Text version of the page
Text version of the page
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Pressure switches and transmitters | | | | | | | | | | | | | | | | mm | | | | | | | | | | | | | | | | | | | | | | | | | | | Measuring range [bar] | Permissible overload pressure | Burst pressure limit | Setpoint [bar] | Reset point [bar] | Resolution steps of [bar] | Output | Order no. | | | | | | | | Electronic pressure sensors PP, M12 connector, Ub: 9.6...30 V DC, PNP/NPN, programmable via EPS interface | | | | 0...400 | 600 | 1000 | 4...400 | 2...398 | 1 | 2 x no / nc | PP7020 | | | | 0...250 | 400 | 850 | 3...250 | 2...249 | 1 | 2 x no / nc | PP7021 | | | | 0...100 | 300 | 650 | 1...99.9 | 0.5...99.5 | 0.1 | 2 x no / nc | PP7022 | | | | 0...25 | 100 | 350 | 0.3...25 | 0.2...24.9 | 0.1 | 2 x no / nc | PP7023 | | | | 0...10 | 50 | 150 | 0.1...9.99 | 0.05...9.94 | 0.01 | 2 x no / nc | PP7024 | | | | 0...2.5 | 20 | 50 | 0.03...2.5 | 0.02...2.49 | 0.01 | 2 x no / nc | PP7026 | | | | | | Programming and display unit for EPS sensors | | | PP2000 | | | | Teach button for EPS sensors | E30051 | | | | | | Service system for programming and reading PP sensors | | ZZ0050 | | | | Electronic pressure sensors PN with 4-digit LED display, M12 connector, Ub: 18...36 V DC, PNP, process connection G 1/4 I | | | | 0...400 | 600 | 1000 | 4...400 | 2...398 | 2 | 1 x no / nc | PN5000 | | | | 0...250 | 400 | 850 | 2...250 | 1...249 | 1 | 1 x no / nc | PN5001 | | | | 0...100 | 300 | 650 | 1...100 | 0.5...99.5 | 0.5 | 1 x no / nc | PN5002 | | | | 0...25 | 150 | 350 | 0.2...25 | 0.1...24.9 | 0.1 | 1 x no / nc | PN5003 | | | | 0...10 | 75 | 150 | 0.1...10 | 0.05...9.95 | 0.05 | 1 x no / nc | PN5004 | | | | 0...2.5 | 20 | 50 | 0.02...2.5 | 0.01...2.49 | 0.01 | 1 x no / nc | PN5006 | | | | 0... 1 | 10 | 30 | 0.01... 1 | 0.005...0.995 | 0.005 | 1 x no / nc | PN5007 | | | | Electronic pressure sensors PN with 4-digit LED display, M12 connector, Ub: 18...36 V DC, PNP/NPN, process connection G 1/4 I | | | | 0...600 | 800 | 1200 | 6...600 | 3...597 | 3 | 2 x no / nc | PN7060 | | | | 0...400 | 600 | 1000 | 4...400 | 2...398 | 2 | 2 x no / nc | PN7000 | | | | 0...250 | 400 | 850 | 2...250 | 1...249 | 1 | 2 x no / nc | PN7001 | | | | 0...100 | 300 | 650 | 1...100 | 0.5...99.5 | 0.5 | 2 x no / nc | PN7002 | | | | 0...25 | 150 | 350 | 0.2...25 | 0.1...24.9 | 0.1 | 2 x no / nc | PN7003 | | | | 0...10 | 75 | 150 | 0.1...10 | 0.05...9.95 | 0.05 | 2 x no / nc | PN7004 | | | | 0...2.5 | 20 | 50 | 0.02...2.5 | 0.01...2.49 | 0.01 | 2 x no / nc | PN7006 | | | | 0...1 | 10 | 30 | 0.01...1 | 0.005...0.995 | 0.005 | 2 x no / nc | PN7007 | | | | | 10 | 30 | -0.97...1 | -0.98...0.99 | 0.01 | 2 x no / nc | PN7009 | | | | Electronic pressure sensors PN with 4-digit LED display, 1/2" UNF connector, Ub: 85...265 V AC, Triac-Outp., process con. 1/4 NPT | | | | 0...400 | 600 | 1000 | 4...400 | 2...398 | 1 | 1 x no / nc | PN4220 | | | | 0...250 | 400 | 850 | 2...250 | 1...249 | 1 | 1 x no / nc | PN4221 | | | | 0...100 | 300 | 650 | 1...99.9 | 0.5...99.5 | 0.1 | 1 x no / nc | PN4222 | | | | 0...25 | 100 | 350 | 0.2...25 | 0.1...24.9 | 0.1 | 1 x no / nc | PN4223 | | | | 0...10 | 50 | 150 | 0.1...9.99 | 0.05...9.95 | 0.01 | 1 x no / nc | PN4224 | | | | 0...2.5 | 20 | 50 | 0.02...2.5 | 0.01...2.49 | 0.01 | 1 x no / nc | PN4226 | | | | 0... 1 | 10 | 30 | 0.01...0.999 | 0.005...0.994 | 0.001 | 1 x no / nc | PN4227 | | | | Electronic pressure sensor PK with two complementary normally open / normally closed outputs, switchpoint setting via two setting rings, M12 connector, Ub: 9.6...32 V DC, process connection G 1/4 A | | | | 11...400 | 600 | 1600 | 20...400 | 12...392 | - | 2 x no / nc compl. | PK6520 | | | | 0...250 | 400 | 1000 | 12.5...250 | 7.5...245 | - | 2 x no / nc compl. | PK6521 | | | | 0...100 | 200 | 1000 | 5...100 | 3...98 | - | 2 x no / nc compl. | PK6522 | | | | 0...10 | 25 | 300 | 0.5...10 | 0.3...9.8 | - | 2 x no / nc compl. | PK6524 | | | | Electronic pressure sensor PK with two normally open outputs and fixed 1 % hysteresis switchpoint setting via two setting rings, M12 connector, Ub: 9.6...32 V DC, process connection G 1/4 A | | | | 11...400 | 600 | 1600 | 20...400 | - | - | 2 x no | PK7520 | | | | 0...250 | 400 | 1000 | 12.5...250 | - | - | 2 x no | PK7521 | | | | 0...100 | 200 | 1000 | 5...100 | - | - | 2 x no | PK7522 | | | | 0...10 | 25 | 300 | 0.5...10 | - | - | 2 x no | PK7524 | | | | | | | | | | | | | | | | | | | Transmitters or sensors with integrated control monitor. Overload protection and high long-term stability due to a ceramic measuring cell. Measuring range up to 600 bar. EPS interface for external programming. | | | | | | | | | | Introduction The ifm pressure sensors have been developed for industrial monitoring system pressure in hydraulic and pneumatic applications. Today we cannot imagine the food industry or hygienic applications without pressure sensors. ifm offers a variety of different types for different industrial applications. All units have one thing in common: They have a one-piece housing and need no moving parts such as pistons or springs. The result: The sensor are extremely robust against mechanical influence and work completely without wear and tear and fatigue. The sensor has a ceramic measuring cell. The advantage of this material is that it is resistant to corrosion and gives long-term stability. In the long run this guarantees a continuous accuracy of the measured values. ifm sensors are also resistant to dynamic pressure peaks and have a high overload resistance. It is of special importance that they are resistant to pressure peaks which usually arise on fast closing valves. Depending on the mounting position pressure peaks as well as vacuum peaks can alternate quickly. Even in these critical situations ifm sensors are resistant. The flush sealing system of the ceramic measuring cell when mounted in the stainless steel housing allows optimum cleaning of the sensor - an absolute must for the use in the food industry or in hygienic applications. A variety of sensor solutions The pressure sensors from ifm are available in various designs, including pressure switches and industrial pressure transmitters. A new unit series monitors the pressure in the food industry and other hygienic applications and meets the 3A, FDA and EHEDG requirements. EPS interface The pressure sensors often have to be mounted at positions in the installation / machine that are difficult to access. Programming and reading of the values on site are difficult. The solution: For these applications ifm offers sensors with EPS interface. Pressure sensor and control monitor are located on site in the sensor housing. Programming is performed using the programming unit (PP 2000) or the PC programming assistant. | | | | | | Separate display/ programming unit PP2000. | | | | | | | | | | The display: The 7-segment display shows the system pressure at a glance. | | | | | | | | | | | | | | | | | | Visit our website: www.ifm-electronic.com | | Visit our website: www.ifm-electronic.com 41 | | | | | | | | | | 40 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|