LA-960 Series - Partica
10Pages

{{requestButtons}}

Catalog excerpts

LA-960 Series - Partica - 1

Laser scattering particle size distribution analyzer LA partica LA-960 HORIBA Explore the future Automotive Test Systems I Process & Environmental I Medical I Semiconductor I Scientific HORIBA

Open the catalog to page 1
LA-960 Series - Partica - 2

HORIBA; proudly introduces the newest r- - - * * breakthrough in particle size technology. Laser Scattering Particle Size Distribution Analyzer Partica LA-960 This latest evolution in the LA series advances scientific knowledge for tomorrow's world through intuitive software, unique accessories, and high performance. The LA-960 continues HORIBA's proud tradition of leading the industry with innovative design.

Open the catalog to page 2
LA-960 Series - Partica - 4

Functional polymers The size of particles greatly influences several factors such as dissolution rate, dosing, bioavailability, and immunotoxic-ity, making it an essential parameter for pharmaceutical and biotechnology applications. From simple inhalers to advanced chemotherapies, particle size affects treatment efficacy. The performance of plastics, such as PET is determined by the molecular weight (i.e., size) of the polymers used to prepare the material. The same sort of analysis is also critical for sealants and adhesives. Particle size influences both capacity and coulombic efficiency...

Open the catalog to page 4
LA-960 Series - Partica - 5

State of the art nanoparticle measurement Measurement range 10 nm - 5,000 um The LA-960 features a wide measurement range to measure every application. The unique optical bench is user-friendly and standard in every LA-960 configuration. The advanced design of the LA-960 allows for easy measurement of nanoparticle applications. NIST-traceable size standards verify that the LA-960 accurately measures peaks as fine as 30 nanometers. 60 - second measurement cycle, even in wet mode This incredible speed is made possible by automatic laser alignment, fully automated liquid handling, and...

Open the catalog to page 5
LA-960 Series - Partica - 6

HORIBA’s Original Optical Design HORIBA's ground breaking optical design perfects the static light scattering particle sizing technique. Advanced Detector Design Feature The MiniFlow minimizes sample and dispersant amounts. This miniaturized circulation system features fill and circulation pumps, ultrasonic probe, and drain valve for fully automated operation. Fraction Cell Feature Always make perfect measurements with computer-controlled laser alignment The alignment process is finished in only a few seconds with HORIBA's innovative approach. The LA-960 is a highly refined particle size...

Open the catalog to page 6
LA-960 Series - Partica - 7

Wet Measurement Sample-to-sample analysis in less than 60 seconds The HORIBA LA-960 wet circulation system is an easy, fast and very powerful dispersion system. The standard wet system offers a full package of a dispersant fill pump, liquid level sensor, circulation pump, 30 W in-line ultrasonic probe, and drain valve, which is all software-controlled for true one-button operation. This advanced design provides highly reproducible particle size results. Automated, powerful dry powder dispersion The LA-960 Powderjet combines several unique and patented features to provide the most...

Open the catalog to page 7
LA-960 Series - Partica - 8

Powderjet Dry Feeder Accessory Laser scattering particle size distribution analyzer Model: LA-960 Measurement Principle Windows is a registered trademark of Microsoft Corporation in the United States and other countries. 5^ When ordering the Powderjet please specify the power requirements for the final destination. ^ Above specifications and functionality are valid only when Powderjet is installed on the LA-960 main unit and controlled using the LA-960 software. ^Manufacturers and models indicated for vacuum, air compressor, computer, monitor, and/or printer are subject to change. ©Air...

Open the catalog to page 8
LA-960 Series - Partica - 9

HORIBA, Ltd. Head Office HORIBA Instruments Inc. Head Office HORIBA Instruments Inc. Edison office Please read the operation manual before using this product to assure safe and proper handling of the product. •The specifications, appearance or other aspects of products in this catalog are subject to change without notice. •Please contact us with enquiries concerning further details on the products in this catalog. •The color of the actual products may differ from the color pictured in this catalog due to printing limitations. •It is strictly forbidden to copy the content of this catalog in...

Open the catalog to page 9
LA-960 Series - Partica - 10

HORIBA Explore the future HORIBA

Open the catalog to page 10

All HORIBA Scientific catalogs and technical brochures

  1. SLFA-60.6000

    4 Pages

  2. PX-375

    6 Pages

  3. NanoRaman

    7 Pages

  4. 51 series

    6 Pages

  5. KiloArc

    2 Pages

  6. PowerArc

    2 Pages

  7. Laqua

    24 Pages

  8. Duetta

    8 Pages

  9. MacroRAM

    2 Pages

  10. PSA300

    5 Pages

  11. CAMSIZER XT

    12 Pages

  12. SZ-100

    4 Pages

  13. XPLORER-NS

    6 Pages

  14. EMIA series

    6 Pages

  15. GD PROFILER

    7 Pages

  16. XGT-7200

    2 Pages

  17. EMGA-921

    4 Pages

  18. EMGA-920

    4 Pages

  19. EMGA-930

    4 Pages

  20. EMIA-V2

    14 Pages

  21. VS-20

    6 Pages

  22. CLUE Series

    6 Pages

  23. XploRA One

    2 Pages

  24. Model H1034B

    2 Pages

  25. VS20

    6 Pages

  26. Forensics

    2 Pages

  27. OpenPlex

    2 Pages

  28. AFM Raman

    2 Pages

  29. MESA-50

    2 Pages

  30. Dual-FL

    7 Pages

  31. Aqualog

    6 Pages

  32. Smart SE

    2 Pages

Archived catalogs

  1. JY 2000 2

    2 Pages

  2. ULTIMA 2

    8 Pages

  3. ICCD

    2 Pages