Catalog excerpts
IMADA CO.,LTD Load cell for compression or tension SK series Load cell for compression or tension SK series The beam shape load cell having a robust body provides easy installation. It allows detailed analysis due to the high accuracy. Simply change the installing direction to switch detecting force. *Install the load cell according to force applied direction. What is IP? IP(International Protection) is a standard which is based on IEC Standard 529 for solid foreign materials, electric devices for water and cabinet. IP67 The second code (IP 0 to 8 for water penetration) The first code (IP 0 to 8 for human body and sold foreign materials) Ingress of water in harmful quantity shall not be possible when the enclosure is immersed in water under defined conditions of pressure and time (up to 1m of submersion for 30 minutes). No ingress of dust; complete protection against contact (dust tight) :eZ-Connect series eZ-Connect is composed of an amplifier and load cells. Enables to replace load cells without additional adjustment. Suitable for different types of tests such as tension and torque, measuring from low load to high load etc. Available load cells have a mark
Open the catalog to page 1IMADA CO.,LTD Load cell for compression or tension SK series Using images Fix the load cell to make its head out from the edge of your facility. Apply and measure force of compression/tension. *It measures either compression or tension. Please decide the load cell direction according to applied force Specifications Model Capacity Accuracy Rated output Nonlinearity Hysteresis Recommended voltage (Allowable applied voltage) Safe overload rating Working environment (Allowable temperature) Temperature influence for 0 point Temperature influence for output Weight Cable Dimensions International...
Open the catalog to page 2IMADA CO.,LTD Load cell for compression or tension SK series Available Amplifiers (Indicators) eZ-Connect series Separated Sensor Model Handy type ZTS series Handy type ZTA series Sensor Interchangeable Amplifier Desktop type Desktop type Handy type - Desktop use - Load cell interchangeable (such as measurement of tension and torque, or low and high load) - Handheld use - Load cell interchangeable (such as measurement of tension and torque, or low and high load) load cell - Handheld use - Specific purpose - Higher accuracy - Handheld use - Specific purpose - Higher accuracy - I/O...
Open the catalog to page 3IMADA CO.,LTD Load cell for compression or tension SK series [Load cell by itself] Model Custom-made Order Extend the length of a cable Enhance flexibility of a cable Enables to extend the length of a cable for gauge-PC connection or load cell-amplifier connection. Enables to offer high-flex cable to reduce risks of disconnection. * Please contact us for details such as cable length etc. [Related products] - Cables Model CB-108 CB-118 CB-208 Explanation Analog cable Analog cable (For -AN option) RS232C cable Open end connection cable Cable with terminal block Purpose of use To connect to a...
Open the catalog to page 4IMADA CO.,LTD Load cell for compression or tension SK series - Other load cell line-up (We offer wide range of load cells to fit your measurement needs.) For door closing Standard type High capacity type Crane scale type and opening force DPU series SW3 series ZW1-10kN SKM-1000N High accuracy built-in type load cell for general use. High capacity waterproof type. High capacity load cell with a hook. Load cell for measuring opening and closing force of doors and windows. Load cell for car foot brakes. *Please refer to each specification for the detail.
Open the catalog to page 5IMADA CO.,LTD Load cell for compression or tension SK series [Cautions] - Information in this document is subject to change without prior notice. - This document is product descriptions and handling precautions, and do not guarantee various characteristics or safety. - This product is designed for force measurement purpose only. - Do not copy and use this content without authorization. - Do not apply force more than its capacity or from incorrect direction to the measuring shaft. - Do not use this product in the environments including fierce temperature changes, high temperature, high...
Open the catalog to page 6All IMADA catalogs and technical brochures
-
Force Recorder Next Series
8 Pages
-
Force Recorder Professional
7 Pages
-
Force Recorder Standard
7 Pages
-
OP-MX2EMX-IC/OP-MX250-IC
4 Pages
-
KC series
4 Pages
-
LM/LC/DD2/LMT series
7 Pages
-
CLFX / CFX Series
5 Pages
-
ZTS series
7 Pages
-
ZTA series
8 Pages
-
FSA series
7 Pages
-
FA Plus2 / eFA Plus2
11 Pages
-
HTGS/HTGA series
8 Pages
-
Specification list of cables
7 Pages
-
LMU/LU/ZD series
7 Pages
-
A-40/60,S-40/60
4 Pages
-
MTS series
7 Pages
-
XY-500N series
5 Pages
-
XST-500N
3 Pages
-
TS-5000N
3 Pages
-
SHF series
5 Pages
-
GTW-2500N
4 Pages
-
CCJ series
6 Pages
-
Vise Grips GT-30/2000N
4 Pages
-
DPU series
7 Pages
-
SKM-1000N
6 Pages
-
PGC series
4 Pages
-
DM-2000N
6 Pages
-
CBJ-200N
4 Pages
-
FBO-CFX
3 Pages
-
COF series
7 Pages
-
PK2-1500N
4 Pages
-
SW series
7 Pages
-
grp-50
3 Pages
-
P180-200N
6 Pages
-
P90‐200N
7 Pages
-
ZU series
6 Pages
-
SCX series
5 Pages
-
CHX Series
6 Pages
-
Pen Type Load Cell PN-50N
4 Pages
-
Torque Load Cell eHT series
5 Pages
-
HTGS/HTGA-TFX Series
8 Pages
-
TFX Series
4 Pages
-
Driver Torque Meter I-8/I-80
4 Pages
-
FCA-DSV-50N
4 Pages
-
IPTS-20N/50N
6 Pages
-
Peeling Tester IPTS-5N
7 Pages
-
SJS-100N-L/S
5 Pages
-
VWF-10N
6 Pages
-
APR-97
3 Pages
-
Force Logger Plus
4 Pages
-
Force Recorder Plus
8 Pages
-
ZLINK4
5 Pages
-
SDT series
4 Pages
-
MED-LFA-20N/MED-VH-5N
4 Pages
-
MED-NPT-200N
4 Pages
-
MED-ACU-2N
3 Pages
-
TKS-20N/250N
6 Pages
-
BT series
6 Pages
-
GC-1100/1200/5000, GCF-1200
5 Pages
-
HV series
5 Pages
-
SQ series
4 Pages
-
CW-500N
4 Pages
-
Force logger
5 Pages
-
MED-IS-20N
3 Pages
-
FC series
6 Pages
-
EMX-1000N
7 Pages
-
MED-SCT-500N
3 Pages
-
WG series
5 Pages
-
GP-15/30
4 Pages
-
GC-60/100
4 Pages
-
FP-50/51
3 Pages
-
SP series
4 Pages
-
PG series
4 Pages
-
PC series
4 Pages
-
P45-50N
4 Pages
-
GC-5/15
4 Pages
-
CP-150N
3 Pages
-
Force gauge comparison table
4 Pages
-
Optional handle FOH
3 Pages
-
FRTS series
6 Pages
-
MS series
5 Pages
-
PPC-5000N
4 Pages
-
DSV series
6 Pages
-
WL01 series
5 Pages
-
Compression attachment table
3 Pages
-
MH2 series
6 Pages
-
PTW-10IN/OT-8IN
3 Pages
-
AMK series
4 Pages
-
Universal Joint UJ series
4 Pages
-
ST-SS
2 Pages
-
SJ series
6 Pages
-
RSH series
5 Pages
-
HFC-50N
4 Pages
-
ZW1-10kN
6 Pages
-
CW-5000N
4 Pages
-
CH-5000N
4 Pages
-
LH-500N
5 Pages
-
UK series
5 Pages
-
PT series
6 Pages
-
FCA-50N
3 Pages
-
PK1-500N series
4 Pages
-
KV series
3 Pages
-
SH series
5 Pages
-
PSH series
5 Pages
-
PCA-150N
3 Pages
-
CH-5000N
4 Pages
-
FB/FS series
5 Pages
-
PS/PSS series
5 Pages
-
PSM series
5 Pages
-
SHT-5N
3 Pages
-
180 degree Peeling Tester
5 Pages
-
Force gauge attachment
5 Pages
-
Force Gauges
4 Pages
-
DS2 series
4 Pages
-
LMU series
8 Pages
-
ZD series
8 Pages
-
F-S Master
5 Pages
-
Friction Testing System
1 Pages
-
Peel testing system
1 Pages
Archived catalogs
-
ZTS series
7 Pages
-
ZTA series
9 Pages
-
Wire Harness Pull Tester
3 Pages
-
FCA-DS2-50N
3 Pages
-
MX-1000N
3 Pages
-
MX-500N
3 Pages
-
HV-3000N
3 Pages
-
MS-50N
4 Pages
-
SV series
4 Pages
-
Tensile Load Cell ZW1-10kN
6 Pages
-
PK1-500N/PK2-1500N
4 Pages
-
FA Plus
4 Pages
-
HV series
3 Pages