| | | HyPM® XR Backup Power Module | | |
| | | |
| | | Built on the common platform of HyPM strengths, our UL compliant HyPM XR is further tailored to deliver... RELIABILITY Reduced parts count enabled by proprietary unhumidifi ed stack technology Patent pending control technology > 1000 hour life COST-EFFECTIVENESS Further cost reductions through: • low catalyst loading < 0.6 mg Pt/cm2 • optimized BOP • elimination of humidifi cation sub-system Designed for manufacturability: • low cost single frame platform • high volume components | | |
| | | |
| | | | | | | | | | | | | Module Specifications | | HyPM® XR 4 | HyPM® XR 8 | HyPM® XR 12 | | | | Maximum Power | (kW) | 4.5 | 8.5 | 12.5 | | | | Voltage Range | (VDC) | 30 - 38 | 24 - 38 | 37 - 57 | | | | Maximum Operating Current (A) | 150 | 350 | 350 | | | | Dimensions (L x W x H) | (cm) | 87 x 50 x 32 | 87 x 50 x 32 | 96 x 50 x 32 | | | | | (in) | 34 x 20 x 13 | 34 x 20 x 13 | 38 x 20 x 13 | | | | Volume | (1) | 139 | 139 | 154 | | | | | (gallons) | 37 | 37 | 41 | | | | Mass | (kgs) | 80 | 80 | 90 | | | | | (lbs) | 177 | 177 | 198 | | | | Peak Efficiency | (%) | 55 | 55 | 55 | | | | | | | | | | | | |
| | | |
| | | Time from Idle to Peak Power (s) s 4 s 4 s 4 | | |
| | | |
| | | Power Solutions for Backup Fuel Cell Power Modules Hydrogenics offers power solutions to provide constant voltages of 24 and 48 V for the following products: | | |
| | | |
| | | | | | | | | | | | Nominal Voltage | HyPM XR 4 | HyPM XR 8 | HyPM XR 12 | | | | 24 VDC | | | | | | | 48 VDC | | | | | | | | | | | | | | |
| | | |
| | | Please contact us if you have voltage requirements not shown above. | | |
| | | |
| | | | | | | | | | | | | | | | |