PRODUCT DESCRIPTION H-Shield is a rigid roof insulation panel composed of a closed cellpolyisocyanurate foam core bonded on each side to fiber reinforced facers. F
EATURESAND B
ENEFITS ·Manufactured with NexGen Chemistry™ - Zero ODP, CFCFree,EPA Compliant.·Approved for direct application to steel decks. ·Approved under all major roof covering systems – BUR, Modifiedand Single Ply. P
ANEL C
HARACTERISTICS ·Available in 4'x4' (1220mm x 1220mm) and 4'x8' (1220mm x2440mm) panels in thickness of 1"(25mm) to 4.0" (102mm)·Available in two grades of compressive strengths per ASTM C1289-06, Type II, Class 1, Grade 2 (20 psi), Grade 3 (25 psi). INSTALLATION A
PPLICATIONS

B

UILT

U

P

, C

OAL

T

AR

A

ND

M

ODIFIED

B

ITUMEN

S

YSTEMS ·Constructions requiring FM Class 1 and UL Class A ratings ·Single-Ply Roof Systems (Ballasted, Mechanically Attached, Fully Adhered)·Modified Bitumen Systems ·Built-Up Roofing: Asphalt and Coal Tar Each H-Shield panel must be secured to the roof deck withFactory Mutual approved fasteners and plates (appropriate to the deck type). Maximum 4’x4’ (1220mm x 1220mm) panels of H-Shield may be adhered to a prepared concrete deck with a full mopping of hot steep asphalt. Application by cold adhesion also approved. Butt edges and stagger joints of adjacent panels. Install the roof covering according to the manufacturer's specifications. H-SHIELD THERMAL VALUES
THICKNESSLTTRFLUTE(INCHES) (MM)R VALUE*SPANABILITY Energy Smart Polyiso 1.00"256.002 5/8"

S

INGLE

P

LY

S

YSTEMS 1.50"389.004 3/8" B
ALASTED S
INGLE P
LY S
YSTEMS 1.60"419.604 3/8" Each H-Shield panel is loosely laid on the roof deck. Butt edges and stagger joints of adjacent panels. Install the roof covering according to the manufacturer's specifications.
1.70"4310.304 3/8" 1.80"4610.904 3/8" 2.00"5112.104 3/8" M
ECHANICALLY A
TTACHED S
INGLE P
LY S
YSTEMS 2.50"6415.304 3/8" Each H-Shield panel must be secured to the roof deck with Factory Mutual approved fasteners and plates (appropriate to the deck type). Butt edges and stagger joints of adjacent panels. Install the roof covering according to the manufacturer's specifications.
2.70"6916.604 3/8" 3.00"7618.504 3/8" 3.10"7919.104 3/8" 3.30"8420.404 3/8" F
ULLY A
DHERED S
INGLE P
LY 3.50"8921.704 3/8" Each H-Shield panel must be secured to the roof deck with Factory Mutual approved fasteners and plates (appropriate to the deck type). Maximum 4’x4’(1220mm x 12 20mm) panels of H-Shield may be adhered to a prepared concrete deck with a full mopping of hot steep asphalt. Application by cold adhesion also approved. Butt edges and stagger joints of adjacent panels. Install the roof covering according to the manufacturer's specifications.
3.60"9122.404 3/8" 3.70"9423.004 3/8" 4.0010225.004 3/8" *Long Term Thermal Resistance Foam Core Values are based on ASTM C1289-06 and CAN/ULC S770 which provides for a 15-yeartime weighted average. All PIMAmembers have adopted thisadvanced standard for R-value measurement as of 1/1/03.