Temperature sensors

Hazardous dust areas

Category 3D(zone 22 – non-conductive dusts)Hazardous dust areas

3-wire Pt100 class B, ATEXclassification II 3D, 3 m silicone cable.

II 3D IP 67 T 100 °C XPt100 sensor element

Direct connection to control monitors, AS-i modules and Plcs.

Thecompany Dimensions[mm] Measuringrange[°C] Material sensor Connection Sensorelement Accuracyclass Dynamic responsetime T05 / T09[s] Orderno.

Protection rating IP 67 for different applications and measuring ranges.

Category 3D · II 3D IP 67 T 100 °C X · Protection rating IP 67
General information Ø 5 mm-20...803 m, silicone cablePt1006 / 18 stainl. st. (320S17) B TS335A
Inductive sensors Capacitive sensors Electronic cylinderswitches Fail-safeinductiveswitches

Temperature sensors in hazardous areas Accessories Control monitor* with integrated display The temperature sensor monitors temperatures inhazardous areas of -20...80 °C. The Pt100 measuring element to DIN EN 60751 corresponds to the accuracy class B. It is integrated in a stainless steel housing (320S17). Using a wirable connector the sensor can be connected to a standard control monitor type TR instal- led outside the hazardous area. The measured value is then indicated on an LED display that is clearly visible at greater distances. Depending on the control monitor the measured value can be provided as analogue value (0...10 V/ 4...20 mA) or as a binary switching signal for further processing.

Type Description Orderno. Setting rangeswitch point[°C] Analogue outputresolution[°C] Display andswitching status U
b Currentconsumption[mA] I
load Orderno. [V] [mA]
Inductivesensorsfor valves Clamp, Ø 34 mm E10193 M12 connector · output function 2 x -39.5...150–3 digits, 7 segments, 2 x red18...30< 50250 TR7430 M12 connector · output function 4 x
Evaluationsystems Protective cover E30006 -39.8...150–4 digits, 10 segments, 4 x yellow18...28< 90< 500 TR8430 M12 connector · output function 4...20 mA or 0...10 V -39.8...3000.14 digits, 10 segments, yellow20...30< 55250 TR2432
Flow sensors Clamp fitting Ø 6 / 8 / 10 mm –G 1/2 for temperature sensors TS / TT E30018 *The control monitors are only allowed for operation outside hazardous areas.

Connection options The connection to existing control monitors is just as requested as the connection to PLCs or AS-i modules. The indicated Pt100 temperature sensor can be directly connected to AS-i modules with Pt100 inputs.

Industrial pressure sensors

Connectors and splitter boxes

Type Description Orderno.

Common technical data ofthe control monitors

Temperature sensors M12 connector 4-pole, wirable E11504 Electrical design: DC PNP(TR2432: NPN/PNP) Switch point accuracy: ± 0.2 K (TR2432: ± 0.3 K) Accuracy of the analogue output (only TR2432): ± 0.3 K Resolution of the switching output: 0.2 °C (TR2432: ± 0.1 K) Resolution of the analogue output (only TR2432): ± 0.1 K Operating temperature: -25...70 °C M12 connector5-pole, wirable E11506
Networking AS-interface Connectors For scale drawings and connection diagrams please seewww.ifm-electronic.com
Technical informationand customerservice

Visit our website: www.ifm-electronic.comVisit our website: www.ifm-electronic.com

5756

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37