| | | www.imeitaly.com | | |
| | | |
| | | Energy meters Single-phase l.v. network Direct connection current 36A Direct connection voltage 230-240V Active energy cl.1 2 module housing | | |
| | | |
| | | Conto D2-b | | |
| | | |
| | | ® | | |
| | | Single-phase l.v. network Direct connection current 36A e 63A Direct connection voltage 230-240V Total and partial active energy cl.1 Current, voltage, active power Pulse output (option) 2 module housing | | |
| | | |
| | | * ■ * Conto D2 | | |
| | | |
| | | |
| | | Single-phase and three-phase l.v./M.V. network Current CT/1A and /5A (same model) programmable ratio Direct connection voltege up to 440V (phase-phase) or on VT programmable ratio Total and partial active energy cl.1 Total and partial reactive energy cl.2 Power demand and max. power demand Pulse output (kWh or kvarh) and/or RS485 communication (option) 4 module sealable housing Version for UTF fiscal use with built-in run hour meter (with activating threshold) | | |
| | | Conto D4-Pt Conto D4-Pt UTF | | |
| | | |
| | | |
| | | | | |
| | | Three-phase l.v. network Direct connection current 63A Direct connection voltage up to 440V (phase-phase) Active energy cl.1: total and partial or double tariff Reactive energy cl.2: total and partial or double tariff Power demand and max. power demand Pulse output (kWh or kvarh) or RS485 communication (option) 4 module sealable housing Version for UTF fiscal use with built-in run hour meter (with activating threshold) | | |
| | | |
| | | Conto D4-Pd Conto D4-Pd UTF | | |
| | | |
| | | |
| | | ® | | |
| | | Single-phase and three-phase l.v./M.V. network Direct connection current up to 25A or on CT /1A or /5A Direct connection voltege up to 440V (phase-phase) or on VT Active energy cl.2 or cl.1 Reactive energy cl.3 or cl.2 Pulse output Flush mounting housing, 96x96mm front frame | | |
| | | |
| | | |
| | | Conto 96 | | |
| | | |
| | | Interface for energy meters Pulse concentrator 8 independent and non-resettable count records 8 contact inputs coming from energy meters RS485 serial output JBUS/MODBUS protocol 4 module housing | | |
| | | |
| | | Conto IF | | |
| | | |
| | | Software | | |
| | | |
| | | Program for Windows 95/98/NT/2000/XP for network monitoring with Conto. series meters. Reading of energy consumption, measured consumption costing, data export in electronic sheets. | | |
| | | |
| | | Conto | | |
| | | |
| | | COMMUNICATION | | |
| | | | | |
| | | |
| | | W.02 | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |