37 Test parameters: Taking into consideration that ST plugs have a mean insertion attenuation of 0,3 dB and a maximum insertion attenuation of 0,5 dB, the increase in attenuation of approx. 0,1-0,15 dB after more than 30 million movements in the E-Chain® is absolutely negligible. Thus the cable has covered more than 76.000 km during the test. The lightwave length considered here is 850 nm. Test cable: igus® Chainflex® CFLG.2HG.MF.50/125 Number of fibres: 2 Type of fibre: Gradient fibre 50/125ìm Connector: 2 x ST Connector Travel: 2 m Length of cable: 3 m Energy chain: igus® E-Chain® series 15.015.100.0 Test radius: 11 x d Attenuation in [dB] Number of individual strokes in [MioH] Maximum permissible attenuation Increase in attenuation as a function of the number of individual strokes