Polyiso Bonded to Coated Glass Facer - Hunter - #1

/ 2


catalogue search
Polyiso Bonded to Coated Glass Facer - Hunter
P. 01
Polyiso Bonded to Coated Glass Facer - Hunter
P. 02
Pages:
Polyiso Bonded to Coated Glass Facer - Hunter


See other catalogues for Hunter
You may also be interested in

Panel, Insulation panel


Text version of the page

H-S

F
LAT P
OLYISO

HIELD

B
ONDEDTO C
OATED

-CG

HUNtER G
LASS F
ACER PRODUCT DESCRIPTION H-Shield-CG is a rigid roof insulation panel composed of a closedcell polyisocyanurate foam core laminated to coated glass fiber mat facers. (Gray) F
EATURESAND B
ENEFITS ·Manufactured with NexGen Chemistry™ - Zero ODP, CFCFree,EPA Compliant· Premium facer improves water resistance and dimensional stability. ·Enhanced performance with cold applied BUR, Modified Bitumenand Fully Adhered Single Ply systems.·Meets FM 4450 and UL 1256 for direct application to metal deckconstruction. P
ANEL C
HARACTERISTICS ·Available in 4'x4' (1220mm x 1220mm) and 4'x8' (1220mm x2440mm) panels in thickness of 1"(25mm) to 4.0" (102mm)·ASTM-C 1289-06, Type II, Class 2, Grade 2, (20 psi) or Grade 3 (25 psi).·UL Classified for Class A Assemblies. ·FM Class 1 approved foam plastic INSTALLATION

B

UILT

U

P

, C

OAL

T

AR

A

ND

M

ODIFIED

B

ITUMEN

S

YSTEMS Each H-Shield-CG panel must be secured to the roof deck withFactory Mutual approved fasteners and plates (appropriate to the deck type). A Hunter approved insulation adhesive can also be used. Butt edges and stagger joints of adjacent panels. Install the roof covering according to the manufacturer's specifications. H-SHIELD-CG THERMAL VALUES
THICKNESSLTTRFLUTE(INCHES) (MM)R VALUE*SPANABILITY 1.00256.002 5/8"

S

INGLE

P

LY

S

YSTEMS Energy Smart Polyiso 1.50389.004 3/8" B
ALLASTED S
INGLE P
LY 1.60419.604 3/8" Each H-Shield-CG panel is loosely laid on the roof deck. Butt edges and stagger joints of adjacent panels. Install the roof covering according to the manufacturer's specifications.
1.704310.304 3/8" 2.005112.104 3/8" 2.506415.304 3/8" M
ECHANICALLY A
TTACHED S
INGLE P
LY S
YSTEMS 2.706916.604 3/8" Each H-Shield-CG panel must be secured to the roof deck with Factory Mutual approved fasteners and plates (appropriate to the deck type). Butt edges and stagger joints of adjacent panels. Install the roof covering according to the manufacturer's specifications.
3.007618.504 3/8" 3.308420.404 3/8" 3.508921.704 3/8" 3.609122.404 3/8" F
ULLY A
DHERED S
INGLE P
LY 4.0010225.004 3/8" Each H-Shield-CG panel must be secured to the roof deck with Factory Mutual approved fasteners and plates (appropriate to the deck type). H-Shield-CG may be adhered to a prepared concrete deck with a full mopping of hot steep asphalt (4'x4' panels required) or a Hunter approved insulation adhesive (4'x4' panel recommended). Butt edges and stagger joints of adjacent panels. Install the roof covering according to the manufacturer's specifications. Approved adhesives include, but are not limited to, the following:· FAS 100· Insta Stik· Olybond· MillenniumSee FM listing for all other adhesive approvals.
*Long Term Thermal Resistance Values are based on ASTM C1289-06 and CAN/ULC S770 which provides for a 15-yeartime weighted average. All PIMAmembers have adopted thisadvanced standard for R-value measurement as of 1/1/03.

888-746-1114 · WWW.HUNTERPANELS.COM