499
iglidur®
C
0.0
0.1
0.2
0.3
0.4
0.6
0.8
0 1 2 3 4 5 6 7
0.5
0.7
iglidur® C | Technical Data
igus® GmbH 51147 Cologne | Phone +49 (0) 22 03-9649-145 Fax -334 | www.igus.eu
Reduction of the inner-Ř [%]
Moisture absorption [weight %]
Graph 10: Effect of moisture absorption on plain
bearings
Moisture Absorption
The moisture absorption of iglidur® C plain bearings is
approx. 7 % when saturated in water, and this needs to
be taken into account if this material is to be used in wet
enviroments.
Maximum moisture absorption
At +23 °C/50 % r.h. 1.0 % weight
Max. moisture absorption 6.9 % weight
Table 06: Moisture absorption
Installation Tolerances
iglidur® C plain bearings are meant to be oversized before
being pressfit. The bearings are designed for pressfit into a
housing machined to a H7 tolerance. After being assembled
into a nominal size housing, the inner diameter is adjusted
to meet our specified tolerances.
Testing Methods, page 55
Diameter Shaft h9 iglidur® C Housing H7
d1 [mm] [mm] D11 [mm] [mm]
up to 3 0–0.025 +0.020 +0.080 0 +0.010
> 3 to 6 0–0.030 +0.030 +0.105 0 +0.012
> 6 to 10 0–0.036 +0.040 +0.130 0 +0.015
> 10 to 18 0–0.043 +0.050 +0.160 0 +0.018
> 18 to 30 0–0.052 +0.065 +0.195 0 +0.021
> 30 to 50 0–0.062 +0.080 +0.240 0 +0.025
> 50 to 80 0–0.074 +0.100 +0.290 0 +0.030
Table 07: Important tolerances for plain bearings
according to ISO 3547-1 after pressfit
Product Range
iglidur® C plain bearings are produced to special order.
|