Dual-FL
7Pages

{{requestButtons}}

Catalog excerpts

Dual-FL - 1

Dual-FL World's Fastest Fluorometer Measure absorbance spectra and fluorescence simultaneously ELEMENTAL ANALYSIS FLUORESCENCE FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS PARTICLE CHARACTERIZATION RAMAN SPECTROSCOPIC ELLIPSOMETRY SPR IMAGING

Open the catalog to page 1
Dual-FL - 2

100 Times Faster Data Collection The only simultaneous absorbance and fluorescence system available today! The new Dual-FL is the only instrument to simultaneously measure both absorbance spectra and fluorescence Excitation-Emission Matrices. EEMs are acquired up to 100 times faster than with other instruments. Dedicated software automates correction of inner-filter effects and Rayleigh and Raman scattering lines, enabling rapid extraction of information from simple or complex data sets. Hardware Features • The only true simultaneous absorbance-fluorescence system available • TE-cooled CCD...

Open the catalog to page 2
Dual-FL - 3

Aberration corrected double-grating excitation stray-light performance automatic order sorting Aberration corrected emission spectrograph with TE cooled CCD for rapid emission measurements Reference detector to correct fluorescence detector signals Absorbance detector: emission data acquisition

Open the catalog to page 3
Dual-FL - 4

■ Optimized experiment set-up menus minimize user configuration time ■ Complete NIST-traceable corrected fluorescence spectra automatically generated ■ Spectral and kinetic analysis tools for both absorbance and fluorescence data • Methods and batch protocols for automating multiple sample measurement • Absorbance spectra • Fluorescence emission spectra • Fluorescence emission spectra kinetics • Combined fluorescence emission spectra and absorbance kinetics • Fluorescence excitation-emission matrices (EEMs) • Combined excitation-emission matrices • Single point experiment C:\Documenls and...

Open the catalog to page 4
Dual-FL - 5

Inner-filter effect correction Rayleigh Masking (1 st and 2nd grating orders) V] File Edit View Collect Analysis Plot Column Worhsheet Statistics Image Tools Format Window Help Multivariate Analysis (Parallel Factor Analysis)

Open the catalog to page 5
Dual-FL - 6

World's Fastest Fluorometer 17 Second Conventional Fluorometer Data Acquisition 17 Second Dual-FL Data Acquisition

Open the catalog to page 6
Dual-FL - 7

Fluorescence Hardware Specifications

Open the catalog to page 7

All HORIBA Scientific catalogs and technical brochures

  1. SLFA-60.6000

    4 Pages

  2. PX-375

    6 Pages

  3. NanoRaman

    7 Pages

  4. 51 series

    6 Pages

  5. KiloArc

    2 Pages

  6. PowerArc

    2 Pages

  7. Laqua

    24 Pages

  8. Duetta

    8 Pages

  9. MacroRAM

    2 Pages

  10. PSA300

    5 Pages

  11. CAMSIZER XT

    12 Pages

  12. SZ-100

    4 Pages

  13. XPLORER-NS

    6 Pages

  14. EMIA series

    6 Pages

  15. GD PROFILER

    7 Pages

  16. XGT-7200

    2 Pages

  17. EMGA-921

    4 Pages

  18. EMGA-920

    4 Pages

  19. EMGA-930

    4 Pages

  20. EMIA-V2

    14 Pages

  21. VS-20

    6 Pages

  22. CLUE Series

    6 Pages

  23. XploRA One

    2 Pages

  24. Model H1034B

    2 Pages

  25. VS20

    6 Pages

  26. Forensics

    2 Pages

  27. OpenPlex

    2 Pages

  28. AFM Raman

    2 Pages

  29. MESA-50

    2 Pages

  30. Aqualog

    6 Pages

  31. Smart SE

    2 Pages

Archived catalogs

  1. JY 2000 2

    2 Pages

  2. ULTIMA 2

    8 Pages

  3. ICCD

    2 Pages