Notes and explanations Special care must be taken to place the cable into the carriages for the lowerparts to ensure a good contact. The carriages have the same colour code as the flat cable (yellow = AS-i, black = 24 V DC).
Generalinformation Core colours Yellow AS-i cable:A+AS-i plus pole brownA–AS-i minus pole blueBlack auxiliary voltage cable:E+24 V plus pole brownE–24 V minus pole blue After all slaves are correctly connected and addressed, the last step is carriedout. The master must be informed which slaves must be present for a system to operate (list of the projected slaves LPS). This is done by the automatic configuration (for the plc master for example by pressing a button, for ifm controllers conveniently via the menu). In this process the AS-i master briefly passes to the projection mode, reads the current projection of all connected slaves and saves it permanently.
List of articles Controllers / Gateways, network extension Caution: The AS-i minus or plus poles must not be con-nected to ground at any point. Only the shield / GND connection at the AS-i power supply must be ground- ed! Input and output potentials have reference to the related AS-i module. Mixing reference potentials over several modules is not allowed. In the control cabinet the yellow AS-i cable should be laid uninterrupted tothe AS-i power supply. The master is connected in parallel (blue = AS-i–, brown = AS-i+). If further input / output modules are to be used in the con- trol cabinet, separate wiring (spurs) is recommended, starting from the AS-i power supply.
Power supplies manufacturer and earth fault monitors Step 4: Configure the master automatically.
I/O modules for control cabinets

!

I/O modules for field applications Projection mode = master communicates with all slaves, e.g. during com-missioning. Missing slaves are not indicated. Normal operating mode = master only communicates with slaves from theLPS. Missing slaves are indicated.
Safety at Work Finished – that’s all!
AS-i sensors, pneumatic and actuator solutions Connection technology Accessories Technical information and customer service Visit our website: www.ifm-electronic.com

21

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-100
101-150
151-200
201-250
251-282