Power quality analyzers Brochure
8Pages

{{requestButtons}}

Catalog excerpts

Power quality analyzers Brochure - 1

POWER QUALITY ANAL YZERS PQA series and VEGA78 can record all parameters of voltage, current and power simultaneously in order to achieve an advanced mains monitoring as well as a full analysis of spikes and ickers in a simple and intuitive way. ®

Open the catalog to page 1
Power quality analyzers Brochure - 2

Any company can be subject to a reduction in power quality or to an increase in management costs due to inner or external causes so bringing about damages to electrical equipment. PQA series represents a prompt solution to meet engineers’ requirements in every electrical eld, as regards monitoring single- and three-phase networks with the aim of detecting and solving any problem in power supply systems. Disturbances are featured by one origin (or more than one) and by a series of events transferred to the users. The noise origin is not always or exclusively due to the mains supplier, more...

Open the catalog to page 2
Power quality analyzers Brochure - 3

signals and input currents, so defining load nature. -To display table of events related to voltage (voltage anomalies, fast transients) indicating number, date and time of occurrence as well as voltage -To display table of events related to current (inrush currents) indicating number, date and time of occurrence as well as current limits -To display analysis of power quality in the form of graphics and tables -TRMS voltage measurement/ -TRMS current measurement/ recording (3 inputs + 1 neutral) reactive, apparent powers and energy -Analysis of voltage and current - Dissymmetry of input...

Open the catalog to page 3
Power quality analyzers Brochure - 4

Instrument configuration Analyzer setting Before starting a recording the instrument shows a series of system configurations: 4-wire, 3-wire, single, ARON so giving the user the opportunity to define clamp meter type STD or FLEX, clamp's full scale, system frequency as well as interface with voltage transformers (TV) of the installation under test displaying the value of voltages on the primary side of the transformers themselves. Recorder setting Under this section the instrument permits the user to define any detail for activation of recordings, selection of parameters, type of analysis...

Open the catalog to page 4
Power quality analyzers Brochure - 5

Statistical analysis Inrush currents During a dynamic phase such as the start of motors as well as of uninterruptible power supplies or other applications, measurement of inrush currents aims at properly sizing the installation in order to estimate how other elements such as RCDs and fuses could be affected. PQA models are capable of carrying out recordings of inrush currents with minimum resolution of 10ms whose data can be reported both - The number of detected events event occurrence - Date/Time when event took place - Maximum value of inrush current. Graphs show TRMS values of...

Open the catalog to page 5
Power quality analyzers Brochure - 6

TopView software TopView software is a multifunctio- nal application program capable of managing results measured by sa- fety testers, power quality analyzers As for power quality analyzers permits the following operations: - Instrument setting (system type, - On line display of quantities mea- sured by the instrument (numeri- cal values, waveforms, histograms, saving of instantaneous samplings) - Data transfer from instrument to PC through USB and accurate data analysis with graphs and tables - Creation of professional reports on power quality according to Differential analysis of energy...

Open the catalog to page 6
Power quality analyzers Brochure - 7

Clamp-on power quality analyzer with Bluetooth connection HT9022 HT9022 is a combination of a power quality analyzer, a phase sequence/conformity detector, a clamp meter and a voltage detector in one single handy device. The advanced design of HT9022 ensures reliable and accurate measurements under a wide range of operating conditions. HT9022 is the ideal instrument for troubleshooting power quality problems, calculating power factor correctors, recording energy consumption, recording DC power, etc. Unlike the data loggers that take snapshots of the electrical parameters in regular...

Open the catalog to page 7
Power quality analyzers Brochure - 8

POWER QUALITY ANALYZERS and DATA LOGGERS Model AC TRMS voltage in single phase plants AC TRMS voltage in three phase plants AC TRMS current in single phase plants AC TRMS current in three phase plants AC TRMS voltage, current, power, energy, PF in single phase plants AC TRMS voltage, current, power, energy, PF in three phase plants Neutral to ground voltage DC voltage, current, power Neutral current Phase sequence indication Voltage unbalance (NEG%, ZERO%) Voltage Flicker (Pst, Plt) Measurements by external CTs and VTs Voltage/current waveforms with selectable pages Voltage/current harmonic...

Open the catalog to page 8

All HT catalogs and technical brochures

  1. Catalogue 2O24

    110 Pages

  2. HOT

    8 Pages

  3. NRG

    8 Pages

  4. SUN

    12 Pages

  5. PV-ISOTEST

    4 Pages

  6. MERCURY

    2 Pages

  7. Jupiter

    6 Pages

Archived catalogs