ZU series
6Pages

{{requestButtons}}

Catalog excerpts

ZU series - 1

IMADA.CO.,LTD High Capacity Tension Load Cell ZU series/ZW1-10kN High Capacity Tension Load Cell ZU series/ZW1-10kN - Ideal load cells for high capacity tension measurement - Easy to set up by included rod end (ZU series) or a hook (ZW1-10kN) - Works as a crane scale (ZW1-10kN) -Combine with IMADA’s amplifier (indicator), It can measure load changes due to the fluctuation. -It is easy to pull a sample by the shaft inserted to each rod end (ZU series) or a hook (ZW1-10kN) -Due to the separated sensor and indicator (amplifier), the test result can be check at a remote place. * Refer to next page for details. What is IP? IP(International Protection) is a standard which is based on IEC Standard 529 for solid foreign materials, electric devices for water and cabinet. IP67 IP×× The second code (IP 0 to 8 for water penetration) The first code (IP 0 to 8 for human body and sold foreign materials) Ingress of water in harmful quantity shall not be possible when the enclosure is immersed in water under defined conditions of pressure and time (up to 1m of submersion for 30 minutes.) No ingress of dust, complete protection against contact. : eZ-Connect series eZ-Connect is composed of an amplifier and load cells. -Allows easy replacement of load cells without additional adjustment -Suits different types of tests such as tension and torque, measuring from low load to high load, etc. Available load cells have a mark.

Open the catalog to page 1
ZU series - 2

IMADA.CO.,LTD High Capacity Tension Load Cell ZU series/ZW1-10kN Specifications Model Rated output Allowable voltage Safe overload rating Working environment (allowable temperature) Approx. 0.5 to 4m (Curl cord) Temperature influence at 0 point Temperature influence for output *1 It is the accuracy of the load cell itself. See page 3 for the accuracy of combinations with the amplifier (indicator) under [Models of sensors combined with indicators (Separated sensor models)] and [eZ-Connect series (Sensor interchangeable model)]. *2 IP67 is only approved for the load cell itself. The amplifier...

Open the catalog to page 2
ZU series - 3

IMADA.CO.,LTD High Capacity Tension Load Cell ZU series/ZW1-10kN [Models of sensors combined with indicators (Separated sensor models)] ZU series Model * Refer to each indicator specification for details. *1 It is the accuracy of the sensor and the indicator combined. * Refer to each indicator specification for details. *1 It is the accuracy of the sensor and the indicator combined. [eZ-Connect series (Sensor interchangeable model)] Model Amplifier: eZT 10kN Load Cell: eZU-10kN Amplifier: eZT 20kN Load Cell: eZU-20kN eZU series Amplifier: eFA Plus2 10kN +/- 1.2% F.S. Load Cell: eZU-10kN or...

Open the catalog to page 3
ZU series - 4

IMADA.CO.,LTD High Capacity Tension Load Cell ZU series/ZW1-10kN Related Products High Capacity Load Cell High Capacity Load Cell Load cell DPU series is high capacity type for both tension and compression testing with 1000N to 20kN capacity. Load cell SW series is waterproof and dust-proof type for both tension and compression testing with 100N to 20kN capacity. Graphing Software: Force Recorder - You can make graphs of force-displacement at real time via USB connection at 2000Hz. - You can write memo on each graph. You may write down testing conditions such as testing speed. - 5 graphs at...

Open the catalog to page 4
ZU series - 5

IMADA.CO.,LTD High Capacity Tension Load Cell ZU series/ZW1-10kN [Dimensions] ZU series The nuts are attached to prevent loosening the rod ends.

Open the catalog to page 5
ZU series - 6

IMADA.CO.,LTD High Capacity Tension Load Cell ZU series/ZW1-10kN [Cautions] - Information in this document is subject to change without prior notice. - This document is product descriptions and handling precautions, and do not guarantee various characteristics or safety. - This product is designed for force measurement purpose only. - Do not copy and use this content without authorization. - Do not apply force more than its capacity or from incorrect direction to the measuring shaft. - Do not use this product in the environments including fierce temperature changes, high temperature, high...

Open the catalog to page 6

All IMADA catalogs and technical brochures

  1. KC series

    4 Pages

  2. ZTS series

    7 Pages

  3. ZTA series

    8 Pages

  4. FSA series

    7 Pages

  5. MTS series

    7 Pages

  6. XST-500N

    3 Pages

  7. TS-5000N

    3 Pages

  8. SHF series

    5 Pages

  9. GTW-2500N

    4 Pages

  10. CCJ series

    6 Pages

  11. DPU series

    7 Pages

  12. SKM-1000N

    6 Pages

  13. PGC series

    4 Pages

  14. DM-2000N

    6 Pages

  15. CBJ-200N

    4 Pages

  16. FBO-CFX

    3 Pages

  17. COF series

    7 Pages

  18. PK2-1500N

    4 Pages

  19. SW series

    7 Pages

  20. grp-50

    3 Pages

  21. P180-200N

    6 Pages

  22. P90‐200N

    7 Pages

  23. SK series

    6 Pages

  24. SCX series

    5 Pages

  25. CHX Series

    6 Pages

  26. TFX Series

    4 Pages

  27. FCA-DSV-50N

    4 Pages

  28. IPTS-20N/50N

    6 Pages

  29. SJS-100N-L/S

    5 Pages

  30. VWF-10N

    6 Pages

  31. APR-97

    3 Pages

  32. ZLINK4

    5 Pages

  33. SDT series

    4 Pages

  34. MED-NPT-200N

    4 Pages

  35. MED-ACU-2N

    3 Pages

  36. TKS-20N/250N

    6 Pages

  37. BT series

    6 Pages

  38. HV series

    5 Pages

  39. SQ series

    4 Pages

  40. CW-500N

    4 Pages

  41. Force logger

    5 Pages

  42. MED-IS-20N

    3 Pages

  43. FC series

    6 Pages

  44. EMX-1000N

    7 Pages

  45. MED-SCT-500N

    3 Pages

  46. WG series

    5 Pages

  47. GP-15/30

    4 Pages

  48. GC-60/100

    4 Pages

  49. FP-50/51

    3 Pages

  50. SP series

    4 Pages

  51. PG series

    4 Pages

  52. PC series

    4 Pages

  53. P45-50N

    4 Pages

  54. GC-5/15

    4 Pages

  55. CP-150N

    3 Pages

  56. FRTS series

    6 Pages

  57. MS series

    5 Pages

  58. PPC-5000N

    4 Pages

  59. DSV series

    6 Pages

  60. WL01 series

    5 Pages

  61. MH2 series

    6 Pages

  62. AMK series

    4 Pages

  63. ST-SS

    2 Pages

  64. SJ series

    6 Pages

  65. RSH series

    5 Pages

  66. HFC-50N

    4 Pages

  67. ZW1-10kN

    6 Pages

  68. CW-5000N

    4 Pages

  69. CH-5000N

    4 Pages

  70. LH-500N

    5 Pages

  71. UK series

    5 Pages

  72. PT series

    6 Pages

  73. FCA-50N

    3 Pages

  74. KV series

    3 Pages

  75. SH series

    5 Pages

  76. PSH series

    5 Pages

  77. PCA-150N

    3 Pages

  78. CH-5000N

    4 Pages

  79. FB/FS series

    5 Pages

  80. PSM series

    5 Pages

  81. SHT-5N

    3 Pages

  82. Force Gauges

    4 Pages

  83. DS2 series

    4 Pages

  84. LMU series

    8 Pages

  85. ZD series

    8 Pages

  86. F-S Master

    5 Pages

Archived catalogs

  1. ZTS series

    7 Pages

  2. ZTA series

    9 Pages

  3. FCA-DS2-50N

    3 Pages

  4. MX-1000N

    3 Pages

  5. MX-500N

    3 Pages

  6. HV-3000N

    3 Pages

  7. MS-50N

    4 Pages

  8. SV series

    4 Pages

  9. FA Plus

    4 Pages

  10. HV series

    3 Pages