catalogue search
|
You may also be interested in
Video cable, Linear drive unit, Measuring system, Protection hose, Electrical cable assembly
Text version of the page
Attenuation
The maximum values of the individual attenuation for each pair of
cores are specified for the corresponding nominal characteristic
wave impedance in dB/100m in the DIN IEC 61156-6 standard.
Accordingly, the cables are subdivided into several categories according
to the transmission frequency planned to be used. For the
cable being inspected, transmission frequencies of up to 100 MHz
are planned to be used, which corresponds to the category 5e.
Test result
The attenuation, as a measure of the reduction of the transmitted
electrical energy of a signal on the cable, remains, even after more
than 1,5 million double strokes, below the specified limit value while
being subjected to the application of stress of the minimum bending
radius.
The characteristic electrical transmission quantities such as characteristic
wave impedance, return loss and near-end crosstalk are
fulfilled so that, despite applications of high mechanical stress, the
electrical values of the IEC standard are complied with for a cable
of the category 5.
MHz
dB/100 m
27
max. norm value
new condition
according to 332.269 double strokes
according to 686.767 double strokes
according to 1.561.281 double strokes
0 10 20 30 40 50 60 70 80 90 100
0
-5
-10
-15
-20
-25
-30
-35
Product information
CF14 CAT5 page 130
|