WM44-P_RF_EN - 1

REFERENCES Electrical features References (wind sensor and emitter included) electronics Electronics at the service of industry Communication Type of communication IEEE 802.15.4. ISM 2.4 GHz Range Indoor/Urban: 60 m maximum, 30 m tipically Outdoor/Line-of-sight: 750 m maximum, 200 m tipically Analogue output accuracy 1.5 % General features Dimensions See drawings 01030120131 SET ANEMO4403 V3 + RF MODULE V3 F/SLB + 01030120141 SET ANEMO4403 V3 + RF MODULE V3 F/SLB + ''References with external antenna connector (antenna included in reference) *For other references, please contact us. WM44-P V3 RF WM44 V3 range of IED Electronics. Anemometer display with alarms. Q^Led electronics IED Electronics Solutions S.L. Pol. Plazaola E 6, 31195 Aizoain. Navarra (Spain) www.iedelectronics.com info@iedelectronics.com WM44-P V3 RF has a 3-digit wind speed reading in km/h, mph or m/s. It is configured to work with ANEMO4403 V3 RF + RF MODULE V3. More than one display can work with a Radio-Frenquency set. Several devices can communicate each other in the same area with no risk of interaction or interference. Wind speed display with 2 alarms Only for use with ANEMO4403 V3 RF + RF MODULE V3 Adjustable pre-alarm and alarm RF Communication, according to 802.15.4 standard, 2.4 GHz (worldwide free) 4-20mA analogue output All dimensions and sizes are approximate. Specifications and prices are subject to change without notice.

Open the catalog to page 1
WM44-P_RF_EN - 2

PROGRAM STEPS EXTERNAL ANTENNA RP-SMA WM44-P V3 Connections Label Notes: in DC powered units: - Terminal 1: +Vdc (12Vdc or 24Vdc) - Terminal 3: 0 V Alarms The alarm is triggered when the wind speed value reaches or exceeds the programmed value. It includes a configurable delay to prevent the alarm from being triggered by gusts of winds. The alarm is deactivated when the wind speed drops below the set value. It also has a configurable delay to prevent the alarm from being deactivated by temporary periods of low-intensity wind. The activation of ALARM2 deactivates ALARM1. When ALARM2 is...

Open the catalog to page 2

All IED COMPANY catalogs and technical brochures

  1. WIND VANE

    6 Pages

  2. WM-44 SS V3.

    3 Pages

  3. ANEMO5H25 V3

    2 Pages

  4. VT

    2 Pages

  5. AI-2

    2 Pages

  6. SRR4

    2 Pages

  7. SRR4 868

    2 Pages

  8. WM44-SS_EN

    2 Pages

  9. WM44_EN

    2 Pages

  10. SAG-105WR_EN

    2 Pages

  11. WM44-EVO_EN

    2 Pages