1. Catalogs
  2. IMADA
  3. PK1-500N series

PK1-500N series
1 /4Pages

PK1-500N series

PK1-500N series
1 /4Pages

Catalog excerpts

PK1-500N series-1

IMADA CO.,LTD Special Use Load Cell PK1-500N/PK2-1500N Load cell for Two-wheeler Handbrakes PK1-500N Load cell for Vehicle Foot Pedals PK2-1500N Measure force acting on foot pedals or handbrakes. You can simply clip or mount on the load cell to perform measurements. Setting image *Grip the load cell and the brake together to measure force after mounting. Setting image *Clip a load cell onto a pedal and step them on together to measure force. What is IP? IP(International Protection) is a standard which is based on IEC Standard 529 for solid foreign materials, electric devices for water and cabinet. IP65 The second code (IP 0 to 8 for water penetration) The first code (IP 0 to 8 for human body and sold foreign materials) Water projected in powerful jets (12.5 mm nozzle) against the enclosure from any direction shall have no harmful effects at least for 3 minutes 100 liter per minute. No ingress of dust; complete protection against contact (dust tight) :eZ-Connect series eZ-Connect is composed of an amplifier and load cells. Enables to replace load cells without additional adjustment. Suitable for different types of tests such as tension and torque, measuring from low load to high load etc. Available load cells have a mark

 Open the catalog to page 1
PK1-500N series-2

IMADA CO.,LTD * An amplifier (indicator) is required to read values. Please refer to below “Available amplifiers (indicators)” for the detail. *1 The accuracy is only load cell itself. Please refer to below “Separated Sensor Model” and “eZ-Connect series” for the accuracy of combinations with the amplifier (indicator). *2 IP65 is only approved for the load cell itself. The amplifier (indicator) and the connector parts are not approved. *3 Refer to specification of [Options Available for Load cell Cable] to change cable length or so. [Connector Type] * When ordering only the load cell, PK1-500N...

 Open the catalog to page 2
PK1-500N series-3

IMADA CO.,LTD Special Use Load Cell PK1-500N/PK2-1500N [Separated Sensor Model] *1 Total accuracy when combined with the eZ-Connect series amplifier. e.g. Total accuracy of eCLFX and eZT +/-1.2%F.S. or less (Load cell: +/-1.0%F.S. or less + Amplifier: +/-0.2%F.S. or less) * Please refer to the accuracy of the sensor of eZ-Connect in the Specifications table. Coin shaped type High accuracy coin shaped type Standard type Coin size load cell for compression. High accuracy built-in type load cell for general use. High accuracy coin shaped load cell for compression. Extra small type Optional cables...

 Open the catalog to page 3
PK1-500N series-4

IMADA CO.,LTD Special Use Load Cell PK1-500N/PK2-1500N - Information in this document is subject to change without prior notice. - This document is product descriptions and handling precautions, and do not guarantee various - This product is designed for force measurement purpose only. - Do not copy and use this content without authorization. - Do not apply force more than its capacity or from incorrect direction to the measuring shaft. - Do not use this product in the environments including fierce temperature changes, high temperature, high humidity, near water, dusty place. 99 Jinnoshinden-cho...

 Open the catalog to page 4

All IMADA catalogs and technical brochures

  1. SH series

    5  Pages

  2. MS series

    4  Pages

  3. KV series

    3  Pages

  4. HV series

    5  Pages

  5. FCA-50N

    3  Pages

  6. GTW-2500N

    4  Pages

  7. WL01 series

    5  Pages

  8. P180-200N

    6  Pages

  9. SW series

    6  Pages

  10. VWF-10N

    7  Pages

  11. LMU/LU series

    6  Pages

  12. GP-15/30

    4  Pages

  13. KC series

    4  Pages

  14. DPUH series

    7  Pages

  15. DPU series

    7  Pages

  16. SHF series

    6  Pages

  17. SCX series

    5  Pages

  18. LM/LC series

    7  Pages

  19. CHX Series

    6  Pages

  20. TFX Series

    4  Pages

  21. SKM-1000N

    7  Pages

  22. DM-2000N

    7  Pages

  23. PK2-1500N

    4  Pages

  24. TS-5000N

    3  Pages

  25. APR-97

    3  Pages

  26. ZU series

    5  Pages

  27. FC series

    6  Pages

  28. MH2 series

    7  Pages

  29. FRTS series

    6  Pages

  30. CBJ-200N

    4  Pages

  31. SJS-100N-L/S

    5  Pages

  32. P90‐200N

    7  Pages

  33. MTS series

    7  Pages

  34. COF series

    6  Pages

  35. CCJ series

    7  Pages

  36. Force logger

    5  Pages

  37. PGC series

    4  Pages

  38. GC-60/100

    4  Pages

  39. FP-50/51

    3  Pages

  40. XST-500N

    4  Pages

  41. FBO-CFX

    3  Pages

  42. grp-50

    3  Pages

  43. SK series

    6  Pages

  44. FCA-DSV-50N

    4  Pages

  45. ZLINK4

    5  Pages

  46. SDT series

    4  Pages

  47. MED-NPT-200N

    4  Pages

  48. MED-ACU-2N

    3  Pages

  49. TKS-20N/250N

    6  Pages

  50. BT series

    6  Pages

  51. SQ series

    4  Pages

  52. CW-500N

    4  Pages

  53. MED-IS-20N

    3  Pages

  54. MED-SCT-500N

    3  Pages

  55. WG series

    5  Pages

  56. SP series

    4  Pages

  57. PG series

    4  Pages

  58. PC series

    4  Pages

  59. P45-50N

    4  Pages

  60. GC-5/15

    4  Pages

  61. CP-150N

    3  Pages

  62. PPC-5000N

    4  Pages

  63. DSV series

    6  Pages

  64. AMK series

    4  Pages

  65. ST-SS

    2  Pages

  66. SJ series

    6  Pages

  67. RSH series

    5  Pages

  68. HFC-50N

    4  Pages

  69. ZW1-10kN

    6  Pages

  70. CW-5000N

    4  Pages

  71. LH-500N

    5  Pages

  72. UK series

    5  Pages

  73. PT series

    6  Pages

  74. PSH series

    5  Pages

  75. PCA-150N

    3  Pages

  76. CH-5000N

    4  Pages

  77. FB/FS series

    5  Pages

  78. PS/PSS series

    5  Pages

  79. PSM series

    5  Pages

  80. SHT-5N

    3  Pages

  81. Force Gauges

    4  Pages

  82. DS2 series

    4  Pages

  83. F-S Master

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.