WM44-P V3 / WM44-DRM V3.
2Pages

{{requestButtons}}

Catalog excerpts

WM44-P V3 / WM44-DRM V3. - 1

REFERENCES AND ACCESSORIES Electrical features References Power supply 230 Vac, 50-60 Hz (see Inputs Type of input signal Square, triangular or sinusoidal 1-750 Hz / 5-35 Vdc o 4-24 Vac Input impedance -For connection with Anemo4403 or Namur: 1000 ohm -Direct: 10 k ohm Sensors admitted Anemo4403 V3 sensor -3 wire sensor -Namur -Direct signal (see “type of input signal) QO Led electronics Electronics at the service of industry Other devices of WM44 V3 range Power output for sensors 10 Vdc or 20Vdc +/- 10% 0,5 W (only for panel version) Max. connectable impedance 500 Ohm (4-20mA analogue output) Analogue output resolution 1000 dots Analogue output accuracy 1,5% Compatible anemometers and wind vanes 0103010801 ANEMO4403 V3 PULSES OUTPUT M8 LATERAL General features 0103010802 ANEMO4403 V3 PULSES OUTPUT M8 UNDERSIDE Dimensions See drawings 0103011301 ANEMO5H25 V3 PULSES OUTPUT M12 UNDERSIDE NO FEMALE CONNECTOR Measurements Accuracy (100Hz=100km/h) +/- 1km/h Maximum measurable speed 999 km/h, 999MPH, 99.9 m/s *For other references, please contact us. IED Electronics Solutions S.L. Pol. Plazaola E 6, 31195 Aizoain. Navarra (Spain) www.iedelectronics.com info@iedelectronics.com CA-01060305/8 (07/09/2017) All dimensions and sizes are approximate. Specifications and prices are subject to change without notice. WM44 V3 have a 3-digit wind speed reading in km/h, MPH or m/s. Choosing one of the 3 options is possible at any time by pressing “SELECT”. They admit 2 and 3 wire sensors and have a 10-20 Vdc power output. Wind speed display with 2 alarms Pre-configured to work with Anemo4403 V3 pulses output sensor Adjustable pre-alarm and alarm 4-20mA or 0-10V analogue output upon request

Open the catalog to page 1
WM44-P V3 / WM44-DRM V3. - 2

PROGRAM STEPS Alarms The alarm is triggered when the wind speed reaches or exceeds the programmed value. It includes a configurable delay to prevent the alarm from being triggered by gusts of winds. The alarm is deactivated when the wind speed drops below the programmed value. It also has a configurable delay to prevent the alarm from being deactivated by temporary periods of low-intensity wind. The activation of ALARM2 deactivates ALARM1. When ALARM2 is activated, the reading will blink to warn about the danger. Alarms configuration: Trigger values, polarity, intermittent or continuous...

Open the catalog to page 2

All IED COMPANY catalogs and technical brochures

  1. WIND VANE

    6 Pages

  2. WM-44 SS V3.

    3 Pages

  3. ANEMO5H25 V3

    2 Pages

  4. VT

    2 Pages

  5. AI-2

    2 Pages

  6. SRR4

    2 Pages

  7. SRR4 868

    2 Pages

  8. WM44-SS_EN

    2 Pages

  9. WM44_EN

    2 Pages

  10. WM44-P_RF_EN

    2 Pages

  11. SAG-105WR_EN

    2 Pages

  12. WM44-EVO_EN

    2 Pages