0.1
0.25 1 0.75
1
10
5 10
100
Material Wear limit
[°C]
Material
iglidurŪ G +120 iglidurŪ UW500
iglidurŪ J +70 iglidurŪ H
iglidurŪ M250 +80 iglidurŪ H1
iglidurŪ W300 +120 iglidurŪ H370
iglidurŪ X +210 iglidurŪ
iglidurŪ K +90 iglidurŪ A180
iglidurŪ P +100 iglidurŪ A200
iglidurŪ GLW +100 iglidurŪ
iglidurŪ J260 +80 iglidurŪ A500
iglidurŪ J3 +70 iglidurŪ A290
iglidurŪ J350 +140 iglidurŪ
iglidurŪ L250 +120 iglidurŪ F
iglidurŪ R +70 iglidurŪ H4
iglidurŪ D +70 iglidurŪ
iglidurŪ J200 +70 iglidurŪ
iglidurŪ X6 +210 iglidurŪ
iglidurŪ V400 +130 iglidurŪ
iglidurŪ Z +200
igusŪ GmbH 51147 Cologne | Phone +49 (0) 22 03-9649-145 Fax -334 | www.
iglidurŪ G iglidurŪ M250
iglidurŪ J iglidurŪ W300
iglidurŪ G iglidurŪ P
iglidurŪ J iglidurŪ V400
iglidurŪ W300
Pressure [MPa]
Graph 13: Wear of iglidurŪ plain bearings
pressures
Wear [ėm/km]
Pressure [MPa]
Graph 14: Wear of iglidurŪ plain bearings,
v = 0,1 m/s
Table 06: Wear limits of iglidurŪ plain
speeds, the wear resistance can easily vary by a factor of
10 between materials pairings that run well together.
Shaft Materials, page 51
Wear and Pressure
Different loads greatly infl uence the bearing wear. Among
the iglidur plain bearings, certain materials are optimized
for low loads, while others are better suited for high or
extremely high loads.
Wear and Temperature
Within wide temperature ranges, the wear resistance of the
iglidurŪ plain bearings shows little change. In the maximum
temperature range, however, the temperature increases
and the wear of the plain bearing increases. The table on the
following page compares the wear limits. One particular
exception is represented by iglidurŪ X. The wear resistance
of iglidurŪ X increases greatly as temperature increases and
reaches the optimum wear resistance at a temperature of
+ 160 °C. Then resistance decreases again, gradually.
|