video corpo cad

FL1E
4Pages

{{requestButtons}}

Catalog excerpts

FL1E - 1

• New Remote text display panel • New Extended retentive data memory • New Controllable backlit LCD display • New 4 built-in 5kHz fast inputs • New 4 built-in analog inputs Base Modules Base Module LCD Display FL1E-H12SND Part Number without [licnlav — • New Brighter & higher LCD contrast • EEPROM memory • Password protection • Universal voltages • DIN rail or surface mountable 1. Two year backup duration (typ.) when bettery cartridge or memory/battery cartridge used. 2. When selecting frequency trigger function and up/down counter function 3. 10m when connected to analog input (twisted pair cable) Specifications con't on following page

Open the catalog to page 1
FL1E - 2

Specifications con't Al. Class A for AS-lnterface communication module 2. 8kV (air discharge), 4kV (contact discharge) for AS-lnterface communication module 3. 1 kV (criteria A), 2kV (criteria B) for AS-lnterface communication module 4. For protection against surge noise on DC power supply types (FL1E-H12RCE/B12RCE, FL1E-H12SND, FL1E-H12RCA/B12RCA), use surge absorbers, noise cut transformers, or noise filters. Use of surge protection device (DEHN + SOHNE GmbH + Co. VVT AD 24 Part No. 918 402) is recommended

Open the catalog to page 2
FL1E - 3

www.IDEC.com 800-262-IDEC with LCD Display Base Module Part Number without Display Text Display Part Number Keyboard Display Output Points/ Contact Conguration Isolation Input Voltage Dielectric Strength (between power/input terminals and output terminals) Allowable Voltage Range Maximum Load Current Surge Current Rated Frequency Power Supply Power Consumption Data Transmission Rate Short-circuit Protection Minimum Switching Load Initial Contact Resistance Mechanical Life Mechanical Load Display lifetime Note 2 Electrical Life Backlight lifetime Note 1 Electrical Load General Item Operating...

Open the catalog to page 3
FL1E - 4

Function Blocks Series connection of normally open contacts AND Edge detection with edge evaluation (pos. edge) Parallel connection of normally open contacts Parallel connection of normally closed contacts Edge detection with edge evaluation (pos. edge) & Series connection of normally closed contacts Double changeover contact Connection of closed contact Rated Frequency Allowable Momentary Power Interruption Reverse Polarity Protection Analog Input Points High-speed Input Backup Duration Clock Accuracy Input Signal Input Points Input Error Input Resolution Allowable Voltage Range Input...

Open the catalog to page 4

All IDEC catalogs and technical brochures

  1. PRODUCT GUIDE

    44 Pages

  2. HR6S

    32 Pages

  3. KW2D SERIES

    16 Pages

  4. Katalog FL1E

    16 Pages

  5. FT1A SmartAXIS

    36 Pages

  6. XA series

    7 Pages

  7. HG1X

    3 Pages