10 mbar** Average± 150 mbar± 0.75 %* or ± 0.1 mbar** DifferenceRelativeRelative Low 0 - 5 mbar ± 1 %* or ± 0.01 mbar** High in Flow Canal0 - 150 mbar ± 0.75 %* or ± 0.1 mbar** Barometer0 - 1150 mbar (abs) ± 1 %* or ± 5 mbar** Vacuum pressure± 1000 mbar ± 0.5 %* or ± 2 mbar** Measuring unitFlowL/min, L/s, cfm, mL/min, mL/s Pressurebar, mbar, cmH 2 O, inH 2 O, Torr, inHg, hPa, kPa, mmHg, PSI Additional Measuring Values RangeAccuracy OxygenConcentration0 - 100 %± 1 % O 2 ** Pressure compensatedyes TemperatureHigh in Flow Canal0 - 50°C± 1.75 %* or ± 0.5°C** Dew pointHigh in Flow Canal-10 - 50°C± 2 %* or ± 1°C** Air humidityHigh in Flow Canal0 - 100 %± 3 %** CO 2 Concentration0 - 20 %± 8 %* or ± 0.3 %** with OR-703with OR-703with OR-703 N 2 OConcentration0 - 100 %± 8 %* or ± 2 %** with OR-703 with OR-703 with OR-703 HAL, ISO, ENFConcentration0 - 12 %± 8 %* or ± 0.2 %** with OR-703 with OR-703 with OR-703 SEVConcentration0 - 15 %± 8 %* or ± 0.2 %** with OR-703 with OR-703 with OR-703 DESConcentration0 - 22 %± 8 %* or ± 0.2 %** with OR-703 with OR-703 with OR-703 Gas typesAir, Air/O 2 , N 2 O/O 2 , Heliox (21% O 2 ), He/O 2 , N 2 , CO 2 , customized gas types Gas StandardisationATP, ATPD, ATPS, AP21, STP, STPH, BTPS, BTPD,0/1013, 20/981, 15/1013, 25/991, 20/1013 Respiratory Parameters 1) RangeAccuracy Rate1 - 1000 bpm/min±1 bpm or ± 2.5 %** TimeT I ,T E 0.05 - 60 s± 0.02 s I:E ratio1:300 - 300:1± 2.5 %* Ti/Ttotal0 - 100 %± 5%* Breath volumesVti, Vte± 10 L± 2 %* or ± 20 mL** Minute volumesVi, Ve0 - 300 L/min± 2.5 %* PressureP peak , P mean , PEEP, P plateau 0 -150 mbar± 0.75 %* or ± 0.1 mbar** PeakflowPeakflow Insp./Exp.± 300 L/min± 1.75 %* or ± 0.1 L/min** ComplianceC stat 0 - 1000 mL/mbar± 3 %* or ± 1 mL/mbar** TriggerAdult, Pediatric, HFOAdjustable on flow or pressure curves with user-defined limits. General Information Electrical & AC input90 - 260 VAC, 50/60 Hz Physical DataBattery (lead rechargeable battery)3 hrs (with OR-703 2 hrs) Power consumption23 VA Weight3.7 kg Dimensions (w x d x h)22 x 25 x 12 cm Data Storage a ll parameters (measured as well as respiratory values) DisplayGraphic displayIntuitive user interface with numerical measuring values, statistics, volume trigger configuration, gas type selection and calibration menus.CommunicationUSB for Windows Software FlowLab TM , InterfacesRS-232 for individual communication, TTL for external trigger.Calibrationannually ConditionsAmbient temperature10 - 40°C (50 - 104°F) Humidity10 - 95 % R.H.*** ApprovalsCE, CSA Legend *Tolerance related to the measured value ** Absolute tolerance FlowAnalyser Brochure EN - 58469 }The greater tolerance is valid*** Non-condensing 1) Tolerance related to the optimal calibration of the triggerSubject to technical changes. Release: 05.2007 imtmedical ag Gewerbestrasse 8 9470 Buchs SG Switzerland T:+41 81 750 66 99 F:+41 81 750 66 95 www.imtmedical.com |
|