Catalog excerpts
IMADA.CO.,LTD High Capacity Tension Load Cell ZU series/ZW1-10kN High Capacity Tension Load Cell ZU series/ZW1-10kN - Ideal load cells for high capacity tension measurement - Easy to set up by included rod end (ZU series) or a hook (ZW1-10kN) - Works as a crane scale (ZW1-10kN) -Combine with IMADA’s amplifier (indicator), It can measure load changes due to the fluctuation. -It is easy to pull a sample by the shaft inserted to each rod end (ZU series) or a hook (ZW1-10kN) -Due to the separated sensor and indicator (amplifier), the test result can be check at a remote place. * Refer to next page for details. What is IP? IP(International Protection) is a standard which is based on IEC Standard 529 for solid foreign materials, electric devices for water and cabinet. IP67 IP×× The second code (IP 0 to 8 for water penetration) The first code (IP 0 to 8 for human body and sold foreign materials) Ingress of water in harmful quantity shall not be possible when the enclosure is immersed in water under defined conditions of pressure and time (up to 1m of submersion for 30 minutes.) No ingress of dust, complete protection against contact. : eZ-Connect series eZ-Connect is composed of an amplifier and load cells. -Allows easy replacement of load cells without additional adjustment -Suits different types of tests such as tension and torque, measuring from low load to high load, etc. Available load cells have a mark.
Open the catalog to page 1IMADA.CO.,LTD High Capacity Tension Load Cell ZU series/ZW1-10kN Specifications Model Rated output Allowable voltage Safe overload rating Working environment (allowable temperature) Approx. 0.5 to 4m (Curl cord) Temperature influence at 0 point Temperature influence for output *1 It is the accuracy of the load cell itself. See page 3 for the accuracy of combinations with the amplifier (indicator) under [Models of sensors combined with indicators (Separated sensor models)] and [eZ-Connect series (Sensor interchangeable model)]. *2 IP67 is only approved for the load cell itself. The amplifier...
Open the catalog to page 2IMADA.CO.,LTD High Capacity Tension Load Cell ZU series/ZW1-10kN [Models of sensors combined with indicators (Separated sensor models)] ZU series Model * Refer to each indicator specification for details. *1 It is the accuracy of the sensor and the indicator combined. * Refer to each indicator specification for details. *1 It is the accuracy of the sensor and the indicator combined. [eZ-Connect series (Sensor interchangeable model)] Model Amplifier: eZT 10kN Load Cell: eZU-10kN Amplifier: eZT 20kN Load Cell: eZU-20kN eZU series Amplifier: eFA Plus2 10kN +/- 1.2% F.S. Load Cell: eZU-10kN or...
Open the catalog to page 3IMADA.CO.,LTD High Capacity Tension Load Cell ZU series/ZW1-10kN Related Products High Capacity Load Cell High Capacity Load Cell Load cell DPU series is high capacity type for both tension and compression testing with 1000N to 20kN capacity. Load cell SW series is waterproof and dust-proof type for both tension and compression testing with 100N to 20kN capacity. Graphing Software: Force Recorder - You can make graphs of force-displacement at real time via USB connection at 2000Hz. - You can write memo on each graph. You may write down testing conditions such as testing speed. - 5 graphs at...
Open the catalog to page 4IMADA.CO.,LTD High Capacity Tension Load Cell ZU series/ZW1-10kN [Dimensions] ZU series The nuts are attached to prevent loosening the rod ends.
Open the catalog to page 5IMADA.CO.,LTD High Capacity Tension Load Cell ZU series/ZW1-10kN [Cautions] - Information in this document is subject to change without prior notice. - This document is product descriptions and handling precautions, and do not guarantee various characteristics or safety. - This product is designed for force measurement purpose only. - Do not copy and use this content without authorization. - Do not apply force more than its capacity or from incorrect direction to the measuring shaft. - Do not use this product in the environments including fierce temperature changes, high temperature, high...
Open the catalog to page 6All IMADA catalogs and technical brochures
-
Force Recorder Next Series
8 Pages
-
Force Recorder Professional
7 Pages
-
Force Recorder Standard
7 Pages
-
OP-MX2EMX-IC/OP-MX250-IC
4 Pages
-
KC series
4 Pages
-
LM/LC/DD2/LMT series
7 Pages
-
CLFX / CFX Series
5 Pages
-
ZTS series
7 Pages
-
ZTA series
8 Pages
-
FSA series
7 Pages
-
FA Plus2 / eFA Plus2
11 Pages
-
HTGS/HTGA series
8 Pages
-
Specification list of cables
7 Pages
-
LMU/LU/ZD series
7 Pages
-
A-40/60,S-40/60
4 Pages
-
MTS series
7 Pages
-
XY-500N series
5 Pages
-
XST-500N
3 Pages
-
TS-5000N
3 Pages
-
SHF series
5 Pages
-
GTW-2500N
4 Pages
-
CCJ series
6 Pages
-
Vise Grips GT-30/2000N
4 Pages
-
DPU series
7 Pages
-
SKM-1000N
6 Pages
-
PGC series
4 Pages
-
DM-2000N
6 Pages
-
CBJ-200N
4 Pages
-
FBO-CFX
3 Pages
-
COF series
7 Pages
-
PK2-1500N
4 Pages
-
SW series
7 Pages
-
grp-50
3 Pages
-
P180-200N
6 Pages
-
P90‐200N
7 Pages
-
SK series
6 Pages
-
SCX series
5 Pages
-
CHX Series
6 Pages
-
Pen Type Load Cell PN-50N
4 Pages
-
Torque Load Cell eHT series
5 Pages
-
HTGS/HTGA-TFX Series
8 Pages
-
TFX Series
4 Pages
-
Driver Torque Meter I-8/I-80
4 Pages
-
FCA-DSV-50N
4 Pages
-
IPTS-20N/50N
6 Pages
-
Peeling Tester IPTS-5N
7 Pages
-
SJS-100N-L/S
5 Pages
-
VWF-10N
6 Pages
-
APR-97
3 Pages
-
Force Logger Plus
4 Pages
-
Force Recorder Plus
8 Pages
-
ZLINK4
5 Pages
-
SDT series
4 Pages
-
MED-LFA-20N/MED-VH-5N
4 Pages
-
MED-NPT-200N
4 Pages
-
MED-ACU-2N
3 Pages
-
TKS-20N/250N
6 Pages
-
BT series
6 Pages
-
GC-1100/1200/5000, GCF-1200
5 Pages
-
HV series
5 Pages
-
SQ series
4 Pages
-
CW-500N
4 Pages
-
Force logger
5 Pages
-
MED-IS-20N
3 Pages
-
FC series
6 Pages
-
EMX-1000N
7 Pages
-
MED-SCT-500N
3 Pages
-
WG series
5 Pages
-
GP-15/30
4 Pages
-
GC-60/100
4 Pages
-
FP-50/51
3 Pages
-
SP series
4 Pages
-
PG series
4 Pages
-
PC series
4 Pages
-
P45-50N
4 Pages
-
GC-5/15
4 Pages
-
CP-150N
3 Pages
-
Force gauge comparison table
4 Pages
-
Optional handle FOH
3 Pages
-
FRTS series
6 Pages
-
MS series
5 Pages
-
PPC-5000N
4 Pages
-
DSV series
6 Pages
-
WL01 series
5 Pages
-
Compression attachment table
3 Pages
-
MH2 series
6 Pages
-
PTW-10IN/OT-8IN
3 Pages
-
AMK series
4 Pages
-
Universal Joint UJ series
4 Pages
-
ST-SS
2 Pages
-
SJ series
6 Pages
-
RSH series
5 Pages
-
HFC-50N
4 Pages
-
ZW1-10kN
6 Pages
-
CW-5000N
4 Pages
-
CH-5000N
4 Pages
-
LH-500N
5 Pages
-
UK series
5 Pages
-
PT series
6 Pages
-
FCA-50N
3 Pages
-
PK1-500N series
4 Pages
-
KV series
3 Pages
-
SH series
5 Pages
-
PSH series
5 Pages
-
PCA-150N
3 Pages
-
CH-5000N
4 Pages
-
FB/FS series
5 Pages
-
PS/PSS series
5 Pages
-
PSM series
5 Pages
-
SHT-5N
3 Pages
-
180 degree Peeling Tester
5 Pages
-
Force gauge attachment
5 Pages
-
Force Gauges
4 Pages
-
DS2 series
4 Pages
-
LMU series
8 Pages
-
ZD series
8 Pages
-
F-S Master
5 Pages
-
Friction Testing System
1 Pages
-
Peel testing system
1 Pages
Archived catalogs
-
ZTS series
7 Pages
-
ZTA series
9 Pages
-
Wire Harness Pull Tester
3 Pages
-
FCA-DS2-50N
3 Pages
-
MX-1000N
3 Pages
-
MX-500N
3 Pages
-
HV-3000N
3 Pages
-
MS-50N
4 Pages
-
SV series
4 Pages
-
Tensile Load Cell ZW1-10kN
6 Pages
-
PK1-500N/PK2-1500N
4 Pages
-
FA Plus
4 Pages
-
HV series
3 Pages