Duetta
8Pages

{{requestButtons}}

Catalog excerpts

Duetta - 1

HORIBA Scientific TWO tlA/ OM\ Explore the future Automotive Test Systems I Process & Environmental I Medical I Semiconductor I Scientific HORIBA

Open the catalog to page 1
Duetta - 2

A Superior Spectrometer Concept • Two-in-one Fluorescence and Absorbance Spectrometer • UV-Vis-NIR Fluorescence Detection Wavelength Range from 250 to 1,100 nm • Full 3-D Fluorescence EEM Acquisition in Less Than One Second • Best in Class Fluorescence Sensitivity Specification of 6,000:1 RMS for Water Raman • Automatic Correction for Primary and Secondary Inner Filter Effects (IFE) • High Fidelity Molecular Fingerprinting with Unique A-TEEM™ (Absorbance-Transmittance Excitation Emission Matrix) Technology • Millisecond CCD Detection of Entire Fluorescence Spectrum Fluorescence and...

Open the catalog to page 2
Duetta - 3

A New Spectrometer Design Ergonomic, Hands Free, Sample Access Fluorescence and Absorbance Duetta’s two specialized sample detectors collect fluorescence at right angles to the excitation light, and absorbance straight through the sample. Normalized Intensity Integrated FL Intensity (rel. units) Absolute Fluorescence Spectra with Real Time Inner Filter Effect (IFE) Correction IFE limits the linearity of the fluorescence signal at higher sample concentrations due to primary and secondary re-absorption of fluorescence. Duetta’s unique design applies real time IFE correction to obtain absolute...

Open the catalog to page 3
Duetta - 4

Intensity (Counts/µA) Chemistry Life Sciences Materials Research Food Science Earth Sciences Intensity (Counts/µA)

Open the catalog to page 4
Duetta - 5

Intensity (Counts/µA) Intensity (Counts/µA) Peak Emission Intensity vs. Temperature Pyrene in a solution of A-B-A triblock copolymer micelles is solvated in the hydrophobic core solvent environment. 3D EEMs can be shown in contour, waterfall plot, or 2D overlay mode. BSA protein measured from 5 °C to 60 °C and the peak intensity and peak wavelength are plotted vs. temperature of the protein solution. Measured using the SampleSnap-4Pelt 4-position Peltier temperature-controlled cuvette holder. Molecular Binding (FRET) Intensity (Counts/µA) Polymer Aggregation and Structure. Temperature...

Open the catalog to page 5
Duetta - 6

EzSpec Software Apps at your Fingertips From the EzSpec™ launch screen, each App icon intuitively helps you identify and select the analysis you want to perform with a simple point and touch. Widest Range of Spectroscopic Acquisition Modes: • Fluorescence kinetics (emission spectra*lor single point intensities) • Absorbance and % Transmittance (spectra or kinetics) HORIBA izSpec METHOD SETUP Autonomous Acquisition Build/Use a concentration curve 1L Emission Spectra Excitation Spectra Capture Value Standard Apps: • Autonomous Acquisition • Pass/Fail • Build/Use a Concentration Curve •...

Open the catalog to page 6
Duetta - 7

Accessories Optional Sample Holder Trays SampleSnap-WJ: Thermostated and Micro-Stirred Cuvette Sample Tray Self-identifying thermostatable, water jacketed cuvette holder (1 cm) with magnetic micro-stir motor. The sample tray can be installed in seconds without the need of a tool, and provides power for micro-stirrer. Requires, but does not include, external water bath. SampleSnap-1Pelt: Single Cuvette Peltier Holder Sample Tray Self-identifying single cuvette Peltier holder (1 cm) for automated temperature control and ramping from -15 °C to +105 °C, with magnetic micro-stirrer. Sample tray...

Open the catalog to page 7
Duetta - 8

PW EEMs QDot LRET GFP FLIM Our Roots Grow Deep HORIBA has a long history of global leadership in high performance fluorescence research instrumentation. Now, with the introduction of Duetta, HORIBA has perfected an affordable spectrofluorometer that takes advantage of decades of experience in fluorescence. (Think SPEX, Jobin Yvon, SLM, IBH, PTI and HORIBA). HDRIBn.com/Duetta 2008 HORIBA HORIBA Scentifc 1988 SPEX purchased by Jobin Photon Technology International acquired by HORIBA Scientifc http://www.horiba.com e-mail: info.sci@horiba.com HORIBA, Ltd.Japan Head Office 2...

Open the catalog to page 8

All HORIBA Scientific catalogs and technical brochures

  1. SLFA-60.6000

    4 Pages

  2. PX-375

    6 Pages

  3. NanoRaman

    7 Pages

  4. 51 series

    6 Pages

  5. KiloArc

    2 Pages

  6. PowerArc

    2 Pages

  7. Laqua

    24 Pages

  8. MacroRAM

    2 Pages

  9. PSA300

    5 Pages

  10. CAMSIZER XT

    12 Pages

  11. SZ-100

    4 Pages

  12. XPLORER-NS

    6 Pages

  13. EMIA series

    6 Pages

  14. GD PROFILER

    7 Pages

  15. XGT-7200

    2 Pages

  16. EMGA-921

    4 Pages

  17. EMGA-920

    4 Pages

  18. EMGA-930

    4 Pages

  19. EMIA-V2

    14 Pages

  20. VS-20

    6 Pages

  21. CLUE Series

    6 Pages

  22. XploRA One

    2 Pages

  23. Model H1034B

    2 Pages

  24. VS20

    6 Pages

  25. Forensics

    2 Pages

  26. OpenPlex

    2 Pages

  27. AFM Raman

    2 Pages

  28. MESA-50

    2 Pages

  29. Dual-FL

    7 Pages

  30. Aqualog

    6 Pages

  31. Smart SE

    2 Pages

Archived catalogs

  1. JY 2000 2

    2 Pages

  2. ULTIMA 2

    8 Pages

  3. ICCD

    2 Pages