E-CON Controller Catalog - IAI - #9

/ 12


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
P. 11
P. 12
Pages:


See other catalogues for IAI

Text version of the page
Cover table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:6.00pt "Arial", sans-serif; } .font2 { font:7.00pt "Arial", sans-serif; } .font3 { font:8.00pt "Arial", sans-serif; } .font4 { font:13.00pt "Arial", sans-serif; } .font5 { font:16.00pt "Arial", sans-serif; } .font6 { font:12.00pt "Arial Black", sans-serif; } .font7 { font:8.00pt "Verdana", sans-serif; } E-Con CC-Link Compliance Type 1 CC-Link is a registered trademark of Mitsubishi Electric Corporation. CC-Link complicance type has become available for the E-Con controllers. The controllers achieve I/O signal transmission to/ from the PLC via CC-Link connection using a dedicated cable (1 cable, 4 leads), so you can design a System requiring less wiring. Caution The controllers are recognized as remote I/O terminais and as such able to perform I/O data communication. (They cannot perform data communication.) I System Structure Truck (maximum length 100 - 1200 m) Master Station Minimum Cable Length between Stations 20 cm <-► •a o \y-sy Terminal Résistance Sensor | Slave Station Terminal Résistance Display Slave Station Controller W} E-Conli '| Slave Station Actuator ■ Interface Spécifications Items Spécifications Number of I/O Points Remote Device 8 dedicated input points/10(11) dedicated output points (*1 ) Remote I/O 10 dedicated input points/13 dedicated output points Communication Standard CC-Link VeM.IO(Certified) Communication Speed 10M / 5M / 2.5M / 625k / 156kbps (Changeover via Rotary Switch) Communication Method Broadcast polling method Synchronization Method Frame synchronization method Coding Method NRZI Transmission Path Format Bus format (comforming to EIA RS485) Transmission Format Comforming to HDLC Error Control Method CRC (X16 + X12+ X5+ X1) Number of Occupied Stations 1 station (remote I/O station) Communication Cable Length Communication Speed (bps) 10M 5M 2.5M 625k 156k Cable Length (m) 100 160 400 900 1200 Connecter (Controller side) MC1.5/5-G-3.81 by Phoenix Contact (*2) ("1)10 points if the input power supply is 24V, and 11 points if the input power supply is 100V/200V. (*2) The cable connecter is a standard accessory (MC1.5-ST-3.81 by Phoenix Contact). ■ Controller View / Model E-Con Model EC0N-n-n-cc-n Number of I/O points: 10 dedicated input points / 13 dedicated output points ® Communication connecter MC1.5-ST-3.81 by Phoenix Contact ® Status LEDs RUN/ SD/ RDI ERR © Rotary switchas for various settings Baud rate setting, station number setting (100/200V spécification}

pageCatalog pdf di En 2012-05-19-10