Group: Horiba
Catalog excerpts
LF-F Series Liquid Flow Meter Specification Model Flow Range (g/min) Measurement Range Application Liquid*1 Viscosity*2 Accuracy*3 Linearity Repeatability Response Operating Temperature*5 Temperature coefficiency Operating Pressure*6 Pressure Resistance Pressure Drop*7 Flow Rate Signal Power Supply Leak Integrity Wetted Material Standard Fitting 5 to 100% F.S. All liquids except those corrosive to stainless steel (ex, HCl and HF) ± 0.1%F.S./°C max± 1% Max. 5MPa (as flow meter) / 50 to 300kPa (with piezo control valve) 10MPa (as flow meter) max. 500Pa Analog: 0 to 5 VDC Digital: RS485 +15 V ± 5%, 200 mA -15 V ± 5%, 200 mA -12 3 5 x 10 Pa·m /s (He) SUS316L, Ni 1/8" compression 1/4" compression 1/16" , 1/8" compression fitting, 1/8" VCR type fitting 1/8" VCR fitting 1/4" VCR type type *1 With the LF-F/LV-F Series, flow rate calibration is performed using one specified type of liquid. (Please indicate the type of liquid to be used when ordering the device.) - Liquids containing solid materials cannot be measured. - Please consult us in advance if you plan to use these devices with liquid mixture for which the mixture ratio may vary. - With the LV-F Series, if the liquid to be measured contains particle etc., please install a 0.2 µm (Abs) filter on the primary side. *2 The LV-F Type can be used with a maximum viscosity of 0.01Pa·s depending on the flow rate range. Please consult us in advance if you plan to use this device with high-viscosity liquids. *3 Specification of accuracy, linearity and repeatability is guaranteed against calibrated liquid based on SEMI E561296. *4 It is the specification which is adjusted by Auto-PID function with our piezo control valve. *5 In order to ensure precise measurement, please maintain incoming liquid temperature to be within 10 deg.C lower or 3 deg.C higher than the ambient temperature. *6 Specification of Operating Pressure is the pressure range when liquid viscosity is 0.001Pa·s. *7 Specification of pressure drop is when liquid (with viscosity of 0.001Pa·s) is introduced at 100% F.S. of measurement point. LF-F Series Web Ver.001 Subject to change wit
Open the catalog to page 1All HORIBA STEC catalogs and technical brochures
-
GR-300 Series
1 Pages
-
1000M Series
2 Pages
-
ru1000
4 Pages
-
HF HD-960L
5 Pages
-
CVS-ONE Brochure
4 Pages
-
CEMS
4 Pages
-
Cathodoluminescence H-CLUE
5 Pages
-
Cathodoluminescence F-CLUE
5 Pages
-
HE-960HC
5 Pages
-
CAMSIZER X2 Brochure
12 Pages
-
CAMSIZER P4 Brochure
12 Pages
-
Brochure-TPNA-500
6 Pages
-
AP-370 Series Brochure
12 Pages
-
OMNI TERS Probes
2 Pages
-
NanoRaman Brochure
7 Pages
-
51 series Brochure
6 Pages
-
VULCAN Evo
4 Pages
-
MEDAS
8 Pages
-
OBS-ONE GS
6 Pages
-
MEXA-ONE Brochure
26 Pages
-
CRITERION D507 Series
3 Pages
-
Mass flow Controller & Meter
2 Pages
-
Oil analysis
3 Pages
-
Back number of CSR Reports
13 Pages
-
HORIBA Report
86 Pages
-
Soap Film Flow Meter
1 Pages
-
Analog pressure regulator
1 Pages
-
MI/MV
1 Pages
-
LV-F series
1 Pages
-
Criterion, D200 series
16 Pages
-
Pressure Controller
8 Pages
-
SEC-Z500MGX
16 Pages
-
Fluid Controle Equipment
4 Pages
-
Rasidual Gas Analizer
6 Pages
-
Vaporizers
8 Pages